The FA goods manufactured by Mitsubishi Electric Engineering Co., Ltd. include various types of equivalent terminal block converter modules, e.g. screw terminal block type, spring clamp terminal block type and e-CON terminal block type. An appropriate one can be selected from the wide product line.

For details on the FA goods manufactured by Mitsubishi Electric Engineering Co., Ltd., please contact your local Mitsubishi sales office or representative.

•‥ Using‥the‥relay‥terminal‥modules,‥a‥large‥type‥A‥(Large‥Type)‥Series‥32-point‥contact‥output‥

module‥can‥be‥replaced‥while‥maintaining‥8‥points/common.

•‥ A‥wide‥variety‥of‥compatible‥wire‥sizes‥are‥available‥using‥the‥relay‥terminal‥module.

A‥(Large‥Type)‥Series‥32-point‥contact‥output‥module‥AY13:‥Max.‥2‥mm2 Relay‥terminal‥module:‥Max.‥1.25‥mm2

Q‥Series‥16-point‥contact‥output‥module‥QY10:‥Max.‥0.75‥mm2

•‥ Replacement‥is‥possible‥without‥the‥need‥of‥additional‥modules‥because‥a‥module‥mounted‥on‥

the‥base‥unit‥becomes‥compatible‥with‥32-point‥connector‥type‥modules‥through‥the‥use‥of‥the‥

"connector/terminal‥block‥converter‥module".‥

(a)‥System‥configuration‥example

Current‥configuration After‥replacement

Replace

For positive common input modules and sink output modules (standard type) For positive common input modules and sink output modules (2-wire type) For positive common input modules (3-wire type)

For negative common input modules (standard type) For negative common input modules (2-wire type) For negative common input modules (3-wire type) For source output modules (standard type) For source output modules (2-wire type)

0.4 kg 0.5 kg 0.6 kg 0.4 kg 0.5 kg 0.6 kg 0.4 kg 0.5 kg

2.1 Replace A/QnA (Large Type) Series with Q Series

The following is an example of replacing contact output modules (AY13) with transistor output modules (QY41P) and externally converting transistor outputs into contact outputs.

● Instructions

Replace AY13 with QY41P and connect the relay terminal modules to convert to contact outputs.

With this method, the system can be upgraded without increasing the number of modules on the base unit.

Also, 8 points/common, the same specification as that of the AY13, can be maintained.

Q61P Q01UCPU QX41 QX41 QX41 QX41 QX42

Q61P QY41P QY41P QY41P QY41P QY41P

A61P A2NCPU AX41 AX41 AX41 AX41 AX42

A61P AY13 AY13 AY13 AY13 AY13

X00... X20... X40... X60... X80...

YC0... YE0... Y100... Y120... Y140...

A35B

A65B

QY41P

16-point relay terminal module x 2 (A6TE2-16SRN) Dedicated cable

(ACTE)

Reray terminal module Reray terminal module 8 points/common

(the same specification as that of AY13)

•‥ Using‥the‥relay‥terminal‥modules,‥a‥large‥type‥A‥(Large‥Type)‥Series‥32-point‥contact‥output‥

module‥can‥be‥replaced‥while‥maintaining‥8‥points/common.

•‥ A‥wide‥variety‥of‥compatible‥wire‥sizes‥are‥available‥using‥the‥relay‥terminal‥module.

A‥(Large‥Type)‥Series‥32-point‥contact‥output‥module‥AY13:‥Max.‥2‥mm2 Relay‥terminal‥module:‥Max.‥1.25‥mm2

Q‥Series‥16-point‥contact‥output‥module‥QY10:‥Max.‥0.75‥mm2

•‥ Replacement‥is‥possible‥without‥the‥need‥of‥additional‥modules‥because‥a‥module‥mounted‥on‥

the‥base‥unit‥becomes‥compatible‥with‥32-point‥connector‥type‥modules‥through‥the‥use‥of‥the‥

"connector/terminal‥block‥converter‥module".‥

Solution and Benefit

(a)‥System‥configuration‥example

Current‥configuration After‥replacement

Replace

(2) Replace 32-point contact output type module using "relay terminal module"

Product name

Power supply module A61P 2 Q61P

Existing model Replacement model 2

CPU module A2NCPU 1 Q01UCPU 1

Main base unit A35B 1 Q38B* 1

Extension base unit A65B 1 Q68B 1

Extension cable AC06B 1 QC06B 1

Input module AX41 4 QX41-S2 4

Connector/terminal block converter module N/A - A6TBXY36 4

Cable (for connector/terminal block converter module) N/A - AC฀TB 4

Input module AX42 1 QX42 1

Output module AY13 5 QY41P 5

Relay terminal module N/A - A6TE2-16SRN 10

Cable (for relay terminal module) N/A - AC06TE 5

AC06TE

Model Length (L)

AC10TE AC30TE AC50TE AC100TE

L

B A 350 mm

350 mm

B-side: Second half

16 pts. (Y10 to Y1F) Unit: mm

A-side: First half

16 pts. (Y0 to YF)

* The Q312 can be used if the control panel is wide enough. With the Q312B, the I/O modules can be mounted on one base unit, eliminating the need for the Q68B extension base unit, QC06B extension cable, and one Q61P power supply module.

Note: The relay terminal module can function as a relay terminal block while performing contact outputs.

52.6

(b) Module selection example

(c) Relay terminal module (A6TE2-16SRN)

(e) Cables

The connection cables compatible with A6TE2-16SRN are shown below.

