• 検索結果がありません。

CT 検査における個人の体型を反映した被ばく線量評価法の開発

N/A
N/A
Protected

Academic year: 2021

シェア "CT 検査における個人の体型を反映した被ばく線量評価法の開発"

Copied!
2
0
0

読み込み中.... (全文を見る)

全文

(1)

኱ศ┴❧┳ㆤ⛉Ꮫ኱Ꮫ኱Ꮫ㝔 Ặ     ྡ   ட஭࠿ ࡵ ࠸ ಟ࠾ࡉࡴ Ꮫ ఩ ࡢ ✀ 㢮   ༤ኈ㸦೺ᗣ⛉Ꮫ㸧 Ꮫ ఩ グ ␒ ྕ   ➨ 11 ྕ Ꮫ఩ᤵ୚ᖺ᭶᪥   ᖹᡂ 27 ᖺ 3 ᭶ 18 ᪥ Ꮫ఩ᤵ୚ࡢせ௳   Ꮫ఩つ๎➨㸲᮲➨ 1 㡯ヱᙜ⪅ ┳ㆤᏛ◊✲⛉೺ᗣ⛉Ꮫᑓᨷ Ꮫ ఩ ㄽ ᩥ ྡ   CT ᳨ᰝ࡟࠾ࡅࡿಶேࡢయᆺࢆ཯ᫎࡋࡓ⿕ࡤࡃ⥺㔞ホ౯ἲࡢ㛤Ⓨ

          Development of dose-evaluation methods in CT examinations with considering individual physical size

