• 検索結果がありません。

Test Procedure for the NCV7535EVB

N/A
N/A
Protected

Academic year: 2022

シェア "Test Procedure for the NCV7535EVB"

Copied!
3
0
0

読み込み中.... (全文を見る)

全文

(1)

Test Procedure for the NCV7535EVB

15/Oct/2018

Figure 1: Test Setup Configuration Oscilloscope

1 2 3 4 Dig

+ -

Power Supply

A V

4R7 25W

V V

(2)

Required Equipment

 Oscilloscope

 Bench Power Supply, current capability min. 3 A, Ampermeter

 Voltmeter (alternatively free oscilloscope channel)

 PC Software for NCV7535 EVB Control

 Micro USB Cable

 NCV7535 Evaluation Board (NCV7535_EVB_V3)

Test procedure Step 1 (Standalone mode):

1. Turn Pot1 left

2. Move SW1-4 to the right positions (OFF) 3. Connect supply

4. Check IBAT

5. Check OUT1/2 state 6. Check VCHP

7. Check Vsen voltage 8. Turn Pot1 right 1. Check OUT1/2 state

2. Move SW1 to the left position (ON) 3. Check OUT1/2 state

Table 1: Desired Results

IBAT = IBAT_SA

OUT1/2 = PWM duty-cycle per Pot1 position VCHP = VCHP

Vsen = Vsen_off (when duty-cycle 0%) Vsen = Vsen_on (when duty-cycle 100%) LED1 off, LED2 on, LED3 off, LED4 off

(3)

Test procedure Step 2 (PC Mode, HS1 + LS2 on):

1. Connect USB

2. Start NCV7535 Control Software

3. After connected virtual COM port appears, click “Connect” button 4. Click “Run Forward” button in “Basic” window

5. Move “Speed Control” slider 6. Check OUT1/2 state

Table 2: Desired Results

OUT1/2 = PWM duty-cycle per Duty slider position LED1 on, LED2 off, LED3 off, LED4 off

Test procedure Step 4 (PC Mode, HS2 + LS1 on):

1. Click “Stop” button in “Basic” window

2. Click “Run Backward” button in “Basic” window 3. Move “Speed Control” slider

4. Check OUT1/2 state

Table 3: Desired Results

OUT1/2 = PWM duty-cycle per Duty slider position LED1 on, LED2 off, LED3 off, LED4 off

DC Characteristics

MIN TYP MAX

VCC ON 4.9 V 5 V 5.1 V

IBAT_SA (H-bridge off) 24 mA

VCHP, Active mode VBAT + 8 V VBAT + 10 V VBAT + 12 V

OUTx LS 0.1 V

OUTx HS VBAT – 0.1 V

Vsen_off 0 mV 100 mV

Vsen_on 200 mV 250 mV 300 mV

参照

関連したドキュメント

 To evaluate SIM_I/O, an I/O signal accommodating the datasheet specifications will be applied directly to the NCN4555 I/O device input (using either the

Connect the test setup as shown in Figure 4 and verify J3 and J5 jumpers are left open as illustrated.. Use the function generator to generate a 1 kHz PWM signal with a low level of

NOTE: Unless otherwise specified, all voltage measurements are taken at the terminals of the UUT1. Test

Check OUT1/2 state Table 2: Desired Results.. OUT1/2 = PWM duty-cycle per Duty

If no precautions are taken, it is likely that the voltage drop at the load cables ends induces a

 If the load does not use local Kelvin sensors, then the output voltage must be measured at the board level, not at the cable ends... Board

False triggers test: Turn the lens away from IR radiating sources (humans and living things). Keep the device stable with your hand. Do this for at least 15seconds. If the LED

Connect the electronic load with high voltage module to the output labeled “400 V, 100 W”.. Connect one of the multimeters in series with the output and load and set it to measure