• 検索結果がありません。

Dual-energy CT can evaluate both hilar and mediastinal lymph nodes and lesion vascularity with a single scan at 60 seconds after contrast medium injection<Abstract of dissertation>

N/A
N/A
Protected

Academic year: 2021

シェア "Dual-energy CT can evaluate both hilar and mediastinal lymph nodes and lesion vascularity with a single scan at 60 seconds after contrast medium injection<Abstract of dissertation>"

Copied!
3
0
0

読み込み中.... (全文を見る)

全文

(1)

Nagoya City University Academic Repository

学 位 の 種 類 博士 (医学) 報 告 番 号 甲第1464号 学 位 記 番 号 第1050号 氏 名 小川 正樹 授 与 年 月 日 平成 27 年 3 月 25 日 学位論文の題名

Dual-energy CT can evaluate both hilar and mediastinal lymph nodes and lesion vascularity with a single scan at 60 seconds after contrast medium injection

(Dual energy CT を用いた造影後 60 秒 1 回撮影法による肺門縦隔リンパ節 及び病変血流の同時評価の試み)

Acad Radiol. 2012; 19: 1003-10

論文審査担当者 主査: 新実 彰男

(2)

1 Dual-energy CT Can Evaluate Both Hilar and Mediastinal Lymph Nodes and Lesion Vascularity with a Single Scan at 60 Seconds after Contrast Medium Injection

Abstract

Purpose. Contrast-enhanced computed tomography (CE-CT) is the standard imaging

modality for this purpose. It has been reported that scanning soon after contrast material injection (e.g., 30 s) is appropriate for clearly depicting the hilar and mediastinal lymph nodes (LN) (1-5). Therefore, post-contrast scans have been performed twice: at an early and late phase to evaluate vascularity of lesions. It is, however, desirable if both demands could be fulfilled by a single scan. With a dual-energy (DE) CT, different contrast images at low and high tube voltages can be obtained at one time and no significant difference has been reported in image noise and radiation dose between single-energy acquisition and weighted-average 120-kVp DE images generated from a combination of the 80-kVp and 140-kVp images (6). We investigated whether the 80-kVp and weighted-average 120-kVp CT images scanned at 60 s after contrast material (CM) injection using a dual-source CT could substitute for the conventional 120-kVp images obtained at 30 and 100 s.

Materials and methods. Eighty-three consecutive patients with suspected lung cancer

were enrolled. Images were obtained with DE mode (80 and 140 kVp) at 60 s and a conventional 120-kVp mode at 30 and 100 s after CM injection. CT numbers of the pulmonary artery (PA), pulmonary vein (PV), hilar zone LN, and pulmonary lesions were measured. Contrasts between the PA/PV and LN and beam-hardening artifacts were visually evaluated using 5- and 4-point scales, respectively. The degree of enhancement was evaluated on 30-s 120-kVp, 100-s 120-kVp, and 60-s weighted-average 120-kVp images.

Results. The mean differences in attenuation (HU) between the PA/PV and LN on the 30-s

120-kVp, 60-s 80-kVp, and 60-s weighted-average 120-kVp images were 184/155, 130/140, and 84/92, respectively (all p<0.001). The mean contrast scores for the hilar/mediastinal LN were 4.5/4.7, 3.7/4.2, 3.3/3.6, and 2.4/2.5 for these three and for 100-s 120-kVp images, respectively (all p<0.01). The mean artifact scores of the four

(3)

2 images were 1.2, 3.4, 3.6, and 4.0, respectively. On 60-s weighted-average 120-kVp images, 55 of 60 lesions (92%) showed a higher enhancement than on 100-s conventional 120-kVp images.

Conclusion. DECT images scanned at 60 s after CM injection show excellent vessel-LN

contrast and enhancement of lesions and can replace the dual-phase scan protocols.

References

1. Shimoyama K, Murata K, Takahashi M, Morita R. Pulmonary hilar lymph node metastases from lung cancer: evaluation based on morphology at thin-section, incremental, dynamic CT. Radiology. 1997; 203(1):187-95.

2. Kaiser LR, Shrager JB. Video-assisted thoracic surgery: the current state of the art. AJR Am J Roentgenol. 1995; 165(5):1111-7.

3. Yano T, Yokoyama H, Inoue T, Asoh H, Tayama K, Ichinose Y. Surgical results and prognostic factors of pathologic N1 disease in non-small-cell carcinoma of the lung. Significance of N1 level: lobar or hilar nodes. J Thorac Cardiovasc Surg. 1994; 107(6):1398-402.

4. Glazer GM, Gross BH, Aisen AM, Quint LE, Francis IR, Orringer MB. Imaging of the pulmonary hilum: a prospective comparative study in patients with lung cancer. AJR Am J Roentgenol. 1985; 145(2):245-8.

5. Watanabe Y, Hayashi Y, Shimizu J, Oda M, Iwa T. Mediastinal nodal involvement and the prognosis of non-small cell lung cancer. Chest. 1991; 100(2):422-8.

6. Schenzle JC, Sommer WH, Neumaier K, et al. Dual energy CT of the chest: how about the dose? Invest Radiol. 2010; 45(6):347-53.

参照

関連したドキュメント

The objectives of this study were to evaluate the formation of lymphvascular niches in lymph nodes of patients with oral squamous cell carcinoma (OSCC), and investigate the roles

Objectives Although dual-energy (DE) acquisition with conventional 201 Tl myocardial perfusion SPECT has sev- eral advantages such as improved attenuation of the infe- rior wall

Exact controllability for the linear wave equation, with both controls in the interior and on the boundary, has been studied by the author in [6] and feedback laws were

The exact controllability of a semilinear wave equation in a bounded open domain of R n , with controls on a part of the boundary and in the interior, is shown.. Feedback laws

We find the criteria for the solvability of the operator equation AX − XB = C, where A, B , and C are unbounded operators, and use the result to show existence and regularity

27 found that multiple solutions exist for a certain range of ratio of the shrinking velocity to the free stream velocity which again depends on the unsteadiness parameter for

(Furthermore, a bound on the number of elementary matrices can be found that depends only on n, and is universal for all fields.) In the case of fields, this can easily be

A nonempty binary tree can also be regarded as a rooted directed tree graph (arborescence) where the outgoing arcs of each node are labeled by distinct labels from the set { L, R