国立医薬品食品衛生研究所 e-mail: nuchiyama@nihs.go.jp ―Note―

薬物簡易スクリーニングキットを用いた

危険ドラッグ成分である合成カンナビノイドの識別法の検討

内山奈穂子,花尻(木倉)瑠理,袴塚高志

Evaluation of an On-site Drug-testing Device for the Detection of

Synthetic Cannabinoids in Illegal Herbal Products

Nahoko Uchiyama,Ruri Kikura-Hanajiri, and Takashi Hakamatsuka

National Institute of Health Sciences (NIHS); 1181 Kamiyoga, Setagaya-ku, Tokyo 1588501, Japan.

(Received October 15, 2014; Accepted November 30, 2014; Advance publication released online January 19, 2015)

Recently, illegal herbal or liquid products containing psychoactive compounds have been a serious problem damag-ing human health and causdamag-ing numerous tra‹c accidents. Reports indicate that most of those herbal products contain various types of synthetic cannabinoids. There are many on-site drug-testing devices; however, synthetic cannabinoids are not targeted compounds for such devices. In this study, we evaluated the on-site drug-testing device ``K2/Spice Test'' for the detection of 12 diŠerent types of 38 synthetic cannabinoids(including 13 naphthoylindole-type synthetic can-nabinoids) and a natural cannabinoid (D9-tetrahydrocannabinol). Although this device is primarily used for the

detec-tion of metabolites of naphthoylindole-type synthetic cannabinoids in urine samples, we applied it to detect synthetic cannabinoids in illegal herbal products for rapid screening analyses. As a result of the on-site examination of synthetic cannabinoids, 10 naphthoylindole-type synthetic cannabinoids [ˆve narcotics (JWH-018, JWH-073, AM-2201, MAM-2201, and JWH-122); ˆve designated substances (JWH-015, JWH-200, AM-1220, JWH-019, and JWH-020)], and two other types of synthetic cannabinoid [designated substances (a benzoylindole AM-694 and a naphthoyl-naphthalene CB-13)] showed positive results (the limit of detection ranged from 50 to 250mg/mL). Furthermore, MeOH extracts of illegal herbal products containing naphthoylindole-type synthetic cannabinoids also showed positive results(the limit of detection ranged from 2.5 to 10 mg herbal products/mL). Therefore, we found that this device may be useful for the on-site examination of some naphthoylindole-type synthetic cannabinoids not only in urine samples but also in illegal herbal products.

Key words―synthetic cannabinoid; drug-screening device; illegal drug; naphthoylindole; immune assay; designer drug 緒 言 2009年頃から,いわゆる「脱法ハーブ」や「リ キッドアロマ」などと呼ばれる危険ドラッグ(違法 ドラッグ)製品の流通が増加しており,これら危険 ドラッグ(いわゆる脱法ドラッグ)に起因すると考 えられる健康被害や自動車事故等が問題となってい る.これら危険ドラッグ中の成分として,今まで に,主に合成カンナビノイド,カチノン類,フェネ チルアミン類,トリプタミン類,ピペラジン類や亜 硝酸エステル類などが検出されている.1,2) これら危険ドラッグのうち,特に,大麻様作用を 標榜したいわゆる「脱法ハーブ」製品中から検出さ れた“合成カンナビノイド”は,2009 年以降急激 に増加し,日本国内だけでもこれまでに数十種類以 上が検出されている.1,2)このうち,JWH-018 を始 めとした naphthoylindole 骨格の化合物は多くのア ナログが検出されているが,1,2)大麻の主活性成分で ある麻薬 D9-tetrahydrocannabinol(D9-THC)と骨 格が大きく異なるにもかかわらず,カンナビノイド 様作用を有することが報告されている.13)また, これら化合物の多くは,麻薬又は指定薬物として随 時規制されており,2014 年 9 月までに 8 種の合成 カンナビノイド(cannabicyclohexanol, JWH-018, JWH-073, JWH-122, AM-2201, MAM-2201,

(2)

