EVA28 MG

Fig. 5-3 13C CPMAS NMR spectra; unannealed MG (a), MG annealed at 40 °C for 1 h (b), and MG annealed at 50 °C for 1 h (c).

CH2 (Crystal)

CH2

(Amorphous)

CH3

a

b

c

40 50

as-prepared

Fig. 5-4 DSC thermograms for unannealed MG and annealed MGs; unannealed MG (a), MG annealed at 40 °C for 1 h (b), and MG annealed at 50 °C for 1 h (c).

20 30 40 50 60 70 80 90 100110 Temperature (℃℃℃℃)

Endo up

Heat flow (W/g)

(c) 50

(b) 40

(a) as-prepared

Fig.5-5 Compressive stress–strain curves of Drufosoft® films (thickness = 0.30 cm) before (black) and after (red) repeated compression cycles (5,000 times at 6.0 MPa).

after

before

Fig.5-6 DSC curves of the thermal cycles (100 times), (a) thermal cycles: 25 °C~ 37 °C, (b) thermal cycles: 6 °C~22 °C. Samples: before thermal cycles (black), and after thermal cycles (red).

20 30 40 50 60 70 80 90 100 110

(a) thermal cycles:25 ℃℃℃℃~~~~37 ℃℃℃℃

(b) thermal cycles:6 ℃℃℃℃~~~~22 ℃℃℃℃

20 30 40 50 60 70 80 90 100 110 Temperature (℃℃℃℃)

Heat Flow Endo.

66

66 章章章 総括章 総括総括 総括

本研究では MG の使用による劣化挙動を明らかにするために構造、物性変化に着 目して劣化に影響する因子および劣化機構について検討し以下の結論に至った。

1. 使用前後の MG を比較した結果、化学的変化は無く、分子鎖の切断、架橋 などは生じていなかった。

2. 使用後のMGの咬合部では結晶成分が増加し、分子運動性が束縛された成 分の増加が進行していた。この傾向は 8 個の MG で確認され、統計的にも有 意であることが示された。

3. 温度変化による影響を検討した結果、EVA および製作した MG は熱処理に より、結晶が増加し分子運動性も低下していることが明らかになった。この挙動 は高温で EVA の融点付近での熱処理ほど顕著であるが、口内温度(37℃)に おいても結晶の増加を確認することができた。そのため、使用による結晶の増 加は温度変化による結晶化の進行が原因のひとつであることが明らかになった。

4. 咬合による圧縮による影響を検討した結果、圧縮が繰り返されことで結晶が 増加することが確認できた。このことから、温度に加えて圧縮も結晶化の原因 のひとつであることが明らかになった。

5. 唾液についても影響を検討したが、唾液による顕著な影響は確認できなかっ た。

6. 使用した MG をその後も継続使用できると感じるか否かという使用者本人の 感覚と MG の咬合部の結晶成分が増加との相関は無いことがわかった。つま り、本人の感覚と MG の物性変化には乖離が生じており、MG 使用者本人の 感覚で MG の交換時期(使用期限)を決めることは適切でなく、客観的指標が 必要であることが示唆された。

以上の結論から考えるとMG使用時は温度と圧力を制御することは難しいので、使

用による劣化の進行は避けることはできない。しかし、この劣化の進行は少なくとも低 温で防ぐことができる。つまり、MGの保管を低温で行うことでMGの劣化を防ぐことが できる。この点をMG使用者は理解する必要があり、提供側も使用・保管に関しての 指導を行う必要がある。また、成長期の子供たちに対しては保護者をふくめ、部活動 を指導する学校の教員らにも周知していくことが必要なことである。

一方、MGの劣化は避けることができないため適切な時期に交換する必要がある。

MG使用者本人は機能劣化を感じることができないため、交換のための何らかの指標 を示すことが必要である。継続使用を考えるとMGを破壊せずに測定できる手法が必 要である。本研究においてはMGの一部を切り出すことで結晶化度、緩和時間、融点 などを測定した。しかし、MG全体を用いて咬合部のみの情報を引き出す手法を今後 開発することによりMGを破壊せずに継続可否を判断できると考えられる。その可能 性としてはMG用のMRIが候補の1つとして考えられる。MRIを用いればMG全体 を破壊せずに測定することが可能であり、緩和時間の情報を局所的に測定することも 可能である。このような装置が開発されると、将来、臨床現場で生かされることが期待さ れる。

参考文献 参考文献参考文献 参考文献

1) Reed, R. V. Jr., Origin and early history of the dental mouthpiece, Br. Dent. J., 176, 478–480 (1994).

