(1)

Test Procedure for the NCP1530 Demonstration Board

6/9/2004

Adjust Agilent E3632A

+S + - -S

Agilent 34401A

MULTIMETER

<

DCV

ON

> OFF ACV

w

OHM FREQ

LO LO

KIKUSUI

<

POWER

PLZ153W

>

IOUT = 1mA ~ 600mA

2.5V 2.7V 3.0V 3.3V

VOUT =

(2)

Table 1: Required Equipment

One NCP1530 Evaluation Board Agilent 34401A Multimeter Agilent E3632A Power Supply KIKUSUI PLZ153W Load Four Black Test Leads Four Red Test Leads

Test Procedure:

1. Connect the test setup as shown above.

2. JP1 = OFF → Auto Mode

3. JP2 = OFF → Enable the device

4. Apply an input voltage, VIN = VSET + 1.0 V across T1 and T2.

5. Apply 100 mA loading from the electronic load after power up the demo board.

6. Check IIN, VOUT, and output ripple. It should match the desired results as shown below in Table 2.

(3)

Table 2: Desired Results IIN ≈ 80 mA to 83.3 mA

VOUT ≈2.46 V to 2.54 V For 2.5V devices,

VRIPPLE ≈ 10 mVP-P

IIN ≈ 81.6 mA to 83.4 mA VOUT ≈ 2.69 V to 2.72 V For 2.7V devices,

VRIPPLE ≈ 10 mVP-P

IIN ≈ 83.2 mA to 86 mA VOUT ≈ 2.98 V to 3.03 V For 3.0V devices,

VRIPPLE ≈ 11 mVP-P

IIN ≈ 83.42 mA to 87 mA VOUT ≈ 3.26 V to 3.33 V For 3.3V devices,

VRIPPLE ≈ 13 mVP-P

参照

関連したドキュメント

Setup Procedure: Set the equipment as shown in the diagram below so that the input and output voltage and current to the demo board can be measured and the output ripple can

- Write demanded value to relevant box and press Enter (in this case Voltage amplitude 20 and frequency 1, current with amplitude almost 1A and frequency 1Hz after motor start

Check OUT1/2 state Table 2: Desired Results.. OUT1/2 = PWM duty-cycle per Duty

False triggers test: Turn the lens away from IR radiating sources (humans and living things). Keep the device stable with your hand. Do this for at least 15seconds. If the LED

*Note – Be carefully if any device is connected on output, because leakage current can affect measurement accuracy... Apply voltage at

Board Window: Check Status bits and Motor Current and Supply.. Table 5: Desired Results

Equipment needed: Power supply #1 for +5V power, 1A capability; power supply #2 for input voltage, variable from ~6 V to 25 V, minimum 3 A capability; oscilloscope, minimum of