ᣦ ᑟ ᩍ ဨ   ⏥ᩫ ೔᫂ᩍᤵ(୺) ᑠᔱ ග᫂ㅮᖌ(๪) ㄽ ᩥ ᑂ ᰝ ጤ ဨ   ୺ᰝ㸸బ఑ᆂ୍㑻ᩍᤵ ๪୺ᰝ㸸ရᕝె‶෸ᩍᤵ࣭๓⏣ᚭ┴❧⑓㝔๪㝔㛗 ㄽ ᩥ ෆ ᐜ ࡢ せ ᪨  ࠙┠ⓗࠚCT ⿦⨨ࡢ฼⏝ࡀ㐍ࡴ୰ࠊ⿕ࡤࡃ⥺㔞ࡢቑຍࡀ༴᝹ࡉࢀ࡚࠸ࡿࠋࡑࡇ࡛ࠊCT ᳨ᰝ᫬࡟࠾ࡅ ࡿேయ⮚ჾࡢ⿕ࡤࡃ⥺㔞ࢆ᥎ᐃࡍࡿࡓࡵ࡟ࠊࣔࣥࢸ࢝ࣝࣟἲࢆ฼⏝ࡋࡓࠊImPACT ἲࡸ CT-EXPO ἲࡀ㛤Ⓨࡉࢀ฼⏝ࡉࢀ࡚᮶ࡓࠋࡋ࠿ࡋࠊࡇࡢࢶ࣮ࣝ࡟࠾ࡅࡿ⥺㔞ホ౯ࡣḢ⡿ேࡢయ᱁࡟࠾ࡅࡿ⥺㔞࡛ ࠶ࡾࠊయ᱁ࡢᑠࡉ࠸᪥ᮏேࡢሙྜ࡟ࡣ⥺㔞᥎ᐃ್࡟ㄗᕪࢆ⏕ࡌࡿ࡜⪃࠼ࡽࢀࡿࠋࡲࡓࠊ౑⏝ࡍࡿࣇ࢓ ࣥࢺ࣒ࡣᩘᘧ࡛సᡂࡉࢀࡓయᆺ࡛࠶ࡾࠊᐇ㝿ࡢேయࡢ⮚ჾ࡟ᑐࡋ࡚ࡢ⥺㔞ホ౯࡛ࡣ࡞࠸ࠋ ᪥ᮏ࡟࠾࠸࡚ࡣࠊ኱ศ┴❧┳ㆤ⛉Ꮫ኱Ꮫ࡜᪥ᮏཎᏊຊ◊✲㛤Ⓨᶵᵓ࡛ඹྠ㛤Ⓨࡉࢀࡓ WAZA-ARI ࡜࠸࠺⥺㔞ィ⟬ Web ࢩࢫࢸ࣒ࡀᐇ⏝໬ࡉࢀ࡚࠸ࡿࠋࡇࡢࢩࢫࢸ࣒࡛ࡣ᪥ᮏேࡢᶆ‽యᆺ࡛ࡢ⥺㔞ホ ౯ࢆ⾜࠺ࡓࡵࠊ᪥ᮏཎᏊຊ◊✲㛤Ⓨᶵᵓ࡟࠾࠸࡚㛤ⓎࡉࢀࡓࠊࠕJM-103ࠖࠊࠕJF-103ࠖ࡞࡝ࠊࡼࡾ᪥ ᮏேࡢᶆ‽యᆺ࡟㏆࡙ࡅࡓ࣎ࢡࢭࣝࣇ࢓ࣥࢺ࣒ࢆ౑⏝ࡋ࡚ࠊPHITS ࢥ࣮ࢻ࡟ࡼࡿࣔࣥࢸ࢝ࣝࣟἲࢆ ฼⏝ࡋࡓ⮚ჾࡢ⥺㔞ホ౯ࢆ⾜ࡗ࡚࠸ࡿࠋ౑⏝ࡋࡓ᪥ᮏேࡢᶆ‽యᆺࡣࠊ⏨ᛶࡣ㌟㛗 171cmࠊయ㔜 65kg 㸦JM-103㸧ࠊࡲࡓዪᛶࡣ㌟㛗 155cmࠊయ㔜 52kg㸦JF-103㸧࡛࠶ࡿࠋࡋ࠿ࡋ࡞ࡀࡽࡇࡢ WAZA-ARI ࡟࠾ࡅࡿ᥎ᐃ⥺㔞࡟࠾࠸࡚ࡶᶆ‽యᆺ࡟࠾ࡅࡿ⮚ჾ⥺㔞ࡢホ౯࡛࠶ࡾࠊᐇ㝿ࡢ⮫ᗋ࡟࠾ࡅࡿಶูࡢయ ᆺࢆ཯ᫎࡋࡓ⥺㔞ホ౯࡛ࡣ࡞࠸ࠋࡋࡓࡀࡗ࡚ṇ☜࡞⮚ჾ⥺㔞ࢆ⟬ᐃࡍࡿࡓࡵ࡟ࡣࠊJM ࠾ࡼࡧ JF ࣇ ࢓ࣥࢺ࣒࡜ᐇ㝿ࡢయᆺ࡜ࡢᕪ࠿ࡽ⏕ࡎࡿㄗᕪࢆ⿵ṇࡍࡿ᪉ἲࡢ㛤Ⓨࡀᚲせ࡛࠶ࡿࠋࡑࡇ࡛ࠊᮏ◊✲࡛ ࡣࠊࡇࢀࡲ࡛◊✲ࡉࢀ࡚ࡁࡓ WAZA-ARI ࡞࡝ࡢ◊✲ᡂᯝࢆࡩࡲ࠼࡚ࠊ⮫ᗋ࡛㐼㐝ࡍࡿ᪥ᮏேࡢ୍⯡ ⓗ࡞యᆺ࡟࠾࠸࡚ࠊ⮚ჾ⥺㔞ࡢ⿵ṇ᪉ἲࢆ㛤Ⓨࡍࡿࡇ࡜ࢆ┠ⓗ࡜ࡋ࡚࠸ࡿࠋ ࠙◊✲ 1ࠚ⮫ᗋ CT ᳨ᰝࢹ࣮ࢱ࠿ࡽࠊJMࠊJF ࣇ࢓ࣥࢺ࣒࡜ྠ➼࡞యᆺ࠾ࡼࡧ⑭ࡏᙧࠊኴࡾᆺࡢయᆺ ࢆ᭷ࡍࡿࠊ⏨ᛶ 11 యࠊዪᛶ 10 యࢆ↓సⅭ࡟㑅ࡧࠊࡑࢀࡽࡢయᆺ㸦APࠊLATࠊ࿘ᅖ㛗࡞࡝㸧ࢆ⮬స ࡢ CT ࢹ࣮ࢱ࣎ࢡࢭࣝኚ᥮ࢶ࣮ࣝࡢయᆺィ ᶵ⬟ࢆ౑⏝ࡋ࡚ィ ࡋࡓࠋேయࡢయᆺㄪᰝ࡟ࡘ࠸࡚ࡣࠊ ࡇࢀࡲ࡛ከࡃࡢ◊✲ࡀ࡞ࡉࢀ࡚࠾ࡾࠊᚑ᮶࠿ࡽయ㔜࡜ AP㸪LATࠊ࿘ᅖ㛗➼ࡢ㛵ಀࡢẚ㍑ࡀ࡞ࡉࢀ࡚ ࠸ࡿࠋᮏ◊✲࡛ࡣࠊࡑࢀࡽࡢ᪉ἲ௨እ࡟ࡶࠊBMI ࡸ᭷ຠ┤ᚄ㸦ED㸧࡜࠸࠺ᣦᶆࢆ⟬ᐃࡋࠊࡑࢀࡽࡢ ᩘ್࡜ࡢ㛵ಀࢆㄪ࡭ࡓࠋࡲࡓࠊ⮫ᗋࢹ࣮ࢱ࠿ࡽ⫵ࠊᚰ⮚ࠊ⫶ࠊ⫢⮚ࠊ⫹ࡢ࠺ࠊ⭈⮚ࠊ⮅⮚ࠊ⭁⮚ࠊ⭤ ⬔ࠊᏊᐑ࡞࡝ࡢྛ⮚ჾࡢయ✚ࢆィ ࡋࠊయ㔜࡜ࡢ㛵ಀࢆศᯒࡋࡓࠋࡑࡢ⤖ᯝࠊ⏨ᛶࡢሙྜࠊ⮚ჾ࡜య 㔜ࡢ㛫࡟᭷ព࡞㛵ಀᛶࡣㄆࡵࡽࢀ࡞࠿ࡗࡓࠋࡋ࠿ࡋࠊዪᛶࡢሙྜ࠸ࡃࡘ࠿ࡢ⮚ჾ㸦⫹ࡢ࠺ࠊ⭈⮚ࠊ⭁ ⮚ࠊ⭤⬔㸧࡟࠾࠸࡚ࠊయ㔜࡜⮚ჾయ✚ࡢ㛫࡟୍ᐃࡢ㛵ಀᛶࡀㄆࡵࡽࢀࡓࠋ ࠙◊✲ 2ࠚᮏ◊✲ࡢ᭱⤊┠ᶆ࡛࠶ࡿయᆺࡢ㐪࠸࡟ࡼࡿ⥺㔞ホ౯ࡣࠊPHITS ࢥ࣮ࢻୖ࡛ࠊCT ⿦⨨ࢆᵓ ⠏ࡋࠊ᭦࡟๓㏙ࡋࡓ⮫ᗋࢹ࣮ࢱ࠿ࡽసᡂࡋࡓேయ࣎ࢡࢭࣝࣇ࢓ࣥࢺ࣒࡟ᑐࡋ࡚ X ⥺↷ᑕࢆ⾜࠺ࢩ࣑ ࣮ࣗࣞࢩࣙࣥࢆᐇ᪋ࡋ࡚ࠊேయࡢྛ⮚ჾࡢ⿕ࡤࡃ⥺㔞ࡢ᥎ᐃࢆ⾜ࡗࡓࠋࡇࢀࡽࡢㄪᰝ࠾ࡼࡧᐇ㦂࡟ࡼ ࡿ⤖ᯝ࡜ࡋ࡚ࠊᡂே᪥ᮏே⏨ዪࡢయᆺࡢ≉ᚩ࠿ࡽࠊ᪥ᮏேᶆ‽࡛࠶ࡿ JMࠊJF ࣇ࢓ࣥࢺ࣒࡜⮫ᗋࢹ ࣮ࢱ࠿ࡽࠊ᭷ຠ┤ᚄ(ED)࡜ CT ᳨ᰝ᫬ࡢ⮚ჾ⥺㔞࡜ࡢ㛵ಀᛶࢆ᫂ࡽ࠿࡟ࡍࡿࡇ࡜ࡀ࡛ࡁࡓࠋࡲࡓࠊ JMࠊJF ࣇ࢓ࣥࢺ࣒ࡢ⮚ჾ⥺㔞ࡢ್࡜⮫ᗋࢹ࣮ࢱࡢ⮚ჾ⥺㔞ࡢẚ㍑ࢆ⾜࠸ࠊ᪥ᮏேᶆ‽࡛࠶ࡿ JMࠊ JF ࣇ࢓ࣥࢺ࣒ࡢ⮚ჾ⥺㔞ࡀࡶࡘಶேయᆺࡢ㐪࠸ࡀࡶࡓࡽࡍㄗᕪࡢ᥎ᐃࢆ⾜࠺ࡇ࡜ࡀ࡛ࡁࡓࠋ ࠙⤖ㄽࠚᮏ◊✲ࡢ⤖ᯝࠊJMࠊJF ࣇ࢓ࣥࢺ࣒࡜యᆺࡢ␗࡞ࡿ⮫ᗋ࡟࠾ࡅࡿ⿕᳨⪅ࡢ CT ᳨ᰝ᫬ࡢࠊ⮚ ჾ⿕ࡤࡃ⥺㔞ࢆs10%௨ෆ࡛᥎ᐃࡍࡿࡇ࡜ࡀྍ⬟࡛࠶ࡿࡇ࡜ࢆ♧ࡋࡓࠋ⏨ዪࡢయᆺࡣ␗࡞ࡿࡀࠊ⮚ჾ ⥺㔞࡜᭷ຠ┤ᚄ࡜ࡢ㛵ಀࡣࠊ⏨ዪࡢ㐪࠸ࡣ᭷ព࡞ࡶࡢ࡛ࡣ࡞࠸ࡓࡵࠊ⮚ჾ⥺㔞ࢆ᥎ᐃࡍࡿ㝿࡟ࡣࠊ᭷ ຠ┤ᚄࢆ⏝࠸࡚ᶆ‽ࣇ࢓ࣥࢺ࣒ࡢ⮚ჾ⥺㔞࡟ᑐࡋ࡚⏨ዪྠ୍ࡢ⿵ṇᘧࢆ฼⏝ࡍࡿࡇ࡜ࡀ࡛ࡁࡿࡇ࡜ ࢆ♧ࡋࡓࠋ

