The debate over Category 8

Cabling

Cat8ケーブルをめぐる議論

Ravi Doddavaram Psiber Data [email protected] ラビ・ドッドラバラム氏 サイバーデータ社 Japan

(2)

Given: We are moving towards higher link rates

前提:さらなる高密度リンクへ

Still Not Interesting

40 Gbps (LOM) or LAG

10 Gbps(LOM) Romely for instance

Virtual NICs push bandwidth requirements on Servers/Access

高速イーサネットの普及

仮想化ニックスはサーバー/アクセス帯域幅 需要を押していきます。

(3)

40G Base-T working around the pitfalls

40GBast-Tの問題点

 Power Consumption 消費電力

 With 28nm Technology, power consumption ratio is about 2:1 as 40GBASE-SR4 alternative

28nm技術で電力消費率は40GBase-SR4代替と比較して約2倍

 IEEE has taken this into consideration hence higher bandwidth of cabling IEEEでは電力消費を考慮し、ケーブル帯域幅をより高く考えています

 Initial per port power is 4~5 Watts, (early 10GBASE-T about 25 Watts)

1ポートの初期電力は4~5W(初期10GBaseTは約25W)

40G Base-T Class II, 1.6 GHz 40G Base-T Class I, 1.6 GHz

(4)

 Reach objective

対象の距離

 Two layer Datacenter architecture, Fabric Architectures lead to MoR or EoR architectures 2つのレイヤのデータセンタアーキテクチャ、ファブリックアーキテク チャはMiddle of RowあるいはEnd of Row構造に進んでいく

 40GBase-T for supporting 30m reach (EoR, MoR) configuration with a 30m objective 30m距離をサポートする40GBase-T

10GBASE-T deployment

40GBASE-T deployment

40G Base-T working around the pitfalls

40GBast-Tの問題点

(5)

 Gb/ポートあたりのコスト・使用効率

 DAC supports up to 7m but utilization efficiency is poor Direct Attached Cableは7mまでサポートできるが、使用効率はよくない

 Active links are expensive

アクティブリンクは高額

 LOM of 10G will drive cost per Gb down

10G LAN On MotherboardはGbあたりのコストダウンを生み出す

 EoR vs ToR debate

End of Row 対Top of Rackの論争

40G Base-T working around the pitfalls

40GBast-Tの問題点

(6)

40G Base-T Deployment scenarios

40G Base-T 展開シナリオ

(7)

40G Base-T Deployment scenarios

40G Base-T 展開シナリオ

(8)

Source: Aquantia

Then why Base-T even today? ToR vs EoR

(9)

Source: Aquantia

Then why Base-T even today? ToR vs EoR

(10)

CAT 8 Cabling: Frequently Asked Questions

CAT8:FAQ

 Why still copper networks?

いまだにメタルケーブルのネットワークの意味は?

 Rapid adoption of 10GBASE-T 10GBase-Tの迅速な移行

 Cheaper than Fiber Deployment for horizontal Cabling

水平ケーブリングのファイバ導入よりも安価

 When is it likely to happen?

いつ頃からCAT8

 Standardization work in progress; PHY definition by mid 2016

規格化の作業は進行中;2016年の中頃には物理層が定義

 Early adopters by 2017, depends on when NEM vendors launch the technology (Acquantia, BroadCom etc. part of the development) 早ければ2017年導入。ネットワーク 装置メーカー(Acquantia,BroadCom等)がこの技術を始めるタイミングによる

 How different is Structured Cabling Value Chain?

敷設されたケーブリング網と何が違うのか

 SI’s with UTP/FTP installation background extremely relevant, but need an upgrade in skill set

SIによるUTP/FTP導入は当面重要で、技能の向上も必要

 Investment in new set of tools necessary, tools capable of supporting higher frequencies, connectivity etc.

(11)

Tug of War: 2GHz or 1600 MHz which is better?

綱引き:2GHzか1600MHzか、どちらがいい?