(d) External dimensions

Ф

Ф

(cos Ф =0.7): 100,000 times or more (cos Ф =0.35): 100,000 times or more (cos Ф =0.7): 200,000 times or more

(cos Ф =0.35): 200,000 times or more

0.6 m 1.0 m 3.0 m 5.0 m 10.0 m

2.1 Replace A/QnA (Large Type) Series with Q Series

AC฀TB

Item AY13

Number of output points Use two A6TE2-16SRN modules

when using more than 16 points.

16 points

○: Compatible, △: Partially changed A6TE2-16SRN

Compati-bility Remarks

32 points

Isolation method The isolation method differs, but the

isolation performance is equivalent.

The electrical life of the A6TE2-16SRN is half of the AY13's life. However, the relay for the A6TE2-16SRN can be replaced.

Relay

Photocoupler

External power supply

Wiring modification is required.

The supplied current value will be larger.

24 V DC ±10%

Ripple voltage: 4 Vp-p or less 24 V DC ±10%

Ripple voltage: 4 Vp-p or less

350 mA

(TYP. 24 V DC, all points ON) 290 mA

(TYP. 24 V DC, all points ON) Electrical

Rated switching voltage/current load: 100,000 times or more Rated switching voltage/current

load: 200,000 times or more Maximum switching

voltage

264 V AC

125 V DC

264 V AC 125 V DC

External connections 38-point screw terminal block

(M3 screw) (M3 × 6 screws) 38-point terminal block

connector (M3 × 6 screws)

Applicable wire size 0.75 to 2 mm2 0.75 to 1.25 mm2

Applicable crimping terminal

R1.25-3, R1.25-MS3, R1.25-B3A, R1.25-C3A, RAV1.25-3, RAV1.25-MS3,

RAV1.25-B3A R1.25-3, R2-3,

RAV1.25-3, RAV2-3 Rated switching

voltage/current

24 V DC/2 A (resistive load)/point, 240 V AC/2 A (cos Ф =1)/point,

8 A/common 24 V DC/2 A (resistive load)/point,

240 V AC/2 A (cos Ф =1)/point, 5 A/common

Common terminal arrangement

8 points/common (common terminals:

TB19, TB21)

8 points/common

(common terminals:

TB9, TB18, TB27, TB36)

Minimum switching load 5 V DC 1 mA 5 V DC 1 mA

Operation indicator ON indication (LED) ON indication (LED) Maximum switching

frequency 3600 times/hour 3600 times/hour

Response time

10 ms or less

10 ms or less ON to OFF

OFF to ON 12 ms or less 12 ms or less

200 V AC 1.5 A, 240 V AC 1 A (cos Ф =0.7): 100,000 times or more

200 V AC 0.7 A, 240 V AC 0.5 A (cos Ф =0.35): 100,000 times or more

24 V DC 1 A, 100 V DC 0.1 A (L/R=7 ms): 100,000 times or more

200 V AC 1.5 A, 240 V AC 1 A

(cos Ф =0.7): 200,000 times or more 200 V AC 0.7 A, 240 V AC 0.5 A (cos Ф =0.35): 200,000 times or more

24 V DC 1 A, 100 V DC 0.1 A (L/R=7 ms): 200,000 times or more Mechanical

Voltage Current

20 million times or more 20 million times or more

Life

(f) Specifications comparison between AY13 and A6TE2-16SRN

•‥ Use‥the‥Q‥Series‥large‥type‥input‥module‥QX21L‥to‥replace‥the‥modules‥without‥changing‥the‥

wiring.

Note‥that‥if‥the‥Q‥Series‥large‥type‥base‥unit‥cannot‥be‥used‥because‥of‥space‥limitations‥in‥the‥

panel‥or‥because‥of‥the‥module‥configuration,‥etc.,‥replacements‥can‥be‥completed‥easily‥by‥

using‥the‥FA‥goods.

•‥ A‥dedicated‥cable‥is‥available‥to‥connect‥the‥programmable‥controller‥with‥the‥FA‥goods,‥so‥

there's‥no‥need‥to‥prepare‥cables‥when‥making‥a‥replacement.

• The FA goods input module has a function to convert 200 V AC input signal into 24 V DC, so select a 24 V DC input connector type module for the programmable controller side input module.

• The following products are available for the FA goods.

Triac large capacity (1 A/point) output module Transistor large capacity (2 A/point) output module Common multi-point I/O module

The FA goods can be used when replacement using the Q Series large type I/O module conversion adapter is difficult.

For details on the FA goods manufactured by Mitsubishi Electric Engineering Co., Ltd., please contact your local Mitsubishi sales office or representative.

• To replace using existing external wiring terminal block, use the Q Series large type input module QX21L.

Refer to "2.1.2 Upgrade to Q Series using Q Series large type base unit and I/O modules" for details.

Replace

(3) Replace A/QnA (Large Type) Series 200 V AC input module AX21

[Use FA goods (manufactured by Mitsubishi Electric Engineering Co., Ltd.)]

The following is an example of replacing the A (Large Type) I/O module with the Q Series using FA goods.

‥Instruction

(1) Using the FA goods, convert the 200 V AC input into 24 V DC, and lead it in with QX41, etc.

(2) The external wiring will change, but program does not need to be changed since the I/O address is the same. (3) The following FA goods are used.

‥System‥configuration‥example

‥Connection‥cable

‥Module‥selection‥example Power supply moduleProduct name CPU module

Input module Main base unit

Existing model Replacement model 1

1