• 検索結果がありません。

Basic Specifications for MCFA Series Rated currents Packaged on tape Your part No. SOC product name Rated current Packaged in a plastic bag Your part

N/A
N/A
Protected

Academic year: 2021

シェア "Basic Specifications for MCFA Series Rated currents Packaged on tape Your part No. SOC product name Rated current Packaged in a plastic bag Your part"

Copied!
17
0
0

読み込み中.... (全文を見る)

全文

(1)

Basic Specifications for MCFA Series

The information in this specification shall be subject to change without notice. March 19, 2015 SOC product name MCFA “Rated current” R08B4

MCFA “Rated current” B

R08B 4: Products packaged on tape B: Products packaged in a plastic bag Certification UL248-1, UL248-14 Listed Rated currents 50 mA–3 A Dimensions and construction

(mm) The structure of this fuse is not hermetically sealed, but resin coating has been applied. Marking SOC “Rated current” Electrical characteristics Certifi- cation Rated voltage Rated breaking current Rated current (IN) Temperature rise Current carrying capacity Overload operation

UL AC 125 V DC 72 V 50 A Resistivecircuit 50 mA–3 A

Not more than 75 K at 1.0 IN 1.0 IN until temperature stabilization occurs. Within 60 s at 2.0 IN Case 2 (Ceramic) 2.4±0.25 1.5±0.15 Metallization Layer

(Nickel plated AgPd)

Case 1 (Ceramic)

1.2±0.15 Termination

(2)

Basic Specifications for MCFA Series

The information in this specification shall be subject to change without notice. March 19, 2015 Rated currents

Packaged on tape Packaged in a plastic bag Your part No. SOC product name Rated

current Your part No. SOC product name

Rated current MCFA 50mAR08B4 50 mA MCFA 50mAB 50 mA MCFA 63mAR08B4 63 mA MCFA 63mAB 63 mA MCFA 80mAR08B4 80 mA MCFA 80mAB 80 mA MCFA 100mAR08B4 100 mA MCFA 100mAB 100 mA MCFA 125mAR08B4 125 mA MCFA 125mAB 125 mA MCFA 160mAR08B4 160 mA MCFA 160mAB 160 mA MCFA 200mAR08B4 200 mA MCFA 200mAB 200 mA MCFA 250mAR08B4 250 mA MCFA 250mAB 250 mA MCFA 315mAR08B4 315 mA MCFA 315mAB 315 mA MCFA 400mAR08B4 400 mA MCFA 400mAB 400 mA MCFA 500mAR08B4 500 mA MCFA 500mAB 500 mA MCFA 630mAR08B4 630 mA MCFA 630mAB 630 mA MCFA 800mAR08B4 800 mA MCFA 800mAB 800 mA

MCFA 1AR08B4 1 A MCFA 1AB 1 A

MCFA 1.25AR08B4 1.25 A MCFA 1.25AB 1.25 A MCFA 1.6AR08B4 1.6 A MCFA 1.6AB 1.6 A

MCFA 2AR08B4 2 A MCFA 2AB 2 A

MCFA 2.5AR08B4 2.5 A MCFA 2.5AB 2.5 A

MCFA 3AR08B4 3 A MCFA 3AB 3 A

Environment-related substances

The six hazardous substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE)) specified in the EU RoHS Directive are not used intentionally in this product, except high melting temperature type solders, containing 85 wt%

or more lead, that are exempted from the Directive. This product conforms to the EU RoHS Directive 2011/65/EU. Lead content as impurities is not more than 0.1 wt%.

(3)

Basic Specifications for MCFA Series

The information in this specification shall be subject to change without notice. March 19, 2015 Mounting

1. Land pattern

(mm) 2. Soldering condition

1) Reflow soldering

Soldering can be repeated 2 times under the conditions above.

・Height of the solder fillets shall be not more than one-third of the overall height (H).

Land pattern and soldering conditions described above are examples when facilities in our company are used. Please make sufficient evaluations under the actual conditions in your company because the conditions may vary depending on facilities, solder type, solder quantity, board size, and board material.

2) Hand soldering with soldering iron

Soldering iron tip temperature: 300 ˚C max. Duration: 2 s or less

Do not touch the terminal directly with a soldering iron.

Do not apply any stress on the fuse body when the body and/or terminal are/is heated. 1/3H H 250 200 150 100 1.5 ˚C/s 60 s–180 s 2 ˚C/s 230 ˚C or more 25 s or less 250 ˚C max. 10 s or less Pre-heating 150 ˚C–160 ˚C Solder jo in t te mpera ture (˚ C) Heating time (s) 1.1 1.5 1.1 1.7

(4)

WARNING: Read and follow these precautions before selecting and using fuses. Failure to properly select, install and use fuses can result in serious injury, death or property damage.

Before final fuse selection, always test the proposed fuse in your actual equipment to ensure that the fuse satisfies all your operational and safety requirements.

