• 検索結果がありません。

Support for CoaXPress Detection (CoaXPress 検知対応について)

ドキュメント内 CoaXPress Standard (ページ 52-55)

7 Power over CoaXPress: PoCXP (電源重畳型 CoaXPress: PoCXP)

7.4 Host Requirements (ホスト側条件)

7.4.4 Support for CoaXPress Detection (CoaXPress 検知対応について)

All CoaXPress Hosts shall implement the following requirements.

These requirements apply to each connector.

全ての CoaXPress 対応ホストは以下の要件に従って実装を行うこと<SHALL>。 これらの条件は各コネクタに対して適用される。

The Host shall sense that a PoCXP Device is connected before applying power. It can do this by sensing the Device’s nominal 4k7Ω input resistance “Rs”, in which case it shall use a sense current of between 550μA and 1mA.

Comment: This gives a sensed voltage of 2.46V to 4.94V after allowing for the RC time constant of 0.28s from the 57μF maximum capacitance “Cs” with the 4k7Ω input resistance. The sense current range of the Host is deliberately narrower than that implied by section 7.3.3.1 to give a noise margin to the system.

ホストは電源を実際に供給する前に PoCXP のデバイスを検知する<SHALL>。デバイスがもつ標準入力抵抗 Rs の 4.7kΩを検知することでこれを実行できる<CAN>が,この場合は 550μA~1mA の検知電流を用いること

<SHALL>。

コメント: これは 4.7kΩの入力部抵抗に 57μFの最大静電容量“Cs”の条件にてRC時定数 0.28sを許容した場合に 2.46~

4.94Vの検知電圧を導く。検知電流の範囲はシステムへのノイズマージンを考慮してセクション7.3.3.1で適用され ているものより意識的に狭くしている。

 Once power has been applied to a PoCXP Device, the Host shall monitor the power supply current consumed. If at any time after the initial 0.3s the average current is less than 8mA for 0.5s, the Host shall remove power from the Device.

Comment: This causes power to be removed if the Device or cable is unplugged. It also allows the state machine controlling PoCXP to return to its “Sense” state ready to detect a new Device. The current sensing circuit can also be used to monitor the actual power consumed by the Device, and switch off power should the current exceed certain limits, but this is not a requirement of the specification.

 Once power has been applied to a PoCXP Device, the Host shall monitor the voltage on the

CoaXPress connector. If for more than 20ms this voltage drops to a level indicating that the OCP has tripped, the Host shall remove power from the Device.

 The Host shall specifically be designed not to apply power to the following non-PoCXP Devices:

o Non-PoCXP CoaXPress Device, or analog Device, where the Device has a coupling capacitor as the only load.

o 50Ω or 75Ω load to ground.

o Short circuit to ground.

o Large capacitative load such that the sensed voltage is not tending towards a stable value after 3 RC time constants of 4k7Ω / 57µF.

 The Host shall not exceed the following values while sensing for a PoCXP Device:

o Maximum voltage with no load connected: 7V.

o Maximum short circuit current: 2mA.

 PoCXP デバイスに電源が供給された場合,ホスト側は電流が消費されているかを監視する<SHALL>。最初の 電源供給後 0.3s 経過して,その後 0.5s の間に平均 8mA 未満の電流しか流れない場合は,ホスト側がデバイ スへの電源供給を停止する<SHALL>

コメント: これはデバイスまたはケーブルが接続されていない場合に電源供給を停止する,という機能のために起こるもので ある。PoCXP を制御するステートマシーンが新しく接続されるデバイスを検知するために「検知ステート」に戻ろうと するのも可能とする。電流検知回路はデバイスによって消費される実際の電力も監視することができ<CAN>,ある 上限値を超えると電源をオフにすることもできるが,これは規格の要件ではない。

 PoCXP のデバイスに電源が供給された場合,ホストは CoaXPress コネクタにかかる電圧を監視する<SHALL>。

この電圧があるレベルまで降下し,OCP が動作したことを 20ms 以上示した場合,ホストはデバイスへの電源供 給を停止する<SHALL>。

 ホストは以下に示す PoCXP 非対応デバイスに電源を供給しない設計を行うこと<SHALL>:

o PoCXP 非対応デバイス,結合コンデンサのみが負荷になっているアナログカメラ o GND に対し 50Ωまたは 75Ω負荷のもの

o GND に短絡されているもの

o 4.7kΩ / 57μF の3RC 時定数後に検知電圧が一定の値へ収束しない大きな容量負荷をもつもの

 PoCXP デバイスの検知中は以下の値を超えないようにホスト側に配慮すること<SHALL>。

o 無負荷状態で最大電圧が 7V o 短絡状態で最大電流が 2mA

Figure 10 ― Simplified example state diagram

ホスト 初期化

未知 デバイスを

検出

PoCXP デバイスを

検出

PoCXP デバイス

動作中 接続待機

接続なし

接続監視

(検知電圧変化)

RC タイムアウト

RC電荷時間の確認 (4.7kΩ / 57μF)

4.7kΩ入力抵抗を 検知

0.8s 待機

(0.3s 起動時間 + 0.5s 平均電流)

デバイス動作,したがって 最小電流テストは正常

デバイスへ 電源供給 すべて正常 ヒューズトリップ または(推奨)過電流

または0.5s 平均電流 < 8mA

ヒューズトリップ または

(推奨)過電流

電源供給前 電源供給後

図 10 ― 簡略化された状態遷移図の例

ドキュメント内 CoaXPress Standard (ページ 52-55)