2) 大橋喬史,河野一郎,安井利一ら, スポーツ歯科臨床マニュアル,日本スポー ツ歯科医学会編,医学情報社,東京, 2007.

3) 安井利一:スポーツとお口の健康,公益社団法人日本歯科衛生士会,東京, 2013.

4) 石上惠一,中島一憲,武田友孝, カスタムメイドタイプ新マウスガードのつくり

方,医歯薬出版株式会社,東京, 2014.

5) 鈴木浩司,上野俊明,武田友孝,竹内正敏, スポーツ選手のための歯科医学

サポート-口の健康,安全と,身体バランス,パワー-,医学情報社,東京, 2016.

6) 学校歯科保健参考資料,「生きる力」をはぐくむ学校での歯・口の健康づくり,

文部科学省, 2013.

7) ADA Council on Access, Prevention and Interprofessional Relations & ADA Council on Scientific Affairs, Using mouthguards to reduce the incidence and severity of sports-related oral injuries, J. Am. Dent. Assoc., 137, 1712–17120 (2006).

8) Sigurdsson, A, Evidence-based review of prevention of dental injuries, Pediatr.

Dent., 35, 184–190 (2013).

9) Ozawa, T., Takeda, T., Ishigami, K., Narimatsu, K., Hasegawa, K., Nakajima, K., Noh, K, Shock absorption ability of mouthguard against forceful, traumatic mandibular closure, Dent. Traumatol., 30, 204–210 (2014).

10) Hasegawa, K., Takeda, T., Nakajima, K., Ozawa, T., Ishigami, K., Narimatsu, K., Noh, K, Does clenching reduce indirect head acceleration during rugby contact?, Dent. Traumatol., 30, 259–64 (2014).

11) Narimatsu, K., Takeda, T., Nakajima, K., Konno, M., Ozawa, T., Ishigami, K, Effect of clenching with a mouthguard on head acceleration during heading of a soccer ball, Gen. Dent., 63, 41–46 (2015).

12) Johnston, T., Messer, L. B, An in vitro study of the efficacy of mouthguard

protection for dentoalveolar injuries in deciduous and mixed dentitions, Endod.

Dent. Traumatol., 12, 277–285 (1996).

13) Takeda, T., Ishigami, K., Hoshina, S., Ogawa, T., Handa, J., Nakajima, K., Shimada, A., Nakajima, T., Regner, C. W, Can mouthguards prevent mandibular bone fractures and concussions? A laboratory study with an artificial skull model, Dent. Traumatol., 21, 134–140 (2005).

14) de Wet, F. A., Heyns, M., Pretorius, J, Shock absorption potential of different mouth guard materials, J. Prosthet. Dent., 82, 301–306 (1999).

15) 石島勉,山口敏樹,月村雅史ら, マウスガードの使用とその外傷防止効果-

北海道アメリカンフットボール選手における調査-,東日本歯学雑誌, 10, 23–32 (1991).

16) 安井利一,前田芳信,田中祐人ら, マウスガードの外傷予防効果に関する大 規模調査について-中間報告-, スポーツ歯誌,17,9–13 (2013).

17) Maeda, Y., Kumamoto, D., Yagi, K., Ikebe, K, Effectiveness and fabrication of mouthguards, Dent. Traumatol., 25, 556–564. (2009).

18) Bourguignon, C., Sigurdsson, A, Preventive strategies for traumatic dental injuries, Dent. Clin. North. Am., 53, 729–749 (2009).

19) Winters, J., DeMont, R, Role of mouthguards in reducing mild traumatic brain injury/concussion incidence in high school football athletes, Gen. Dent., 62, 34–

38 (2014).

20) Warnet, L., Greasley, A, Transient forces generated by projectiles on variable quality mouthguards monitored by instrumented impact testing, Br. J. Sports.