XLR-11, 5-Fluoro-QUPIC)が麻薬として規制され ている.指定薬物としては,2014 年 9 月時点で, 2013 年 5 月に包括指定された naphthoylindole 類 759物質を含め 828 種類の合成カンナビノイドが規 制されている(指定薬物 計 1414 物質のうち).し かし,依然として新たな化合物が次々と危険ドラッ グ製品から検出されており,これら化合物の迅速な 規制が必要であると考えられる. 救急医療機関等では,簡易的に乱用薬物を識別す る際に,簡易薬物スクリーニングキットが使用され ている.生体試料中の薬物及び代謝物を検出するた めに,既存のキットとして主に Triage DOA(シ メックス社)や INSTANT-VIEW M-1(TFB 社) などが使用されるが,いずれも合成カンナビノイド は対象となっていない.一方,近年,新しく,主に naphthoylindole 型合成カンナビノイド(JWH-018, JWH-073等)の代謝物を検出対象薬物とした簡易

スクリーニングキット DrugCheck K2/Spice Test (Express Diagnostics 社)が市販されるようになっ た.本キットは,JWH-018 及び JWH-073 の主代 謝物に特異的なモノクローナル抗体を用いたイムノ アッセイキットであり,本来尿試料中の対象薬物の 代謝物の検出を目的として使用するものである.本 キットのデータシートに記載されている代謝物の検 出範囲は 255000 ng/mL である.特に,JWH-018 及 び JWH-073 の 主 代 謝 物 で あ る JWH-018 pen-tanoic acid及び JWH-073 4-butanoic acid のカット オフ値は,それぞれ 50 ng/mL 及び 25 ng/mL と なっているが,未変化体 JWH-018, JWH-073 また その他合成カンナビノイドについての検出限界の記 述はない.そこで,本研究では,危険ドラッグ製品 自体の簡易スクリーニング法に本キットが使用でき ないかを検討するために,12 種類の異なる骨格の 合成カンナビノイド 38 化合物(麻薬:8 化合物, 指定 薬 物: 28 化合 物 ,未 規 制: 2 化合 物 ,う ち naphthoylindole 型:13 化合物)及び大麻の主活性 成分 D9-THC(麻薬)の計 39 化合物を対象として 本キットを用いた検出法を評価するとともに,いわ ゆる“脱法ハーブ”中に含まれる合成カンナビノイ ドの検出に応用し,その有用性を検討した. 実 験 方 法 1. 試料及び試薬 使用した化合物は,合成カ ンナビノイド 38 化合物(麻薬:8 化合物,指定薬 物:28 化合物,未規制:2 化合物)及び D9-THC の計 39 化合物である.化合物は,Cayman Chemi-cal社製,若しくは国立医薬品食品衛生研究所にて 製 造 又 は 単 離 精 製 し た も の を 用 い , D9-THC は Cerilliant社製を用いた.また,危険ドラッグ製品 については,インターネットを通じて入手した植物 系危険ドラッグ 10 製品(危険ドラッグ成分未検出: 2製品,合成カンナビノイド含有:8 製品)及び, 向精神活性植物として流通している「ダミアナ」1 製品 を 用い た .薬 物ス ク リー ニン グ キッ トは , DrugCheckK2/Spice Test (Express Diagnostics 社) を用いた.

