• 検索結果がありません。

英語版 FA A 0158 MELSECQ シーケンサ MELSEC 制御機器 |三菱電機 FA

N/A
N/A
Protected

Academic year: 2018

シェア "英語版 FA A 0158 MELSECQ シーケンサ MELSEC 制御機器 |三菱電機 FA"

Copied!
3
0
0

読み込み中.... (全文を見る)

全文

(1)

[Issue No.]

FA-A-0158

[Page]

1/3

[Title]

Change in the packaging of MELSEC-Q series products (manufactured in April 2014

and after)

[Date of Issue]

February 2014

[Relevant Models]

MELSEC-Q series

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

TECHNICAL BULLETIN

Thank you for your continued support of Mitsubishi programmable controllers, MELSEC-Q series. We will inform you of the change in the packaging of MELSEC-Q series products.

The strength of the packaging remains the same, and there is no impact on the product functions and performance due to this change.

1. Target modules and box sizes

Module Model

Box size

Before change After change

Basic model QCPU Q00CPU

145 (H) × 110 (W) × 53 (D)

[mm]

131 (H) × 124 (W) × 46 (D)

[mm] Q01CPU

High Performance model QCPU

Q02CPU

Q02HCPU

Q06HCPU

Q12HCPU

Q25HCPU

Process CPU

Q02PHCPU

Q06PHCPU

Q12PHCPU

Q25PHCPU

Universal model QCPU

Q00UCPU

Q01UCPU

Q02UCPU

Q03UDCPU

Q04UDHCPU

Q06UDHCPU

Q10UDHCPU

Q13UDHCPU

Q20UDHCPU

Q26UDHCPU

A mode QCPU

Q02CPU-A

Q02HCPU-A

Q06HCPU-A

Analog-digital converter module

Q64AD

Q68ADV

(2)

[Issue No.]

FA-A-0158

[Page]

2/3

[Title]

Change in the packaging of MELSEC-Q series products (manufactured in April 2014

and after)

[Date of Issue]

February 2014

[Relevant Models]

MELSEC-Q series

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

TECHNICAL BULLETIN

Module Model

Box size

Before change After change

Channel isolated analog-digital converter module Q68AD-G

145 (H) × 110 (W) × 53 (D)

[mm]

131 (H) × 124 (W) × 46 (D)

[mm]

Channel isolated pulse input module QD60P8-G

Multichannel high-speed counter module QD63P6

4Mpps capable high-speed counter module QD64D2

Multi function counter/timer module QD65PD2

Positioning module

QD70P4

QD70P8

QD75P1

QD75P1N

QD75P2

QD75P2N

QD75P4

QD75P4N

Positioning module with built-in counter function QD72P3C3

Load cell input module Q61LD

CC-Link IE Controller Network module QJ71GP21-SX

MELSECNET/H network module

QJ72LP25G

QJ72LP25GE

QJ72LP25-25

Serial communication module

QJ71C24N

QJ71C24N-R2

Intelligent communication module QD51

QD51-R24

PROFIBUS-DP module QJ71PB92V

QJ71PB93D

Web server module QJ71WS96

MES interface module QJ71MES96

High speed data logger module QD81DL96

(3)

[Issue No.]

FA-A-0158

[Page]

3/3

[Title]

Change in the packaging of MELSEC-Q series products (manufactured in April 2014

and after)

[Date of Issue]

February 2014

[Relevant Models]

MELSEC-Q series

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

TECHNICAL BULLETIN

Module Model

Box size

Before change After change

High-speed counter module

QD62

140 (H) × 110 (W) × 49 (D)

[mm]

131 (H) × 124 (W) × 46 (D)

[mm] QD62E

QD62D

QD62-H01

QD62-H02

Ethernet interface module QJ71E71-100

MELSECNET/H network module

QJ71LP21G

QJ71LP21GE

QJ71LP21-25

CC-Link/LT master module QJ61CL12

MODBUS® interface module QJ71MB91

MODBUS®/TCP interface module QJ71MT91

FL-net(OPCN-2) interface module QJ71FL71-T

QJ71FL71-T-F01

2. Reason for the change

As part of resource saving activities (ISO 14001), packaging boxes need to be downsized.

3. Date of change

The new boxes will be used for the products manufactured in April 2014 and after.

参照

関連したドキュメント

* Department of Mathematical Science, School of Fundamental Science and Engineering, Waseda University, 3‐4‐1 Okubo, Shinjuku, Tokyo 169‐8555, Japan... \mathrm{e}

The Admissions Office for International Programs is a unit of the Admissions Division of Nagoya University that builds and develops a successful international student recruitment

b Department of Physics, Nagoya University, Nagoya 464-8602, Japan abstract: We present a method to construct symplecticity-preserving renormalization group maps by using the

Customs ( Regional Headquarters ) ( Hakodate, Tokyo, Yokohama, Nagoya, Osaka, Kobe, Moji, Nagasaki, Okinawa ) ( 9 ).. Branch offices ( 68 ) ( 106 ) Customs guard posts (

Building on the achievements of the Tokyo Climate Change Strategy so far, the Tokyo Metropolitan Government (TMG) is working with a variety of stakeholders in

充電器内のAC系統部と高電圧部を共通設計,車両とのイ

: Associations betwwen spectral repre sentation of the surface electromyo gram and fibre type distribution and size in human masseter muscle.. : Motor unit activity and

以上の各テーマ、取組は相互に関連しており独立したものではない。東京 2020 大会の持続可能性に配慮し