 Look at the holistic picture:

全体像をみる

 2GHz at what Crosstalk or Insertion loss limits?

2GHzでどんなクロストークあるいは挿入損失の規格があるのか

 Channel Capacity (Shannon Capacity, “Margin”):

チャネルの容量(シャロン容量、“マージン”)

 Key for IEEE to come up with the Physical layer Specification

IEEEのキーポイントは物理層の仕様を示す

 Both TIA and ISO limits either at 2000 MHz or 1600 MHz will comply to IEEE requirement

(12)

Tug of War: 2GHz or 1600 MHz which is better?

綱引き:2GHzか1600MHzか、どちらがいい?

 Look at the holistic picture:

全体像をみる

 2GHz at what Crosstalk or Insertion loss limits?

2GHzでどんなクロストークあるいは挿入損失の規格があるのか

 Channel Capacity (Shannon Capacity, “Margin”):

チャネル容量(シャロン容量、“マージン”)

 Key for IEEE to come up with the Physical layer Specification

IEEEのキーポイントは物理層の仕様を示す

 Both TIA and ISO limits either at 2000 MHz or 1600 MHz will comply to IEEE requirement

2000MHzでも1600MHzでも、TIAとISO規格両方とも、IEEEの要求に適合します。

 Connectivity 接続性

 Three different types will be standardized 3種類の違うタイプが規格化

RJ45 Enhanced/GG45 Enhanced/TERA Enhanced

*Certification Tools available today support all three options

(13)

Current status of Standards

規格の現状

• IEEE 802.3 NGBASE-T Study Group has become the IEEE P802.3bq 40GBASE-T Task Force. Expected by Feb’2016. Work has begun in defining the PHY

specification IEEE802.3NGBase-Tの研究グループはIEEE P802.3bq 40GBase-Tタスクフォースに変更。 2016年2月に予想。物理層仕様の定義作業は既に開始

• IEEE is influencing alignment between TIA TR-42.7 and ISO/IEC JTC 1/SC 25/WG 3 on specifications for cabling systems being developed for use with 40GBASE-T 40GBase-Tを実現させるため、IEEEはTIA TR-42.7とISO/IECJTC1/SC25/WG3と共同作業を実施 している。

• Current draft of TIA 568 C.2 for CAT 8 defined for most parameters for

Channel performance CAT8のTIA568 C.2の現時点のドラフトでは、チャネルのほとんどのパラメータは 定義されました。

• Liaison from IEC TC46/WG9 to IEC SC25/WG3 for 2GHz Field Testing draft is agreed upon 2GHzフィールドテストのドラフトについては、IECのTC46/WG9からSC25/WG3に主幹ワーキ ンググループが移っている。

• Field Tester standard, Level 2G task group has been established

(14)

TIA Category 8

TIA カテゴリー8

 1 MHz to 2000 MHz

 Support for 40GBASE-T (IEEE P802.3bq)

40GBase-TIEEE P802.3bq)をサポート

 Insertion Loss (IL) is critical parameter 挿入損失が重要パラメータ

 30m Channel Length, 26m Permanent Link Length 30mチャネル長、26mパラメタリンク長

 Approx. 55% of Channels <30m :チャネルの約55%は30m未満

 Improved Cat6A components 改良されたCat6A コンポーネント

 RJ45 Plug / Jack (Cat 8.1)  F/UTP or S/FTP Cable

 2 connector configuration 2か所の接続構成

 Extension of Cat6A Limits to 2000MHz. Cat6A規格の2000MHzへの延長

 Additional higher performance grade based on enhanced CAT7A components (Cat 8.2) エンハンスドCAT7Aコンポーネントに基づく高いパフォーマンスレベルの追加(Cat8.2)

 TIA 568-C.2-1 Draft 0.9 (expected to be published in 1 year)

(15)

TIA Cabling for IEEE 802.3 40GBASE-T

(draft)

TIA ケーブリング IEEE802.3 40GベースT(ドラフト)