2. 試料溶液の調製

2-1. 化合物試料の調製 各化合物を MeOH

に溶解した後,非イオン性界面活性剤 Emulphor EL-620 (GAF Chemical, Wayne, NJ)を添加し攪拌 した . さら に 水を 加え て 試料 溶液 と した [10 % MeOH/2% Emulphor/88% water(v/v)].試料溶 液は適宜希釈し,最終薬物濃度を 1000, 500, 250, 100, 50, 25, 10mg/mL とした.また,化合物未添加 の溶 液 をブ ラ ンク とし て 用い た. な お, 高濃 度 (1000, 500 又は 250 mg/mL)で陰性であったもの は,より低濃度での検討は行わなかった. 2-2. 植物試料の調製 乾燥植物細片 50 mg に MeOH(500 mL)を添加し,超音波下 10 分間抽出 を行った後,MeOH 抽出液(50 mL)に Emulphor (10 mL)を添加し攪拌した.さらに水(440 mL)を 加えて試料溶液とした[10% MeOH/2% Emulphor/ 88% water(v/v)].危険ドラッグ成分未検出の 2 製品及び「ダミアナ」として入手した 1 製品は, JWH-018添加又は未添加 MeOH 溶液を用いて抽出 を行った.最終薬物濃度を 1000, 500, 250, 100, 50, 25mg/mL とした.また,JWH-018 未添加の植物試 料溶液をブランクとして用いた.また,合成カンナ ビノイド含有危険ドラッグ製品については,最終製 品濃度を 10, 5, 2.5, 1.25 mg/mL とした. 3. 簡易スクリーニングキットの操作及び薬物判 定 各試料溶液(500 mL)に,蓋を外したキット の先端を浸し溶液を展開させる.再度蓋を装着した

(3)

Table 1. Analytical Conditions of the K2/Spice Test Kit Condition Compound (conc.) Solvent

1 JWH-018(1 mg/mL) 100% MeOH 2 JWH-018(1 mg/mL) 100% DMSO

3 JWH-018(1 mg/mL) 50% MeOH/50% water 4 JWH-018(1 mg/mL) 50% DMSO/50% water 5 JWH-018(1 mg/mL) 20/78% water% MeOH/2% Emulphor 6 JWH-018(1 mg/mL) 20% MeOH/4% Emulphor/76% water 7 JWH-018(1 mg/mL) 10/88% water% MeOH/2% Emulphor

後,出現するバンドの有無を目視判定した.Con-trol バンド(上部)があらわれ,test バンド(下部) があらわれない場合を陽性と判定し,両バンドがあ らわれる場合は陰性と判定した.4)はじめに,全化 合物について最終薬物濃度 1000, 500 及び 250 mg/ mLで検討を行った.これら濃度で陽性を示したも のは,さらに 100, 50, 25 及び 10 mg/mL まで検討 を行い,陽性を示した最低濃度を検出限界とした. また,合成カンナビノイド含有危険ドラッグ製品に ついては,最終製品濃度 10, 5, 2.5, 1.25 mg/mL で 検討を行い,陽性を示した最低濃度を検出限界とし た. 結果及び考察 1. 試料溶液の条件検討 本キットは,本来尿 試料(水溶性)を対象としているが,多くの合成カ ンナビノイドは脂溶性が高いため,水などの極性溶 媒に溶け難い.そこで,有機溶媒を用いた試料溶液 が適応可能かどうかを検討した(Table 1).各条件 において,JWH-018(最終濃度:1 mg/mL)を用 いた.100%MeOH 又は DMSO に溶解させた試料 溶液については,試料を展開することができなかっ た(条件 1, 2).次に 50%MeOH 又は DMSO 水溶 液に溶解させた試料溶液については,化合物を有機 溶媒で溶解後,水を添加した際に化合物が析出し, 白濁した.また,試料の展開はできたが,control 及び test の 2 つのバンドがあらわれ,陰性を示し た(条件 3, 4).したがって,有機溶媒のみ,又は, 有機溶媒と水のみの混合溶液は試料溶液として不適 であることが分かった.そこで,脂溶性物質の可溶 化に用いられる界面活性剤を添加することを試み た.今回,動物に投与する試料溶液に,合成カンナ ビノイドの可溶化剤(乳化剤)としての使用が報告 さ れ て い る 非 イ オ ン 性 界 面 活 性 剤 Emulphor EL-620(ポリオキシル -35 ヒマシ油)を用いて検 討することとした.5)また,既報での Emulphor の 混合比率は 5%であったため,5)混合比率を 5%以下 として検討を行った.20% MeOH/2% Emulphor/ 78% water 溶液では,化合物が若干析出したものの 後に溶解し,試料溶液は陽性を示した(条件 5). また,20% MeOH/4% Emulphor/76% water 溶液 では,若干 test のバンドがみられた(条件 6).さ らに,10% MeOH/2% Emulphor/88% water 溶液 では,control バンドのみが鮮明にあらわれ,試料 溶液は陽性を示した(条件 7).また,同条件でブ ランク(化合物未添加溶液)は陰性を示すことを確 認した.したがって,本キットは,各化合物の試料 溶液を条件 7 で調製し,検討することとした.ま た,試料液量は,最低量 200 mL で測定が可能で あったが,今回は 500 mL とした.判定に要する時 間は 35分程度であった. 2. 各化合物試料溶液を用いた検討 検討した 化 合 物 の 構 造 式 を Fig. 1 に 示 し た . 12 種 類 (Group AL)の異なる骨格の合成カンナビノイド 38 化合物(麻薬:8 化合物,指定薬物:28 化合物, 未規制:2 化合物)及び D9-THC(Group M)の計 39化合物を用いて検討を行った(Table 2: No. 1 39, Fig. 1). その結果,naphthoylindole 型 10 化合物,その他 2 化合物の計 12 化合物が陽性であった(検出限界 濃度 50250mg/mL)(Table 2: No. 18, 1214, 16). Naphthoylindole型(Group A)13 化合物のうち,