Safety Precautions When

Selecting and Using Fuses

Be aware that the breaking ability of a fuse will differ

depending on whether the circuit is an AC or a DC circuit. Fuses intended for use in AC circuits should therefore not be employed in DC circuits, and vice versa, as this may result in accidents such as explosion, property damage, and serious injury.

Use the fuses within the specification requirements. Exceeding specification requirements may result in injury, death or fire.

Shut down the power before touching the fuse. Failure to do so may result in electrocution or serious burns.

Consider the effect of the ambient temperature when you use the fuse.

Electrical performance of the fuse may vary depending on the temperatures.

Do not use the fuse where it is exposed to high humidity, corrosive gas, and flammable gases.

Doing so may result in nuisance operations, disconnection of the fuse-element, or explosion.

Use the fuse in a place where the vibration and impact levels are within the specified limits. Exceeding these limits may result in disconnecting the fuse-element.

Do not form the lead when the fuse is 40 ℃ or more. Lead forming when the fuse is 40 ℃ or more may result in disconnection of the

fuse-element because the load is applied to the fuse-element. Do not apply ultrasonic cleaning to the fuse.

Ultrasonic cleaning may result in disconnection of the

fuse-element.

Use sample fuses only for evaluation.

Do not reuse used fuses. Properly dispose of used fuses. Check if the circuit voltage is

large enough for the fuse operation.

When the circuit voltage is too small, the fuse may not operate even though the abnormal current passes through it, because the current decreases due to the increase of the fuse resistance.

When the fuse is used for a life support system or equipment that requires high reliability, more closely examine and evaluate the fuse in actual circuit conditions than is necessary for other general electronic equipment.

AC

DC

30V

When inserting a fuse into a fuseholder, avoid forcing it. This may result in the fuse cracking or contact failure which will significantly reduce its ability to work properly or shorten its life.

(5)

100μs 1ms 10ms 100ms 1s 0.1A 1A 10A

50 mA

63 mA

80 mA

Pre-arcing time

(ご参考)

FOR REFERENCE ONLY

溶断時間 

Control No.: 050610

Current

This I-t curve is a plot of the average values of the measurement obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values.

Characteristcs of the fuse may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

このI-t特性図は、弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります。参考値であり保証値ではありません。

ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります。

Type: MCFA

I-t Curve

(6)

100μs 1ms 10ms 100ms 1s 0.1A 1A 10A

100 mA

125 mA

160 mA

200 mA

250 mA

315 mA

400 mA

500 mA

630 mA

800 mA

Pre-arcing time

(ご参考)

FOR REFERENCE ONLY

溶断時間 

Control No.: 050610

Current

This I-t curve is a plot of the average values of the measurement obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values.

Characteristcs of the fuse may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

このI-t特性図は、弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります。参考値であり保証値ではありません。 ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります。

SOC Corporation

Type: MCFA

I-t Curve

電流

(7)

100μs 1ms 10ms 100ms 1s 1A 10A 100A

1 A

1.25 A

1.6 A

2 A

2.5 A

3 A

Pre-arcing time

(ご参考)

FOR REFERENCE ONLY

溶断時間 

Control No.: 050610

Current

This I-t curve is a plot of the average values of the measurement obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values.

Characteristcs of the fuse may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

このI-t特性図は、弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります。参考値であり保証値ではありません。

ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります。

Type: MCFA

I-t Curve

(8)

100μs

1ms

10ms

100ms

1s

1E-4A2s 1E-3A2s 0.01A2s 0.1A2s

50 mA

63 mA

80 mA

FOR REFERENCE ONLY

This I2t-t curve is a plot of the average values of the measurement obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values.

Characteristcs of the fuse may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

このI2 t-t特性図は、弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります。参考値であり保証値ではありません。 ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります。

Control No.: 050610

Time I 2 t

Type: MCFA

(ご参考)

I

2

t-t Curve

SOC Corporation

(9)

100μs

1ms

10ms

100ms

1s

1E-3A2s 0.01A2s 0.1A2s 1A2s

100 mA

125 mA

800 mA

630 mA

250 mA

160 mA

200 mA

315 mA

400 mA

500 mA

FOR REFERENCE ONLY

This I2t-t curve is a plot of the average values of the measurement obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values.

Characteristcs of the fuse may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

このI2 t-t特性図は、弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります。参考値であり保証値ではありません。 ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります。

Control No.: 050610

Time I 2 t

Type: MCFA

(ご参考)

I

2

t-t Curve

(10)

100μs

1ms

10ms

100ms

1s

0.01A2s 0.1A2s 1A2s 10A2s

1.6 A

1 A

1.25 A

2 A

2.5 A

3 A

FOR REFERENCE ONLY

This I2t-t curve is a plot of the average values of the measurement obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values.

