• 検索結果がありません。

Test Procedure for the NCV7691RCLV1GEVB

N/A
N/A
Protected

Academic year: 2022

シェア "Test Procedure for the NCV7691RCLV1GEVB"

Copied!
4
0
0

読み込み中.... (全文を見る)

全文

(1)

12/9/2016 1 www.onsemi.com Test Procedure for the NCV7691RCLV1GEVB

Figure 1: Test Setup Configuration

OPEN1-9 closed by default SHORT1-9 open

by default VBAT

2.1 mm DC

(2)

12/9/2016 2 www.onsemi.com Initial setup

1. Add jumpers OPEN1, OPEN2, … OPEN8

2. Remove jumpers SHORT1, SHORT2, … SHORT8 3. Connect strap S1, remove strap S2

Required Equipment

• Bench Power Supply with Ampermeter

• NCV7691RCLV1GEVB Evaluation Board V2

Test procedure Step 1 (Current regulation):

4. Connect the setup as shown above;

5. Apply a supply voltage, sweep VBAT from 7 V to 18 V 6. Check LEDxxR or LEDxxW regulation

7. Check LED_ERR 8. Check IBAT.

9. Check FLTS (J1, pin4)

Table 1: Desired Results

LEDxxR or LEDxxW all on with constant brightness LED_ERR = off

IBAT ~ 800 mA (Rx1 = 1R5) @ VBAT = 7 – 18 V FLTS = LOW

(3)

12/9/2016 3 www.onsemi.com Test procedure Step 2 (PWM):

1. Apply a supply voltage, VBAT = 12 V 2. Toggle PWM (J1, pin 2) to GND 3. Check LEDxxR or LEDxxW states

Table 2: Desired Results

LEDxxR or LEDxxW off when PWM is shorted to GND

Test procedure Step 3 (LED Short):

1. Apply a supply voltage, VBAT = 12 V 2. Short SHORT1 jumper terminals 3. Remove the short

4. Check LEDxxR or LEDxxW states 5. Check LED_ERR state

6. Check IBAT

7. Check FLTS (J1, pin4) 8. Disconnect VBAT

Table 3: Desired Results

LEDxxR or LEDxxW all off LED_ERR = on

IBAT < 8 mA FLTS = HIGH

(4)

12/9/2016 4 www.onsemi.com Test procedure Step 4 (LED Open):

1. Apply a supply voltage, VBAT = 12 V 2. Open OPEN1 jumper terminal 3. Close the terminal again

4. Check LEDxxR or LEDxxW states 5. Check LED_ERR state

6. Check IBAT

7. Check FLTS (J1, pin 4) 8. Disconnect VBAT

Table 4: Desired Results

LEDxxR or LEDxxW all off LED_ERR = on

IBAT < 8 mA FLTS = HIGH

DC Characteristics

MIN TYP MAX

FLTS LOW 0 1

FLTS HIGH 4 6

参照

関連したドキュメント

At various points during testing you will be prompted to connect the Lower Tester unit to the laptop over USB, reset the device, connect the SMA adaptor etc.. At the end of the test

Check OUT1/2 state Table 2: Desired Results.. OUT1/2 = PWM duty-cycle per Duty

If no precautions are taken, it is likely that the voltage drop at the load cables ends induces a

 If the load does not use local Kelvin sensors, then the output voltage must be measured at the board level, not at the cable ends... Board

False triggers test: Turn the lens away from IR radiating sources (humans and living things). Keep the device stable with your hand. Do this for at least 15seconds. If the LED

Connect the electronic load with high voltage module to the output labeled “400 V, 100 W”.. Connect one of the multimeters in series with the output and load and set it to measure

Check HS, HS_DIAG Table 4: Desired Results. HS

Check AC characteristics of RxDC, CANH, CANL4.