10 化合物が陽性であった(Table 2: No. 18, 12, 13). こ の う ち , 2014 年 9 月 現 在 麻 薬 で あ る naphthoylindole 型 の 5 化 合 物 [ JWH-018, JWH-073, AM-2201, MAM-2201(いずれも≧50mg/ mL),JWH-122(≧100 mg/mL)]はすべて検出可 能であった(Table 2: No. 15).指定薬物について は,naphtoylindole の置換基 R1がノルマルアルキ ル鎖である JWH-015, JWH-019(いずれも≧50 mg/ mL),JWH-020 (≧100mg/mL),morpholinoethyl 基である JWH-200,及び(1-methylpiperidin-2-yl) methyl 基である AM-1220(いずれも≧50mg/mL) は陽性であり,R2=H 又は CH3(JWH-015)では 陽性であった(Table 2: No. 68, 12, 13).一方,R3

(4)
(5)

Table 2. Screening of Synthetic and Natural Cannabinoids Using the K2/Spice Test Kit

No. Group Type Legislationa Compound Limit of detected conc.b 1 A Naphthoylindoles Narcotic JWH-018 +(50 mg/mL) 2 Narcotic JWH-073 +(50 mg/mL) 3 Narcotic JWH-122 +(100 mg/mL) 4 Narcotic AM-2201 +(50 mg/mL) 5 Narcotic MAM-2201 +(50 mg/mL) 6 Designated substance JWH-015 +(50 mg/mL) 7 Designated substance JWH-200 +(50 mg/mL) 8 Designated substance AM-1220 +(50 mg/mL) 9 Designated substance EAM-2201 -(1000 mg/mL) 10 Designated substance JWH-213 -(1000 mg/mL) 11 Designated substance JWH-182 -(1000 mg/mL) 12 Designated substance JWH-019 +(50 mg/mL) 13 Designated substance JWH-020 +(100 mg/mL) 14

B Benzoylindoles Designated substance AM-694 +(50 mg/mL) 15 Designated substance RCS-4 -(1000 mg/mL) 16 C Naphthoylnaphthalenes Designated substance CB-13 +(250 mg/mL) 17

D Phenylacetylindoles Designated substance JWH-250 -(1000 mg/mL) 18 Designated substance Cannabipiperidiethanone -(1000 mg/mL) 19

E Cyclopropylindoles Narcotic XLR-11 -(1000 mg/mL) 20 Designated substance A-834735 -(1000 mg/mL) 21 F Naphthoylpyrroles Designated substance JWH-307 -(1000 mg/mL) 22

G Naphthoylindazoles

Designated substance JWH-018 indazole ana-log (THJ-018) -(1000 mg/mL) 23 Designated substance AM-2201 indazole analog(THJ-2201) -(1000 mg/mL) 24 H Naphthoylbenzimidazoles Designated substance AM-2201 benzimidazoleanalog (FUBIMINA) -(1000 mg/mL) 25

