• CC-Link master/local module
• MELSECNET/10 network module
• Ethernet module
• Computer link module etc.
• After replacing the module, use the parameter I/O assignment and set so that the existing module addresses
• The QA6B extension base unit and QA1S6B extension base units are only compatible with the Universal
• For precautions and restrictions when using QA6B extension base unit, refer to "QA65B/QA68B Extension
A38B
Empty
Q61P Q06UDH CPU QJ61BT 11N QJ71 BR11 QJ71E71 -100 Empty
A61P AX41 Empty AY10 A68AD A68AD A68DAI-S1 Empty Empty
Q35B
QA68B QC06B
Modules upgraded from the A Series
Empty slots for replacing to Q Series module Existing A Series
modules
• The QA6B extension base unit permits reuse of existing A (Large Type) Series modules, minimizing wiring time.
• The system can be upgraded even if Q Series compatible modules do not exist.
Solution and Benefit
A61P A3NCPU AX41 AJ61BT11 AY10 A68AD A68AD A68DAI-S1 AJ71BR11 AJ71E71N3-T
(1) System configuration example
Current configuration After replacement
Replace
3.1 Replace A/QnA (Large Type) Series with Q Series
Product name
Power supply module (for main base unit) N/A - Q61P
Existing module Replacement module 1
CPU module A3NCPU 1 Q06UDHCPU 1
Main base unit A38B 1 Q35B 1
CC-Link master module AJ61BT11 1 QJ61BT11N 1
MELSECNET/10 network module AJ71BR11 1 QJ71BR11 1
Ethernet module AJ71E71N3-T 1 QJ71E71-100 1
Extension base unit N/A - QA68B 1
Power supply module (for extension base unit) A61P 1 Utilize existing module
-Extension cable N/A - QC06B 1
Input module AX41 1 Utilize existing module
-Output module AY10 1 Utilize existing module
-Analog input module A68AD 2 Utilize existing module
-Analog output module A68DAI-S1 1 Utilize existing module
-●
Utilize A/QnA (Large Type) Series QA6B extension base unit
• The following A (Large Type) modules cannot be used with QCPU.
These modules must be replaced with those compatible with QCPU.
• CC-Link master/local module
• MELSECNET/10 network module
• Ethernet module
• Computer link module etc.
• After replacing the module, use the parameter I/O assignment and set so that the existing module addresses are not changed.
• The QA6B extension base unit and QA1S6B extension base units are only compatible with the Universal Model QCPU (first five digits of serial No. "13102" or higher). The Process CPUs, Redundant CPUs, Safety CPUs, and Remote I/O Stations are not compatible.
• For precautions and restrictions when using QA6B extension base unit, refer to "QA65B/QA68B Extension Base Unit User's Manual".
• The QA6
• T
Replace
Tip
(2) Module selection example
3.1 Replace A/QnA (Large Type) Series with Q Series
* The extension stage number of the QA conversion adapter should be set in accordance with that of the extension base unit.
• The existing A (Large type) Series extension base unit and mounted modules can be utilized without wiring The existing A (Large Type) Series extension base unit can be used without modifying the wiring by repl with the extension base QA6B, and remounting the mounted modules.
• Prog
• wing A (Large Type) Series module cannot be used with the Q Series CPU. These must be changed CC-Link master/local module
MELSECNET/10 network module Ethernet module, computer link module
• The A (Large Type) Series A6B/A5B extension base unit with the QA6ADP cannot be used together with the QA1S6B extension base unit.
• When an AC input module is mounted on the "A5B" extension base unit (without power supply) using the QA6ADP, either the "A6B with QA6ADP" or "QA6B" extension base unit (with power supply) is required in
• Set th
• The QA6ADP QA conversion adapter is only compatible with Universal Model QCPU (first five digits of serial Process CPUs, Redundant CPUs, Safety CPUs, and Remote I/O Stations are not compatible.
• For the precautions and restrictions when using QA conversion adapter, refer to "QA6ADP QA Conversion A35B
A61P A3ACPU AX42
X00...
AX42 AX42 AX42 AX42 Q61P Q03UD CPU
Q35B
The QA conversion adapter module enables the existing extension base, including the mounted I/O modules, to connect to a Q Series main base unit. This can shorten the installation and wiring modification times.
Solution and Benefit
The following is an example of reusing existing A (Large Type) Series modules with a Q Series CPU using the QA conversion adapter module.
● Instructions
(1) Replace the A (Large Type) Series CPU with the Q Series CPU (Q03UDCPU) and mount it on the Q Series main base unit (Q3B).
(2) To reutilize I/O modules mounted on the existing A (Large Type) Series main base unit, mount them on the QA6B extension base unit.
(3) Mount the "QA6ADP" adapter on the connector of each existing extension base unit to allow the use of existing modules.
(4) Connect the base units with the Q Series extension cable (QCB).
A65B
A61P AX41
X140...
AY42
AX41 AY42 AY42
Extension base stage 1
A65B
A61P
Extension base stage 2
AY42
Y240...
