Test Procedure for the NCP1423EVB

05/19/2005

Figure 1: Equipment Connection Diagram

(2)

Table 1: Required Equipment

Oscilloscope (optional) Ammeter (DMM

1

) Voltmeter (DMM

2

) DC Power Supply One NCP1423 Evaluation Board Electronic Load

Test Procedure:

3.3V Output Version 1. Setup the Equipments

Set the power supply voltage to 2.5 V.

Set the electronic load loading current to 50 mA.

DMM1 (A) as ammeter, measures the input current (IIN).

DMM2 (V) as voltmeter, measures the output voltage (VOUT).

2. Connect the equipment and the demo board. (Figure 1)

Connect a power supply with 4-wire sensing across VBAT and GND.

Connect an electronic load across VOUT and GND.

3. Setup the Demo Board Jumpers. (Refer to table on board) Remove the jumper link from:

JP1 to Enable the device JP2 to Enable Auto Discharge 4. Measuring Result:

a. For IOUT = 50 mA, measure VOUT= 3.15 V to 3.45 V

IIN = 70 mA to 80 mA

b. For IOUT = 350 mA, measure VOUT = 3.15 V to 3.45 V

IIN = 490 mA to 540 mA 5. LBO Test

Set VBAT low, between 1.1 V and 1.3 V; measure the voltage at LBO pin. LBO voltage status will change from Low to High as VBAT is changed from low to high.

(3)

6. ADEN Test

With very small or no load, set the ADEN pin (JP2) to enable. Measure the output voltage waveforms or the time it takes for VOUT to discharge on the voltmeter. Repeat for ADEN disabled. The output voltage discharge time should be faster when ADEN is enabled then when it is disabled.

参照

関連したドキュメント

*Note – Be carefully if any device is connected on output, because leakage current can affect measurement accuracy... Apply voltage at

Board Window: Check Status bits and Motor Current and Supply.. Table 5: Desired Results

Equipment needed: Power supply #1 for +5V power, 1A capability; power supply #2 for input voltage, variable from ~6 V to 25 V, minimum 3 A capability; oscilloscope, minimum of

Connect the electronic load with high voltage module to the output labeled “400 V, 100 W”.. Connect one of the multimeters in series with the output and load and set it to measure

Check HS, HS_DIAG Table 4: Desired Results. HS

Check AC characteristics of RxDC, CANH, CANL4.

Connect the mating connector for the output voltage (J2) to the EVB and the other end to an electronic load capable of sinking at least 40 A, which is greater than the typical

“VAC_CONNECTOR”. 6) The digital power meter is connected at the input with the current meter in series with the supply and voltage meter across the input terminals as shown in