• 検索結果がありません。

Cerebral ischemic lesions detected With diffusion-weighted magnetic resonance imaging after carotid artery stenting : Comparison of several anti-embolic protection devices

N/A
N/A
Protected

Academic year: 2021

シェア "Cerebral ischemic lesions detected With diffusion-weighted magnetic resonance imaging after carotid artery stenting : Comparison of several anti-embolic protection devices"

Copied!
2
0
0

読み込み中.... (全文を見る)

全文

(1)

Cerebral ischemic lesions detected With

diffusion‑weighted magnetic resonance imaging after carotid artery stenting : Comparison of several anti‑embolic protection devices

著者 Mahmoud Moustafa Mohamed Taha

発行年 2010‑03‑25

URL http://hdl.handle.net/10076/11399

(2)

学 位 論 文 の 要 旨

所 属 三重大学大学院医学系研究科

生命医科学専攻 神経感覚医学講座 氏 名

Mahmoud Moustafa

Mohamed Taha

主論文の題名:

Cerebral Ischemic Lesions Detected With Diffusion-Weighted Magnetic Resonance

Imaging After Carotid Artery Stenting: Comparison of Several Anti-embolic Protection Devices

主論文の要旨

Background and objectives

Percutaneous carotid angioplasty and carotid artery stenting (CAS) has the potential of being minimally invasive, less traumatic, and safer in patients with a high surgical risk, resulting in shorter hospital stays. However, CAS does carry inherent risks of morbidity and mortality.Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging.

Study design

A total of 122 patients underwent 128 protected CAS procedures for treatment of occlusive carotid artery diseases at our institution between January 2001 and December 2005. Of these, 27 patients with incomplete data, who were lost to follow up or who were evaluated with a different MR imaging technique (5 mm slice thickness and 1 mm inter-slice gap) were excluded. The remaining 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. All patients underwent complete neurological examination before, during, immediately after, and at 30 days, 3 months, and 6 months to 1 year after the intervention The transfemoral approach is the standard for percutaneous stenting, but the transbrachial approach was used in 2 patients, and direct carotid puncture was employed in 4 patients due to severe atherosclerosis or tortuosity of the blood vessels. MR imaging was performed before and after the procedures within 4 days using a 1.5 T MR imaging scanner (Signa Horizon Echospeed CV). MR imaging sequences included fast fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted imaging.

(注)2,000字以内にまとめて記入すること。

参照

関連したドキュメント

In addition, early ischemic change in clinical images with matrix sizes of 256×256 and 128×128 processed using three imaging filters (Gaussian, smoothing, unsharp mask) from

In the present study, we evaluated the effectiveness of static/nonfreezing hypothermic preservation of rat hearts in a preservative solution with added AFGP based on our

the pelvic space and prostate size using preoperative magnetic resonance imaging. (MRI) for difficult

7.A Ogura, K Hayakawa, T Miyati, F Maeda: The effect of susceptibility of gadolinium contrast media on Diffusion-weighted imaging and the apparent Diffusion coefficient. Dose MD,

38) Comi G, et al : European/Canadian multicenter, double-blind, randomized, placebo-controlled study of the effects of glatiramer acetate on magnetic resonance imaging-measured

When change occurs in the contact person name, address, telephone number and/or an e-mail address, which were registered when the Reporter ID was obtained, it is necessary to

Reset condition: RESET_N falling; REG_RST=1; Watchdog Timer Expiry 0 IBUSRCB_INT 0 R/CLR This interrupt bit is set when the current from VOUT to VBUS exceeds I RCB(TH). Reset

Pour le traitement non-sélectif et la suppression résiduelle de certaines mauvaises herbes annuelles dans le maïs, appliquer l’herbicide StartUp dans le mélange en réservoir avec