I Carboxyindoles ― Mepirapim -(1000 mg/mL) 26 Designated substance AB-001 -(1000 mg/mL) 27

J Carboxyamide derivatives

Designated substance APICA -(1000 mg/mL) 28 Designated substance AB-PINACA -(1000 mg/mL) 29 Designated substance AB-FUBINACA -(1000 mg/mL) 30 Designated substance ADB-FUBINACA -(1000 mg/mL)

31 ― AMB -(1000 mg/mL)

32 Designated substance 5Fluoro-AMB -(1000 mg/mL) 33 Designated substance NNEI(MN-24) -(1000 mg/mL) 34 Designated substance NNEI indazole analog(MN-18) -(1000 mg/mL) 35

K Quinolinyl carboxylates

Designated substance QUPIC (PB-22) -(1000 mg/mL) 36 Narcotic 5Fluoro-QUPIC(5Fluoro-PB-22) -(1000 mg/mL) 37 Designated substance FUB-PB-22 -(1000 mg/mL) 38 L Cyclohexylphenols Narcotic Cannabicyclohexanol -(1000 mg/mL) 39 M Natural cannabinoids Narcotic D9-THC -(1000 mg/mL) 40 Illegal herbal product-A (no detec-tion of any psychoactive substance) Addition of JWH-018(product only: negative) +(50 mg/mL) 41 Illegal herbal product-B(no detec-tion of any psychoactive substance) Addition of JWH-018(product only: negative) +(50 mg/mL) 42 Illegal herbal product-C(no detec-tion of any psychoactive substance) Addition of JWH-018(product only: negative) +(50 mg/mL)

(6)

Table 3. List of Detected Compounds in the Herbal Productsa Product No. Form Cannabicy-clohexanola (mg/g) JWH-018a (mg/g) JWH-250 a (mg/g) JWH-073 a (mg/g) JWH-015 a (mg/g) JWH-200 a (mg/g) Oleamide a

(mg/g) compoundsOther a Product c (mg/mL) 1 Dried leaf(cutting) n.d.b 35.90±1.05 n.d. n.d. n.d. n.d. n.d. n.d. +(2.5)

2 Dried leaf(cutting) 4.11±0.12 16.37±0.75 n.d. n.d. n.d. n.d. n.d. a-Tocopherol +(10) 3 Dried leaf(cutting) n.d. 13.54±0.50 n.d. n.d. n.d. n.d. 141.58 a-Tocopherol +(10) 4 Dried leaf(cutting) n.d. n.d. n.d. 37.31±3.25 n.d. n.d. n.d. n.d. +(2.5) 5 Dried leaf(cutting) n.d. n.d. 23.59±1.52 45.15±4.42 9.56±0.55 n.d. n.d. n.d. +(5.0) 6 Dried leaf(cutting) n.d. n.d. 41.74±0.75 n.d. n.d. 21.65±0.47 n.d. n.d. +(2.5) 7 Dried leaf(cutting) n.d. n.d. 56.62±0.36 n.d. 19.46±0.04 n.d. n.d. n.d. +(10) 8 Dried leaf(cutting) n.d. n.d. 51.47±2.88 n.d. n.d. n.d. n.d. n.d. -(10)

aData given as mean±S.D., n=3. Partial modiˆcation of Refs. 6) and 7).bn.d.: Not detected.c+ and - indicate positive and negative, respectively.

= C2H5 以 上 で は 陰 性 で あ っ た ( EAM-2201, JWH-213, JWH-182(Table 2: No. 911)).したがっ て,置換基については,R1=C3H7C7H15, C5H10F, morpholinoethyl 基 及 び ( 1-methylpiperidin-2-yl ) methyl 基は陽性であり,R2及び R3は,それぞれ H及び CH3まで陽性であった(Fig. 1, Table 2,

Group A: No. 18, 12, 13))

.そのほかに,benzoyl-indole 型の AM-694 は陽性であったが(≧50mg/

mL), 同 型 の RCS-4 は 陰 性 で あ っ た ( Table 2, Group B: No. 14, 15).また,naphthoylnaphthalene 型の CB-13 についても陽性を示した(≧250 mg/ mL) (Table 2, Group C: No. 16).

