(1)

8/1/2011 - 1 - www.onsemi.com

Test Procedure for the NCP3170BGEVB Evaluation Board

V

COM

1000V 750V MAX

10A

100 mA

FLUKE 45Dual Display Multimeter

V A OHM

V A FREQ AUTO

REL

HOLD dB

MIN 2ND

RATE

POWER

1 A

V

COM

1000V 750V MAX

10A

100 mA

FLUKE 45Dual Display Multimeter

V A OHM

V A FREQ AUTO

REL

HOLD dB

MIN 2ND

RATE

POWER

2.5 V

Agilent E3646A Dual Output DC Power Supply

0-8V,3A/0-20V, 1.5A

12 V 0.2A

1 2

Track

LOW High OV DL

RCL Store View I/O

< VoL >

OUT

LOAD

MODE SET RANGESLEW OPP RCLENTER

SHIFT C B A LEVEL FREQ SW ON

LOCAL

KIKUSUI ELECTRONIC LOAD PLZ164WA

165W 0-150V 0-33A

2.5 V 1.2 A

POWER

The following steps describe the test procedure for all these boards:

Suggested Equipment:

Current limited DC Power Supply (e.g. AGILENT 6645A) ……… 1pc DC Volt-Meter able to measure up to 60 V DC (e.g. KEITHLEY 2000) ……… 2pcs DC Amp-Meter able to measure up to 2 A DC (e.g. KEITHLEY 2000) ………. 1pc DC Amp-Meter able to measure up to 5 A DC (e.g. FLUKE 89 IV)……… 1pc DC Electronic Load (e.g. AGILENT 6060B) ……… 1pc

Test Procedure:

1. Connect the test setup as shown in Figure 1 2. Apply an input voltage, VIN = 5.0-18 Vdc 3. Apply IOUT(load) = 0 A

4. Ensure the EN SIP Header is not shorted 5. Check that VOUT = 0V Vdc

6. Short EN SIP Header with provided jumper

7. Observe Soft and PG signal proper behavior as shown in Figure 2 8. Check that VOUT = 3.3 + 5% Vdc

9. Set IOUT to desired level, 0A - 3A, and measure voltage and current - the efficiency should be similar to that shown in Figure 3 and 4

10. Check that VOUT = 3.3 + 5%Vdc under desired operating condition 11. Turn off the load

12. Turn off VIN

13. End of the test

(2)

8/1/2011 - 2 - www.onsemi.com Figure 2: NCP3170B Startup and Regulation with PG Indication

Figure 3: NCP3170 Efficiency at 5V Input and 1.2V, 1.8V, and 3.3V Output

(3)

8/1/2011 - 3 - www.onsemi.com Figure 4: NCP3170 Efficiency at 12V Input and 1.2V, 1.8V, and 3.3V Output

参照

関連したドキュメント

False triggers test: Turn the lens away from IR radiating sources (humans and living things). Keep the device stable with your hand. Do this for at least 15seconds. If the LED

*Note – Be carefully if any device is connected on output, because leakage current can affect measurement accuracy... Apply voltage at

Connect the electronic load with high voltage module to the output labeled “400 V, 100 W”.. Connect one of the multimeters in series with the output and load and set it to measure

Check HS, HS_DIAG Table 4: Desired Results. HS

Check AC characteristics of RxDC, CANH, CANL4.

Connect the mating connector for the output voltage (J2) to the EVB and the other end to an electronic load capable of sinking at least 40 A, which is greater than the typical

“VAC_CONNECTOR”. 6) The digital power meter is connected at the input with the current meter in series with the supply and voltage meter across the input terminals as shown in

The ac-supply pre-regulator demo board is a universal input, off-line, 15-W output, constant voltage power supply for powering E-meters or white goods applications.. This