Test Procedure for the NCP1530 Demonstration Board
6/9/2004
Adjust Agilent E3632A
+S + - -S
Agilent 34401A
MULTIMETER
<
DCV
ON
> OFF ACV
w
OHM FREQ
LO LO
KIKUSUI
<
POWER
PLZ153W
>
IOUT = 1mA ~ 600mA
2.5V 2.7V 3.0V 3.3V
VOUT =
Table 1: Required Equipment
One NCP1530 Evaluation Board Agilent 34401A Multimeter Agilent E3632A Power Supply KIKUSUI PLZ153W Load Four Black Test Leads Four Red Test Leads
Test Procedure:
1. Connect the test setup as shown above.
2. JP1 = OFF → Auto Mode
3. JP2 = OFF → Enable the device
4. Apply an input voltage, VIN = VSET + 1.0 V across T1 and T2.
5. Apply 100 mA loading from the electronic load after power up the demo board.
6. Check IIN, VOUT, and output ripple. It should match the desired results as shown below in Table 2.
Table 2: Desired Results IIN ≈ 80 mA to 83.3 mA
VOUT ≈2.46 V to 2.54 V For 2.5V devices,
VRIPPLE ≈ 10 mVP-P
IIN ≈ 81.6 mA to 83.4 mA VOUT ≈ 2.69 V to 2.72 V For 2.7V devices,
VRIPPLE ≈ 10 mVP-P
IIN ≈ 83.2 mA to 86 mA VOUT ≈ 2.98 V to 3.03 V For 3.0V devices,
VRIPPLE ≈ 11 mVP-P
IIN ≈ 83.42 mA to 87 mA VOUT ≈ 3.26 V to 3.33 V For 3.3V devices,
VRIPPLE ≈ 13 mVP-P