そ の ほ か に 検 討 し た phenylacetylindole 型 (Group D: No. 17, 18),XLR-11(麻薬)等の cy-clopropylindole 型 ( Group E: No. 19, 20 ), naphthoylpyrrole 型 ( Group F: No. 21 ), carbox-yamide derivative型[アミド型:Group J(No. 27 34 )], quinolinyl carboxylate 型 [ エ ス テ ル 型 :

Group K(No. 3537)]はいずれも陰性であった.

また,naphthoylindole 型(Group A)と構造類似 体の naphthoylindazole 型(Group G): JWH-018 in-dazole analog(THJ-018),AM-2201 indazole ana-log(THJ-2201),及び naphthoylbenzimidazole 型 (Group H): AM-2201 benzimidazole analog(FUBI-MINA)は,いずれも陰性であった(No. 2224). Carboxyindole 型 ( Group I ) に つ い て は , naphthyl 基 ( Group A ) の 代 わ り に , piperazinyl

基 や adamantyl 基 が 付 加 し た AB-001 や

MEPIRAPIMは陰性であった(No. 25, 26).また,

cyclohexylphenol 型(Group L: No. 38): cannabicy-clohexanol(麻薬)や大麻の主活性成分である麻薬 D9-THC (Group M: No.

39)も陰性であった(Ta-ble 2). 以 上 の 結 果 か ら , 本 キ ッ ト を 用 い た 一 部 の naphthoylindole 型合成カンナビノイドの検出は可 能であることが示された.麻薬と指定薬物の識別は 難し い もの の ,現 在麻 薬 とし て規 制 され てい る naphthoylindole 型 5 化合物についてはすべて検出 可能であった.しかし,包括指定内の指定薬物の中 でも,置換基の種類(特に R3)により検出不可の

化 合 物 が あ っ た ( Fig. 1 and Table 2 ). ま た , naphthoylindole 型以外では,2 化合物(AM-694, CB-13)が陽性であったが,アミド,エステル,ア ダマンチル,インダゾール,ベンズイミダゾール基 を有する化合物は陰性であった(Table 2). 3. 違 法 ド ラ ッ グ 製 品 試 料 溶 液 を 用 い た 検 討 植物系危険ドラッグ 2 製品(製品 A 及び B,い ずれも危険ドラッグ成分未検出)及び向精神活性植 物「ダミアナ」として入手した植物系 1 製品(製品 C,危険ドラッグ成分未検出)に JWH-018 を添加 後,MeOH 抽出した試料溶液を検討したところ, いずれも陽性であった(≧50 mg/mL,未添加では いずれも陰性)(Table 2, No. 4042).本検出限界 濃度(50 mg/mL)は,製品中の JWH-018 含有量

(7)

0.5% (5 mg/g)に相当した.既報告では,違法ド ラッグ 23 製品中の JWH-018 の含有量は,2.060.0 mg/g(平均 22.0 mg/g)であったことから,6)危険 ドラッグ製品に対しても本キットによる検出が適応 可能であると考えられた.次に,筆者らが既に LC-UV分析により定量を行い,6,7)含有量が既知である 合成カンナビノイド含有 8 製品について検討を行っ た ( Table 3 ). そ の 結 果 , JWH-018, JWH-073, JWH-015又は JWH-200 を含有する 7 製品は,い ずれも陽性であった(Table 3: No. 17)(検出限界 製品濃度 2.510 mg herbal product/mL).一方, JWH-250(化合物自体は陰性)のみ含有製品(Ta-ble 3: No. 8 ) は 陰 性 で あ っ た . し た が っ て , 本 キットは,植物系危険ドラッグ(脱法ハーブ)製品 抽出溶液中の合成カンナビノイドの検出も可能であ ることが示された. Triage DOAなどのイムノアッセイ法を用いた市 販の簡易スクリーニングキットは,偽陽性(偽陰性) を示すことも報告されていることから,その性能を 考慮 した 上 で使 用す る 必要 があ る と考 えら れ る が,8)救急医療などの現場において,“合成カンナビ ノイド(未変化体)”を簡易的に識別する術がない 現状において,本キットは,簡易スクリーニング法 の一選択肢となり得ると考えられる. 以上,本来尿試料用の本薬物スクリーニングキッ トを用いて,一部の naphthoylindole 型合成カンナ ビノイドに限定されるものの,化合物自体(未変化 体)又は危険ドラッグ製品中の化合物の検出が可能 であることを明らかにした.今後,救急医療機関な どにおける薬物簡易スクリーニング法の 1 つとし て,本キットの活用の可能性が示唆された. 謝辞 本研究は,厚生労働省医薬品審査等業務 庁費及び厚生労働科学研究費補助金(医薬品・医療 機器等レギュラトリーサイエンス総合研究事業, H25-医薬-一般-019)の助成により行われたもので, 関係各位に深謝する. 利益相反 開示すべき利益相反はない. REFERENCES