(2)

኱ศ┴❧┳ㆤ⛉Ꮫ኱Ꮫ኱Ꮫ㝔

Abstract



࠙ObjectiveࠚIn this study, it aims to develop correction coefficients for estimating organ doses to patients of any size attended to daily clinical practice. These results can be used for computer tomography (CT) dose calculators such as WAZA-ARI.

࠙Study 1ࠚWe randomly selected 11 males and 10 females from the clinical data with different body size from the average Japanese size like the JM and JF phantom. The body size can be characterized by AP, LAT and perimeter measured by using a voxel-conversion tool for CT image data. Since there are a number of studies for categorization of human body types so far, the relation with weight, AP, LAT, and perimeter has been already compared. This study calculated the indexes called BMI and effective diameter (ED) for each patient other than previous methods, and then examined the relation of those calculated values with organ sizes. Furthermore, this study also measured the volume of each organ from the clinical data such as lung, heart, stomach, liver, gallbladder, kidney, pancreas, spleen, urinary bladder, and womb, and analyzed their relations with body weights. As a result, no significant relation was observed between organs volumes and body weights in males. In females, however, a statistically significant relation was observed between body weights and organ volumes only in several organs, gallbladder, kidney, spleen, and urinary bladder.

࠙Study 2ࠚCalculation of organ doses was conducted by the Monte-Carlo simulations using a PHITS code where X-ray was irradiated against human voxel phantoms by structuring a quasi-CT scanner. As the results of the Monte-Carlo simulations, we analyzed the relation between organ doses and ED in JM, JF and patient phantoms, and obtained the equations for predicting patient-specific organ doses using ED. In addition, we compared patient-specific organ doses with the ED-modified organ doses given by the WAZA-ARI that uses the JM and JF phantoms with average Japanese sizes. The difference in males was approximately 10% in the stomach and less than 7% in other organs. The ED-based equation by combining males and females provided a better agreement with the average errors of -4.8% in females and -6.2% in males. However, in some cases, ED-based prediction was inconsistent with patient-specific organ doses, particular in heart and stomach. It was found that the size of the lung largely influenced x-ray transport and consequently the organ doses departed from the ED-based prediction.

࠙ConclusionࠚThis study provided how to patient-specific organ doses from adult body CT scans for a patient with the different body size from JM and JM phantom with an error of ±10% or lower.