Med., 35, 257–262 (2001).

21) 高野菊雄, これでわかるプラスチック技術,技術評論社, 東京, 2011.

22) Suzuki, H., Harashima, T., Asano, T., Komiyama, O., Kuroki, T., Kusaka, K., Kawara, M, Use of polyolefin as mouthguard material as compared to ethylene vinyl acetate, Int. J. Oral-Med. Sci. 6, 14–18 (2007).

23) Takahashi, M., Koide, K, Optimal heating condition of mouthguard sheet in vacuum-pressure formation: part 2 Olefin-based thermoplastic elastomer, Dent.

Traumatol., 32, 90–94 (2016).

24) Park, J. B., Shaull, K. L., Overton, B., Donly, K. J, Improving mouth guards, J.

Prosthet. Dent., 72, 373–380 (1994).

25) Going, R. E., Loehman, R. E., Chan, M. S, Mouthguard materials: their physical and mechanical properties, J. Am. Dent. Assoc., 89, 132–138 (1974).

26) Bishop, B. M., Davies, E. H., von Fraunhofer, J. A, Materials for mouth protectors, J. Prosthet. Dent., 53, 256–261 (1985).

27) Gould, T. E., Piland, S. G., Shin, J., McNair, O., Hoyle, C. E., Nazarenko, S, Characterization of mouthguard materials: Thermal properties of commercialized products, Dent. Mater., 25, 1593–1602 (2009).

28) Gould, T. E., Piland, S. G., Shin, J., Hoyle, C. E., Nazarenko, S, Characterization of mouthguard materials: Physical and mechanical properties of commercialized products, Dent. Mater., 25, 771–780 (2009).

29) Velayudhan, S., Ramesh, P., Varma, H. K, Effect of vinylacetate content on crystallinity and second-order transitions in ethylene—vinylacetate copolymers, J. Mater. Sci. Mater. Med., 13, 517–522 (2002).

30) Takeda T, The effect of wearing mouthguard and difference of occlusal supportive area on the craniofacial safety, Shikwa Gakuho, 103, 705–713 (2003).

31) Guerard, S., Barou, J.L., Petit, J., Poisson, P, Characterization of mouth-formed mouthguards: thermal performance, Dent. Mater. J., 33, 799–804 (2014).

32) McNair, O. D., Gould, T. E., Piland, S. G., Savin, D. A, Characterization of mouthguard materials: A comparison of a commercial material to a novel thiolene family, J. Appl. Polym. Sci., APP.40402 (2014).

33) Mizuhashi, F., Koide, K., Takahashi, M, Influence of using circle tray on the thickness of the mouthguard, Int. J. Sports Dent., 6, 37–42 (2013).

34) Patrick, D. G., van Noort, R., Found, M. S, cale of protection and the various types of sports mouthguard, Br. J. Sports. Med., 39, 278–281 (2005).

35) Kagiya, S., Sasayama, C., Takamata, T., Kasahara, T., Shoumura, M., Osuga, N., Nakamura, T., Tomida, M., Taniuchi, H., Nagasawa, S, A study of physical and mechanical properties for experimental sports mouthguard materials, Int. J. Sports Dent., 6, 28–36 (2013).

36) Miura, J., Maeda, Y., Machi, H., Matsuda, S, Mouthguards difference in longitudinal dimensional stability between single- and double-laminated fabrication techniques, Dent. Traumatol., 23, 9–13 (2007).

37) Patrick, D. G., van Noort, R., Found, M. S, The influence of heat treatment on the impact performance of sports mouthguard materials, Compos. Part A Appl. Sci.

Manuf., 37A, 1423–1427 (2006).

38) Takeda, T., Ishigami, K., Kawamura, S., Nakajima K., Shimada, A. Regner C. W, The influence of impact object characteristics on impact force and force absorption by mouthguard material, Dent. Traumatol., 20, 12–20 (2004).

39) Meng, F. H, Schricker, S. R., Brantley, W. A., Mendel, D. A., Rashid, R. G., Fields, H. W. Jr, Vig Katherine W. L, Alapati S. B, Differential scanning calorimetry (DSC) and temperature-modulated DSC study of three mouthguard materials, Dent. Mater., 23, 1492–1499 (2007).