Cat8.1

2000 MHz

New &

Improved Cat6A

Components

30m 2 Connectors

Cat8.2

2000 MHz

New &

Improved Cat7A

Components

30m 2 Connectors 新タイプ・改良Cat6A 新タイプ・改良Cat7A

(16)

0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 55.00 60.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000

TIA Cat 8 CH IL TIA Cat 6A CH IL TIA Cat 6 CH IL TIA Cat5e CH IL

TIA Insertion Loss Limit

TIA 挿入損失 規格値

Cat 8*

Cat 6A Cat 6

Cat 5e

*CAT8 limits are based on early draft

(17)

ISO Cabling for IEEE 802.3 40GBASE-T

(draft)

ISO

ケーブリング

IEEE802.3 40G

ベース

T

(ドラフト)

ClassF

A

1000 MHz

Standardized ClassFA Components 25m 2 Connectors

ClassFA 40G

1600 GHz

Standardized Cat7A Components 30m 2 Connectors

Class I

2000 MHz

New & Improved Cat6A Components 30m 2 Connectors

Class II

2000 MHz

New & Improved Cat7A Components 50m 2 Connectors 規格化 規格化 新タイプ・改良Cat6A 新タイプ・改良Cat7A

(18)

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 0 200 400 600 800 1000 1200 1400 1600 1800 2000

ISO Class I CH IL ISO Class II CH IL ISO 40G CH IL ISO FA CH IL

ISO F CH IL ISO EA CH IL ISO E CH IL ISO D CH IL *limits are based on early draft

ISO Class I / Class II : Insertion Loss Limit

ISO クラスⅠ/クラスⅡ:挿入損失の規格値

Class II* Class I* FA 40G* FA EA F D E

(19)

How to qualify or Test CAT 8 Transmission performance

CAT8伝送能力の認証と試験方法

 Transmission parameters are exactly same as those of CAT6A, Class EA requirements

伝送のパラメータはCAT6A,CLASS EA要求とほぼ同じ  NEXT, RL, Insertion Loss, PSANEXT etc.

 Frequency of measurement should be at least 1600 MHz 周波数測定は最低1600MHzであるべき

 Connecting Hardware (modules) yet to be standardized

ハードウェア(モジュール)の接続はまだ規格化されていない

 ISO yet to define the component specification, but TIA is close to defining it

ISOはコンポーネントの規格を定義しておらず、TIAは定義間近

 Field Test standard is under way in both ISO/IEC as well as TIA

フィールドテスト規格はTIA同様、ISO/IEC両方で協議中

 Disclaimer: Demonstration of CAT 8 cabling measurements to draft standards doesn’t mean 40GBase-T performance demonstration!

(20)

Refresher TIA Standards

TIA規格

Common Standards Premise Standards Component Standards

ANSI/TIA 568 C.0

(Generic)

ANSI/TIA 569 C

(Pathway and spaces)

ANSI/TIA 606 B (Administration) ANSI/TIA 568 C.1 (Commercial) ANSI/TIA 570 C (Residential) ANSI/TIA 942-A (Datacenters) ANSI/TIA 568 C.2 (Balanced Twisted Pair )

ANSI/TIA 568 C.3 (Optical Fiber)

ANSI/TIA 568 C.4 (Coaxial)

ANSI/TIA 1152-A

(Testing of twisted pair )

共通の規格 前提の規格 構成品の規格

(21)

Refresher TIA Standards

TIA規格

Defines testing procedure, standards for testers such as Level IV, 2G etc.