   ㄽ ᩥ ᑂ ᰝ ࡢ ⤖ ᯝ ࡢ せ ᪨    &7᳨ᰝ᫬ࡢ⿕ࡤࡃ⥺㔞ࡢホ౯ἲࢆᨵၿࡍࡿࡓࡵࠊேయࡢᶆ‽ⓗ࡞ᩘ್ࣔࢹࣝ㸦ࣇ࢓ࣥࢺ࣒㸧ࢆ⏝࠸ ࡿᚑ᮶ࡢࢥࣥࣆ࣮ࣗࢱࢩ࣑࣮ࣗࣞࢩࣙࣥ࡟ࡼࡿ᥎ᐃ್࡟ᑐࡋ࡚ಶேࡢయᆺࡢᕪ␗࡟ࡼࡿ⿵ṇࢆヨࡳ ࡓ◊✲࡛࠶ࡿࠋ་⒪⿕ࡤࡃ࡟㛵ࡍࡿ㆟ㄽࡢ๓ᥦ࡜ࡋ࡚㸪ᝈ⪅ಶேࡢ⿕ࡤࡃ⥺㔞ࢆ⢭ᐦ࡟ホ౯ࡍࡿࡇ࡜ ࡣ㔜せ࡛࠶ࡾࠊᮏ◊✲ࡢ┠ᣦࡍࡶࡢࡢព⩏ࡣ኱ࡁ࠸ࠋᮏㄽᩥࡢ୰ᚰࡣ㸪ᵝࠎ࡞యᆺࡢࣇ࢓ࣥࢺ࣒ࢆ⏝ ࠸ࠊ3+,76ࢥ࣮ࢻ࡟ࡼࡿ⿕ࡤࡃ⥺㔞᥎ᐃ್࡜యᆺࢆ௦⾲ࡍࡿ㌟యィ 㡯┠⩌࡜ࡢ㛵㐃ࢆᅇᖐศᯒ࡛ゎ ᯒࡍࡿࡇ࡜࡛ࠊᝈ⪅⬚⭡㒊ࡢ᭷ຠ┤ᚄࢆ⏝࠸ࡓ⿵ṇ᪉ἲࡀࡶࡗ࡜ࡶ᭷ຠ࡛࠶ࡿࡇ࡜ࢆ♧ࡋࡓ㒊ศ࡛࠶ ࡿࠋࡲࡓࠊࡑࡢ๓ẁ㝵࡜࡞ࡿᵝࠎ࡞యᆺࢆᣢࡘ⏨ዪィྡࡢ&7⏬ീࢆゎᯒࡋࠊ⮚ჾࡢ✀ูࡸ఩⨨ࢆᩘ ್ࢹ࣮ࢱ࡟ኚ᥮ࡋ㸪ࢩ࣑࣮ࣗࣞࢩࣙࣥ⏝ࡢࣇ࢓ࣥࢺ࣒ࢆᵓ⠏ࡍࡿ㒊ศࡣ㸪ከ኱࡞᫬㛫ࢆせࡍࡿປస࡛ ࠶ࡿ࡜࡜ࡶ࡟ࠊ⮚ჾࡢ఩⨨ࡸ኱ࡁࡉࡢࢹ࣮ࢱ࡜ࡑࡢศᯒ࡜ࡋ࡚ࡶ⯆࿡῝࠸ࡶࡢ࡛࠶ࡿࠋ  ௒ᚋࡣ㸪◊✲ᡂᯝࡢ⮫ᗋ࡟࠾ࡅࡿ᳨ᰝ᫬ࡢ⿕ࡤࡃ⥺㔞グ㘓ࢩࢫࢸ࣒࡬ࡢᑟධ࡜㸪యᆺࢹ࣮ࢱᩘ್໬ ࡢᡭἲࢆࡉࡽ࡟ᨵၿࡋࠊయᆺࢹ࣮ࢱࢆ㏣ຍࡍࡿࡇ࡜࡟ࡼࡿಶே⿕ࡤࡃ⥺㔞᥎ᐃࡢ᭦࡞ࡿ⢭ᗘྥୖࢆᮇ ᚅࡍࡿࡶࡢ࡛࠶ࡿࡀࠊࡇࡢ◊✲ㄽᩥ࡛ࡢᡂᯝࡣ㸪ᮏᏛࡢ೺ᗣ⛉Ꮫᑓᨷ༤ኈᚋᮇㄢ⛬ࡢᏛ఩ㄽᩥ࡜ࡋ࡚ ༑ศ࡟┦ᛂࡋ࠸ࡶࡢ࡜ุ᩿ࡍࡿࠋ 

参照

関連したドキュメント

過水タンク並びに Sr 処理水貯槽のうち Sr 処理水貯槽(K2 エリア)及び Sr 処理水貯槽(K1 南エリア)の放射能濃度は,水分析結果を基に線源条件を設定する。RO

過水タンク並びに Sr 処理水貯槽のうち Sr 処理水貯槽(K2 エリア)及び Sr 処理水貯槽(K1 南エリア)の放射能濃度は,水分析結果を基に線源条件を設定する。RO

1 100超え 191 75超え~100以下 233 50超え~75以下 267 20超え~50以下 186 10超え~20以下 129 5超え~10以下 145 1超え~5以下 51 1以下 1203 計 102.69

・ 各吸着材の吸着量は,吸着塔のメリーゴーランド運用を考慮すると,最大吸着量の 概ね

調査の結果を反映し、IoT

線量は線量限度に対し大きく余裕のある状況である。更に、眼の水晶体の等価線量限度について ICRP の声明 45 を自主的に取り入れ、 2018 年 4 月からの自主管理として

活断層の評価 中越沖地震の 知見の反映 地質調査.

るものとし︑出版法三一条および新聞紙法四五条は被告人にこの法律上の推定をくつがえすための反證を許すもので