AY42
AY42 AY41 AY41
QA65B
A61P AX42
X00...
AX42
AX42 AX42 AX42
Extension base stage 1
A65B
A61P
Extension base stage 2
AX41 AY42
AX41 AY42 AY42
A65B
A61P
Extension base stage 3 AC06B
AC06B
QC06B
QC06B
QC06B
AY42 AY42
AY42
X140...
*
*
Y240...
AY41 AY41
QA6 ADP
QA6 ADP Replace the A (Large Type)
CPU with a QCPU
Utilize the modules and extension base unit.
Utilize the modules and extension base unit.
The adapter allows the A (Large Type) Series extension base unit to be used as the QCPU's extension base unit. (Max. 7 extension stages) Remount the
modules on the QA6B.
Q Series modules are mountable
Current configuration After replacement
●
(1) System configuration example
Extension stage
number setting: 2nd stage
Extension stage
number setting: 3rd stage
3.1.2 Utilize existing I/O modules and extension base unit with Q Series CPU (Use QA conversion adapter)
3.1 Replace A/QnA (Large Type) Series with Q Series
Power supply module (Q Series new) Product name
Power supply module (for extension base unit)
Extension base unit
Input module Output module
*1: Select the module depending on the existing program capacity and contents.
*2: Used to mount the Q Series CPU.
*3: Used to mount modules on the existing main base unit.
*4: Select the cable length according to the arrangement of base units.
Extension base unit (1st stage) Main base unit
CPU module
Existing module Replacement module N/A
A61P (main/extension base unit)
A65B N/A A35B A3ACPU
1
-1
Extension cable
QA conversion adapter module
N/A N/A
Q61P
Utilize existing module
Utilize existing module
Use existing module in original state Use existing module in original state
QA65B*3 Q35B*2 Q03UDCPU*1
QC06B*4 QA6ADP
3 2 1 1
-3
2
-1 1
• The existing A (Large type) Series extension base unit and mounted modules can be utilized without wiring modification.
The existing A (Large Type) Series extension base unit can be used without modifying the wiring by replacing with the extension base QA6B, and remounting the mounted modules.
• Program modifications can be minimized by using the same I/O address for the existing units and setting the current I/O addresses with the parameter I/O assignments.
• The following A (Large Type) Series module cannot be used with the Q Series CPU. These must be changed to a Q Series CPU compatible module.
CC-Link master/local module MELSECNET/10 network module Ethernet module
Ethernet module, computer link module etc.
• The A (Large Type) Series A6B/A5B extension base unit with the QA6ADP cannot be used together with the QA1S6B extension base unit.
• When an AC input module is mounted on the "A5B" extension base unit (without power supply) using the QA6ADP, either the "A6B with QA6ADP" or "QA6B" extension base unit (with power supply) is required in the system.
• Set the stage number for QA6ADP according to the setting of the extension base unit.
• The QA6ADP QA conversion adapter is only compatible with Universal Model QCPU (first five digits of serial No. "13102" or higher).
Process CPUs, Redundant CPUs, Safety CPUs, and Remote I/O Stations are not compatible.
• For the precautions and restrictions when using QA conversion adapter, refer to "QA6ADP QA Conversion Adapter Module User's Manual".
The following is an example of reusing existing A (Large Type) Series modules with a Q Series CPU using the
●
(1) Replace the A (Large Type) Series CPU with the Q Series CPU (Q03UDCPU) and mount it on the Q Series e unit (Q3B).
(Large Type) Series main base unit, mount them on the QA6B extension base unit.
(4) Connect the base units with the Q Series extension cable (QCB).
Replace the A (Large Type)
The adapter allows the A (Large Type) Series extension base unit to be
Q Series modules are mountable
● Module selection example
Tip
3.1 Replace A/QnA (Large Type) Series with Q Series
•By using the current AnS/QnAS (Small Type) module, the wiring work during replacement can be reduced. Replacements can be completed in a short time.
•Replacement is possible even if a compatible L Series module is not available
The CPU can be replaced with the LCPU. An example of using a current A (Small Type) module without modification to shorten the re-wiring man-hours is shown below.
● Instructions
(1) Only the CPU is replaced to the L Series. The current I/O module is used.
Replace the existing AnS/QnAS (Small Type) main base A1S35B to LA1S65B, and mount the existing module.
(2) If the module must be replaced with the L Series, select the module and then mount on the L Series main base unit.
(3) Avoid changing the current I/O assignments.
(1) System configuration example
A1S35B
A1S61PN A2SHCPU A1SX41
X00〜
A1SX41 A1SY41P A1SY41P A1SJ71 E71N
Current configuration After replacement
LA1S65B
A1S61PN A1SX41
X00〜
A1SY41P
A1SX41 A1SY41P
Extension base stage 1 Replace AnS/QnAS (Small Type)
CPU with LCPU
Replace AnS (Small Type) main base with LA1SB,
and mount modules Emp
ty
Empty slot for replacing to L Series module
3.2.1 Utilize AnS/QnAS (Small Type) Series LA1S6B extension base unit