Common Standards Premise Standards Component Standards

ANSI/TIA 568 C.0

(Generic)

ANSI/TIA 569 C

(Pathway and spaces)

ANSI/TIA 606 B (Administration) ANSI/TIA 568 C.1 (Commercial) ANSI/TIA 570 C (Residential) ANSI/TIA 942-A (Datacenters) ANSI/TIA 568 C.2 (Balanced Twisted Pair )

ANSI/TIA 568 C.3 (Optical Fiber)

ANSI/TIA 568 C.4 (Coaxial)

ANSI/TIA 1152-A

(Testing of twisted pair )

共通の規格 前提の規格 構成品の規格

ツイストペアの試験 テストの手順、レベルⅣや2Gのようなテスタの規格を定義

(22)

Refresher ISO Standards

ISO規格

ISO/IEC 24764 (Datacenters)

IEC 61935-1

(Specifications for testing balanced cabling)

IEC 14763-3

(Specifications for testing balanced cabling)

ISO/IEC 11801

(Generic Cabling, Copper and Fiber)

ISO/IEC 18010 (Pathways and spaces)

ISO/IEC 14763-2 (Administration)

データセンター

ケーブル試験の仕様 一般的ケーブル・メタル配線・ファイバ 管理

(23)

Refresher ISO Standards

ISO規格

ISO/IEC 24764 (Datacenters)

IEC 61935-1

(Specifications for testing balanced cabling)

IEC 14763-3

(Specifications for testing balanced cabling)

ISO/IEC 11801

(Generic Cabling, Copper and Fiber)

ISO/IEC 18010 (Pathways and spaces)

ISO/IEC 14763-2 (Administration)

Defines testing procedure, standards for testers such as Level IV, 2G etc.

データセンター

ケーブル試験の仕様 一般的ケーブル・メタル配線・ファイバ 管理

ケーブル試験の仕様 配線経路・スペース

(24)

Testing without a standard? What does it mean.

規格なしの試験?どのような意味

試験対象のケーブル 校正用冶具 フィールドテスタ フィールドテスタ NEXT・リターンロス測定には終端。 挿入損失とFEXTを測定するためネット ワークアナライザに接続

(25)

Test Adapters & Calibration Artifacts

テストアダプタと校正工具

(26)

Network Analyzer

ネットワークアナライザ

Network Analyzer ネットワークアナライザ Field Tester フィールドテスタ

(27)

17.08.2007 Seite 27

Return Loss

(28)

Near End Crosstalk

(29)

Insertion Loss

(30)

Known Issues with high frequency cable designs

高周波ケーブル設計でのよくある問題

Insertion Loss suck outs 挿入損失で急激に悪化します • Typically seen in screened systems above 1300 MHz.

1300MHz以上のスクリーンシステムで発生する傾向があります

• Usually the cause is the improper shield termination to connectors, or shield lay-lengths.通常、原因はコネクタでのシールドの不確かな成端あるいはシールド層の長さにあります。

(31)

Alien Crosstalk Measurements

エイリアンクロストーク測定

被測定対象 メインユニット 測定対象 メインユニット 被測定対象 リモートユニット 被測定対象 リモートユニット 測定対象 被測定対象 RJ45パッチコード パッチパネル

(32)

Alien Crosstalk Measurements

エイリアンクロストーク測定

-120 -110 -100 -90 -80 -70 -60 -50 0 200 400 600 800 1000 1200 1400 1600 1800 2000

F/UTP Cable ANEXT

"36-12 -NA" Pair_36-12-WX -120 -100 -80 -60 -40 0 200 400 600 800 1000 1200 1400 1600 1800 2000

UTP Cable ANEXT

"12-12-NA" Pair_12-12-WX

(33)

Alien Crosstalk: Is it still the white Elephant?

エーリアンクロストーク:依然として“やっかいもの”?

 Still a very key measurement for 10G Base-T installations. Several installation issues go un-noticed

いまだ10GBase-T工事で重要な測定です。ある工事では、この問題は無視されています。

 Field testing doesn’t have to be complex anymore

フィールドテストはこれ以上複雑化しなくてもよいはず

 One of the few measurements that directly correlates to BER (application bandwidth). TCL, ELCTCL are secondary effects which show up as Alien Crosstalk or Near End Crosstalk

2,3の測定の一つで直接ビットエラーレートと関係しています。TCL、ELCTCLはエイリアンク

ロストークあるいは近端クロストークの時にみられる二次的な効果です。

 Perhaps not so important in the shielded world (Realm of CAT 8) but work still in progress

(34)

Additional Measurements?

