• 検索結果がありません。

Test Procedure for the AXDBG-2-GEVK Evaluation Board 1 Requirements

N/A
N/A
Protected

Academic year: 2022

シェア "Test Procedure for the AXDBG-2-GEVK Evaluation Board 1 Requirements"

Copied!
4
0
0

読み込み中.... (全文を見る)

全文

(1)

3/15/2017 1 www.onsemi.com

Test Procedure for the AXDBG-2-GEVK Evaluation Board

1 Requirements

 Windows computer or laptop

 AXSDB (part of the AXSEM IDE)

 F143 MOD A or B

2 Visual inspection

1. Are all required parts assembled?

2. Pinheader mounted correctly?

3. All 4 jumpers mounted? (if not, mount them manually)

(2)

3/15/2017 2 www.onsemi.com

3 Programming

1. Connect the AXDBG to a computer (the first time Windows requires some time to install drivers) 2. Open a Command terminal CMD

3. Execute: axftdieeprog -p -f -s 3

4. Unplug and re-plug the AXDBG (required for Windows to recognize the newly installed Software)

4 Testing

1. Connect a F143-MINI-A-MOD or F143-MINI-B-MOD to the AXDBG 2. Execute: axsdb --flashprog \path\to\file\sendCW.omf

Desired output:

axsdb --flashprog sendCW.omf Programming Serial 00000003 Bulk erase...

Flash program...

Run program...

(3)

3/15/2017 3 www.onsemi.com 3. Check the red LED, it should be illuminated during the programming

4. Check the green LED, it should flash shortly after programming

5 Packaging

 If all test are passed the AXDBG get sealed in 3” x 5” ESD bags (size is not critical)

6 Boxing

Note: AXDBG is also part of most other DVK's, therefore only a small portion of the AXDBG gets packaged in boxes and sent to Singapore.

Box: Rajapack RPT102 Contents:

1. AXDBG

2. Mini USB to USB cable 3. Flat ribbon cable

4. Disclaimer, OnSemi logo is on top, first thing to see if box is opened

(4)

3/15/2017 4 www.onsemi.com

参照

関連したドキュメント

Test Procedure for the Measurement of Load Regulation parameter using Test Setup 1:1. Connect the test setup as shown on

False triggers test: Turn the lens away from IR radiating sources (humans and living things). Keep the device stable with your hand. Do this for at least 15seconds. If the LED

*Note – Be carefully if any device is connected on output, because leakage current can affect measurement accuracy... Apply voltage at

Equipment needed: Power supply #1 for +5V power, 1A capability; power supply #2 for input voltage, variable from ~6 V to 25 V, minimum 3 A capability; oscilloscope, minimum of

Input current transitions should be located near to the point where driver board AC input voltage crosses 56V (one LED string forward voltage, as all four LED strings

Set the function generator 20 to 30 kHz higher than the switching frequency measured in step 7 of Normal Operation.. Disable the generator’s output and connect it to SYNC and GND

(1) Before making any connections, make sure to set the power supplies for input voltage, controller and the driver voltage at 0V. Also make sure that the load current is

The ‘’Dynamic Tmin Settings’ window allows the user to configure the ADT7462 to control the fans based on a specific operating point temperature (see figure 12). The options