• 検索結果がありません。

JAIST Repository: Nanoscale metal transistor control of Fowler-Nordheim tunneling currents through 16 nm insulating channel

N/A
N/A
Protected

Academic year: 2021

シェア "JAIST Repository: Nanoscale metal transistor control of Fowler-Nordheim tunneling currents through 16 nm insulating channel"

Copied!
6
0
0

読み込み中.... (全文を見る)

全文

(1)

Japan Advanced Institute of Science and Technology

JAIST Repository

https://dspace.jaist.ac.jp/

Title

Nanoscale metal transistor control of Fowler-Nordheim tunneling currents through 16 nm insulating channel

Author(s) Fujimaru, Kouji; Sasajima, Ryouta; Matsumura, Hideki

Citation Journal of Applied Physics, 85(9): 6912-6916 Issue Date 1999-05-01

Type Journal Article

Text version publisher

URL http://hdl.handle.net/10119/4542

Rights

Copyright 1999 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Kouji Fujimaru, Ryouta Sasajima, Hideki Matsumura, Journal of Applied Physics, 85(9), 6912-6916 (1999) and may be found at

http://link.aip.org/link/?JAPIAU/85/6912/1 Description

(2)
(3)
(4)
(5)
(6)

参照

関連したドキュメント

Further- more, as an application of a refined version of the arithmetic Riemann- Roch theorem, we show that the above current, when restricted to a torsion section, is the

Where a rate range is specified, the higher rates should be used (a) in fields with a history of severe weed pressure, (b) when the time between early preplant tank mix and

In tank mixes with one or more of the following herbicides for between crop applications, apply 4 –16 fluid ounces of VISION™ per acre for control of annual weeds, or 16 – 32

Flexstar GT 3.5 may be applied as a preplant or preemergence burndown application in cotton or as a postemergence directed application in glyphosate-tolerant (GT) cotton* and as

Reduced rates (8 to 16 ounces of Establish per acre) may be used where partial control or reduced length of soil residual control is required, such as

In tank mixes with one or more of the following herbicides, apply 4 - 16 fluid ounces of Clarity per acre for control of annual weeds, or 16 - 32 fluid ounces of Clarity per acre

TriCor 4F herbicide tank mix combinations are recommended for preplant incorporated applications, pre-emergence surface applications, Split-Shot application and Extended

Refer to crop specifi c application directions in this label for specifi c application information for each crop in each region including the maximum yearly application rate,