追加測定

ELTCL, LCTCL, Coupling Attenuation カップリングアッティネータ

• Measure of balance of the twist of cabling and noise rejection of the cable

ケーブルのツイストバランス測定と、ノイズ排除

• Not very meaningful in the field because it is a inherent property of the cable or connector,

not much can be done in the field to rectify it

ケーブルやコネクタの固有プロパティで、調整目的でフィールドで実施される程ではなく、現場では意味がない

• Will be interesting to see how repeatable the measurements are with different common

mode impedances of different cables in the field

違うケーブルの違うコモンモードインピーダンスを使って、どの程度の再現性で測定が実施されるかは興味深いです

• A fault in ELTCL, Coupling Attenuation will always result in a NEXT, Alien Crosstalk failure.

Instead of tightening limit for a new measurement might as well look at the NEXT performance

ELTCLでのfailure、カップリングアッティネータは、常にNEXT、エイリアンクロストークのFAILに起因します。 新しい測定で規格を厳しくしたら、NEXTの結果に注視すればよいでしょう

• ISO/IEC liaison letter to TC46 requests the committee the need to evaluate suitability of

this measurement in the field along with Coupling attenuation measurement

TC46へのリエゾンレターで、ISO/IECはカップリングアッティネータ測定と共にフィールドでのこの測定の適合性評価の 必要性を委員会に要望しています。

(35)

End to End testing: Concept

エンドツーエンドテスト:コンセプト

 Comparison with network analyzer is a problem due to soft de-embedding in channel testing

チャネル試験で埋め込んだものを取り除いてしまうので、ネットワークアナライザによる比較には問題があります。

 Issue typically seen at higher frequencies

高周波でよくみられる問題

 Proposal to include “Patch cord” type test configuration for CAT 8 cables

CAT8ケーブルではパッチコードタイプテスト構成を含ませるような協議が実施されています。

 Widely supported but no additional effort required as Field testers already support “Patch

Cord configuration” 上述は広く認知された方法で、新たな開発が必要とすることはないでしょう。 また、既存フィールドテスタではパッチコード試験は可能です。 Existing configuration 既存の構成 Channel under Test

Field Tester Field Tester

(36)

The End

おわりに

 Psiber Data is an active member on both TIA & ISO Cabling committees.

PsiberData社はTIA及びISOのケーブル委員会に積極的に参加しています。

 Level V Field Tester Standard expected soon

 (All of us field test manufacturers claim compliance, but the standard is still in draft state)

測定確度レベルVの確立は、もうまもなくです。

(フィールドテストメーカー全社は承諾の姿勢。一方、規格自体はいまだ検討段階)

 Discussion on Level 2G has started (Please note the difference in the name no more level IV, V)

レベル2Gの協議が始まっています (注意:レベル“Ⅳ”や”V“のような名前とは違います)

Thank you 御清聴ありがとうございました

参照

関連したドキュメント

The connection weights of the trained multilayer neural network are investigated in order to analyze feature extracted by the neural network in the learning process. Magnitude of

pair of ables whih provide power supply and om-.

In the present paper, the methods of independent component analysis ICA and principal component analysis PCA are integrated into BP neural network for forecasting financial time

We present the new multiresolution network flow minimum cut algorithm, which is es- pecially efficient in identification of the maximum a posteriori (MAP) estimates of corrupted

Rybko, A.N., Stationary distributions of time homogeneous Markov processes modeling message switching communication networks, Problems of Information Transmission 17.

We present the new multiresolution network flow minimum cut algorithm, which is es- pecially efficient in identification of the maximum a posteriori (MAP) estimates of corrupted

The proposed model in this study builds upon recent developments of integrated supply chain design models that simultaneously consider location, inventory, and shipment decisions in

The excess travel cost dynamics serves as a more general framework than the rational behavior adjustment process for modeling the travelers’ dynamic route choice behavior in