40) Tran, D., Cooke, M. S., Newsome, P. R, Laboratory evaluation of mouthguard material, Dent. Traumatol., 17, 260–265 (2001).

41) 蟹江隆人,富田浩一,上川善昭ら, 歯科用軟質材料の臨床的使用期限を設 定するための基礎的研究,日歯医学会誌,31, 79–83 , 2012.

42) 奥居徳昌,河合徹, エチレン-酢酸ビニルランダム共重合体における 2 成分結 晶化,高分子論文集,31, 190–196 , 1974.

43) Arsac, A., Carrot, C., Guillet, J, Rheological characterization of ethylene vinyl acetate copolymers, J. Appl. Polym. Sci., 74, 2625–2630 (1999).

44) Shi, X. M., Zhang, J., Jin, J., Chen, S. J, Non-isothermal crystallization and melting of ethylene-vinyl acetate copolymers with different vinyl acetate contents, Express Polym. Lett., 2, 623–629 (2008).

45) スポーツ基本法(平成23年法律第78号)(条文),文部科学省 , 2011.

46) Zhang, Q., Lin, W., Yang, G., Chen, Q, Studies on the phase structure of ethylene-vinyl acetate copolymers by solid-state 1H- and 13C-NMR, J. Polym. Sci. B Polym.

Phys., 40, 2199–2207 (2002).

47) Wang, L., Fang, P., Ye, C., Feng, J, Solid-state NMR characterizations on phase structures and molecular dynamics of poly(ethylene-co-vinyl acetate), J. Polym.

Sci. B Polym. Phys., 44, 2864–2879 (2006).

48) 安藤勲, 高分子の固体NMR,講談社,東京 (1994).

49) プラスチック成型品の高次構造解析入門,(社)プラスチック成形加工学会編,

日刊工業新聞社,東京, 2006.

50) Kakiage, M., Uehara, H., Yamanobe, T, Novel in situ NMR measurement system for evaluating molecular mobility during drawing from highly entangled polyethylene melts, Macromol. Rapid. Commun., 29, 1571–1576 (2008).

51) Uehara, H., Yamanobe, T., Komoto, T, Relationship between solid-state molecular motion and morphology for ultrahigh molecular weight polyethylene crystallized under different conditions, Macromolecules, 33, 4861–4870 (2000).

52) Suzuki, T., Takahashi, K., Uehara, H., Yamanobe, T, Application and analysis of a DSC Raman spectroscopy for indium and poly (lactic acid), J. Therm. Anal.

Calorim., 113, 1543–1549 (2013).

53) 栗原伸一, 入門統計学-検定から多変量解析・実験計画法まで-,株式会社 オーム社,東京 , 2011.

54) 水本登志雄,新家光雄ら, 歯科用銀パラジウム銅金合金の人工唾液中におけ

る疲労特性,歯科材料・器械,20, 334–343 , 2001.

55) 小坂勇次郎, エチレン酢酸ビニル共重合体の構造と物性 (II),高分子,18,

386–391 , 1969.

56) Bistac, S. Kunemann, P. Schultz, J, Crystalline modifications of ethylene-vinyl acetate copolymers induced by a tensile drawing: effect of the molecular weight, Polymer, 39, 4875–4881 (1998).

57) Jin, J., Chen, S., Zhang, J, UV aging behaviour of ethylene-vinyl acetate copolymers (EVA) with different vinyl acetate contents, Polym. Degrad. Stab., 95, 725–732 (2010).

58) Brogly, M., Nardin, M., Schultz, J, Effect of vinylacetate content on crystallinity and second-order transitions in ethylene—vinylacetate copolymers, J. Appl.

Polym. Sci., 64, 1903–1912 (1997).

59) Nomoto, M., Komoto, T., Yamanobe, T, Structure and curing mechanism of high-orhto and random novolac resins as studied by NMR, J. Mol. Struct., 976, 419–

426 (2010).

60) Yamanobe, T., Uehara, H, “Chapter 8–NMR analysis of morphology and structure of polymers”, in Polymer morphology: Principles, characterization, and processing, Guo, Q. edited, John Wiley & Sons: 131–150 (2016).

関連したドキュメント