1) Kikura-Hanajiri R., Uchiyama N., Kawamura M., Ogata J., Goda Y., Yakugaku Zasshi, 133, 3140 (2013).

2) Kikura-Hanajiri R., Uchiyama N., Kawamura M., Ogata J., Goda Y., Forensic Toxicol., 31, 4453 (2013).

3) HuŠman J. W., ``The Cannabinoid Recep-tors,'' ed. by Reggio P. H., Humana Press, New York, 2009, pp. 4994.

4) Express Diagnostics Int'l Inc., DrugCheck K2/Spice Test data sheet:〈http://www.drug-check.com/ _ images/ DC236-FUO-G _ K2 _ in-sert.pdf〉, cited 15 October, 2014.

5) Wiley J. L., Compton D. R., Dai D., Lainton J. A., Phillips M., HuŠman J. W., Martin B. R., J. Pharmacol. Exp. Ther., 285, 9951004 (1998).

6) Uchiyama N., Kikura-Hanajiri R., Ogata J., Goda Y., Forensic Sci. Int., 198, 3138 (2010).

7) Uchiyama N., Kawamura M., Kikura-Hanajiri R., Goda Y., Forensic Toxicol., 29, 2537(2011).

8) Sugimura T., Hara K., Kubo S., Nishida T., Yuge R., Ishikura H., JJAAM, 23, 842850 (2012).

Table 1. Analytical Conditions of the K2/Spice Test Kit Condition Compound (conc.) Solvent
Fig. 1. Structures of Tested Compounds
Table 2. Screening of Synthetic and Natural Cannabinoids Using the K2/Spice Test Kit
Table 3. List of Detected Compounds in the Herbal Products a Product No. Form Cannabicy-clohexanol a (mg/g) JWH-018 a(mg/g) JWH-250 a(mg/g) JWH-073 a(mg/g) JWH-015 a(mg/g) JWH-200 a(mg/g) Oleamide a

参照

関連したドキュメント

W ang , Global bifurcation and exact multiplicity of positive solu- tions for a positone problem with cubic nonlinearity and their applications Trans.. H uang , Classification

Let X be a smooth projective variety defined over an algebraically closed field k of positive characteristic.. By our assumption the image of f contains

In particular, we consider a reverse Lee decomposition for the deformation gra- dient and we choose an appropriate state space in which one of the variables, characterizing the

Keywords: continuous time random walk, Brownian motion, collision time, skew Young tableaux, tandem queue.. AMS 2000 Subject Classification: Primary:

Inside this class, we identify a new subclass of Liouvillian integrable systems, under suitable conditions such Liouvillian integrable systems can have at most one limit cycle, and

The main problem upon which most of the geometric topology is based is that of classifying and comparing the various supplementary structures that can be imposed on a

This paper presents an investigation into the mechanics of this specific problem and develops an analytical approach that accounts for the effects of geometrical and material data on

While conducting an experiment regarding fetal move- ments as a result of Pulsed Wave Doppler (PWD) ultrasound, [8] we encountered the severe artifacts in the acquired image2.