• 検索結果がありません。

Test Procedure for the NCV7451V1GEVB Evaluation Board

N/A
N/A
Protected

Academic year: 2022

シェア "Test Procedure for the NCV7451V1GEVB Evaluation Board"

Copied!
3
0
0

読み込み中.... (全文を見る)

全文

(1)

3/5/2021 1 www.onsemi.com

Test Procedure for the NCV7451V1GEVB Evaluation Board

+ V -

Voltmeter Oscilloscope

1 2 3 4 Dig

+ -

Power Supply

A V

To check VR1/WAKE_OUT

Signal Generator

1 MHz

Figure 1: Test Setup Configuration

(2)

3/5/2021 2 www.onsemi.com Required Equipment

• Oscilloscope

• Bench Power Supply

• Voltmeter

• Signal Generator

• CAN Evaluation Board

Test procedure Step 1 (Low power mode):

1. Connect the setup as shown above 2. Close (short) WDEN_lo

3. Open CANEN_hi 4. Check VR1

5. Check RxDC, CANH, CANL, RSTN 6. Check IVbat.

Table 1: Desired Results

VR1 LED_RSTN off RxDC HIGH CANH OFF CANL OFF IVbat < 0.05 mA

Test procedure Step 2 (Normal mode, CAN recessive):

1. Open WDEN_lo

2. Close (short) CANEN_hi 3. Check IVbat.

Table 2: Desired Results

RxDC HIGH

IVbat = < 2 mA – 12 mA >

LED_RSTN flashing

Test procedure Step 3 (Normal mode, CAN square-wave):

1. Close (short) WDEN_lo

2. Apply Square-wave signal to TxDC (0-5 V, 1 MHz)

3. Check AC characteristics of RxDC, CANH, CANL

4. Check WAKE_OUT

Table 3: Desired Results

RxDC HIGH / LOW IVbat = < 10 mA – 30 mA >

CANH RECESSIVE / DOMINANT CANL RECESSIVE / DOMINANT WAKE_OUT LOW

Test procedure Step 4 (Normal mode):

1. Press SW_WAKE 2. Check WAKE_OUT

Table 4: Desired Results

WAKE_OUT HIGH

(3)

3/5/2021 3 www.onsemi.com DC Characteristics

MIN TYP MAX

VR1 4.9 V 5.0 V 5.1 V

RxDC LOW 0 V 0.4 V

RxDC HIGH VR1 – 0.4 V VR1

WAKE_OUT LOW 0 V 0.4 V

WAKE_OUT HIGH VR1 – 0.4 V VR1

CANH OFF 0.1 V

CANL OFF 0.1 V

CANH RECESSIVE 2 V VR1/2 3 V

CANL RECESSIVE 2 V VR1/2 3 V

CANH DOMINANT 2.75 VR1

CANL DOMINANT 0 2.25 V

AC Characteristics 1 V/div

500 ns/div

CANH-CANL

参照

関連したドキュメント

Figure 4: Comparison of Efficiency for Standard in-house and ONS321G Boards 7.1 (b) Efficiency Comparison of ONS321G Evaluation Board for V drvr = 5V &amp; 10V**. Figure 5:

Test Procedure for the Measurement of Load Regulation parameter using Test Setup 1:1. Connect the test setup as shown on

- Write demanded value to relevant box and press Enter (in this case Voltage amplitude 20 and frequency 1, current with amplitude almost 1A and frequency 1Hz after motor start

Also you can use this jumper to connect a differential probe and measure the voltage drop across the resistor caused by the Gate Fault Current feature.. You may use the double

After the power supply is applied, FlexRay communication should be automatically initialized, what should be signaled by blinking LED1 on both nodes..

Allow evaluation board to run for approximately 1 minute then use Yokogawa to measure input power and power factor.. Calculate the efficiency and

Set the function generator 20 to 30 kHz higher than the switching frequency measured in step 7 of Normal Operation.. Disable the generator’s output and connect it to SYNC and GND

(1) Before making any connections, make sure to set the power supplies for input voltage, controller and the driver voltage at 0V. Also make sure that the load current is