Characteristcs of the fuse may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

このI2 t-t特性図は、弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります。参考値であり保証値ではありません。 ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります。

Control No.: 050610

Time I 2 t

Type: MCFA

(ご参考)

I

2

t-t Curve

SOC Corporation

(11)

周囲温度の影響-定格電流値のリレーティング

Influence of Ambient Temperature - The Re-rating of the Rated Current

FOR REFERENCE ONLY (ご参考)

Type: MCFA 50mA Control No.:110223

SOC Corporation

Type: MCFA 100mA Control No.: 110223

Type: MCFA 63mA Control No.:110223

Type: MCFA 125mA Control No.:101207

Type: MCFA 80mA Control No.: 110223

Type: MCFA 160mA Control No.:110223

この周囲温度に対する定格電流の変化を示すグラフは、周囲温度-20 ℃、25 ℃及び 85 ℃に於いて弊社が特定した条件で測定した 3 点の実測値であり、お客様での実使用条件を 考慮したものではありません。ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際に ご確認頂く必要があります。

This chart is a plot of the measurements obtained at the ambient temperatures of -20 ˚C, 25 ˚C and 85 ˚C under the conditions specified by SOC;

therefore, conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

(12)

周囲温度の影響-定格電流値のリレーティング

Influence of Ambient Temperature - The Re-rating of the Rated Current

FOR REFERENCE ONLY (ご参考)

Type: MCFA 200mA Control No.:110223

SOC Corporation

Type: MCFA 400mA Control No.: 110223

Type: MCFA 250mA Control No.:110223

Type: MCFA 500mA Control No.:110223

Type: MCFA 315mA Control No.: 110223

Type: MCFA 630mA Control No.:110223

この周囲温度に対する定格電流の変化を示すグラフは、周囲温度-20 ℃、25 ℃及び 85 ℃に於いて弊社が特定した条件で測定した 3 点の実測値であり、お客様での実使用条件を 考慮したものではありません。ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際に ご確認頂く必要があります。

This chart is a plot of the measurements obtained at the ambient temperatures of -20 ˚C, 25 ˚C and 85 ˚C under the conditions specified by SOC;

therefore, conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

(13)

周囲温度の影響-定格電流値のリレーティング

Influence of Ambient Temperature - The Re-rating of the Rated Current

FOR REFERENCE ONLY (ご参考)

Type: MCFA 800mA Control No.:110223

SOC Corporation

Type: MCFA 1.6A Control No.:110223

Type: MCFA 1A Control No.:110223

Type: MCFA 2A Control No.:110223

Type: MCFA 1.25A Control No.: 110223

Type: MCFA 2.5A Control No.:110223

この周囲温度に対する定格電流の変化を示すグラフは、周囲温度-20 ℃、25 ℃及び 85 ℃に於いて弊社が特定した条件で測定した 3 点の実測値であり、お客様での実使用条件を 考慮したものではありません。ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際に ご確認頂く必要があります。

This chart is a plot of the measurements obtained at the ambient temperatures of -20 ˚C, 25 ˚C and 85 ˚C under the conditions specified by SOC;

therefore, conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

(14)

FOR REFERENCE ONLY

(ご参考)

Type: MCFA 3A

Control No.: 110223

SOC Corporation

周囲温度の影響-定格電流値のリレーティング

Influence of Ambient Temperature - The Re-rating of the Rated Current

この周囲温度に対する定格電流の変化を示すグラフは、周囲温度-20 ℃、25 ℃及び 85 ℃に於いて弊社が特定した条件で測定した 3 点の実測値であり、お客様での実使用条件を 考慮したものではありません。ヒューズの特性はその使用条件により変化しますので、お客様にヒューズのご使用条件下で、ヒューズがお客様のご要求を満足しているかを実際に ご確認頂く必要があります。

This chart is a plot of the measurements obtained at the ambient temperatures of -20 ˚C, 25 ˚C and 85 ˚C under the conditions specified by SOC;

therefore, conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse in the circuit under the actual circuit conditions.

(15)

Technical Specifications for MCFA Series

March 19, 2015 1. Construction

No. Part Name Materials and finish

① Case Ceramic

② Fuse-element ―

③ Solder Sn-8.0Ag-2.0Pb

④ Adhesive Epoxy resin

⑤ Terminal Nickel plated AgPd ⑥ Sealant Silicon resin

(UL flame retardancy grade UL746C/94V-0) 2. Usage conditions

Ambient temperature: -20 ˚C–+85 ˚C Note: Current carrying capacity of the fuse may vary depending on the ambient temperature.

Ambient humidity: 85% RH or less 3. Storage conditions and storage period

Products packaged as delivered can be stored for 1 year from our shipment. Ambient temperature: -20 ˚C–+40 ˚C (No condensation)

Ambient humidity: 85% RH or less

Ambient atmosphere: - Not exposed to corrosive gas or sea breeze. - No visible dust.

- Not exposed to direct sunlight.

Load: No application of load that may cause deformation or degradation of the product. 4. Typical cold resistance (for reference only)

Rated current Typical cold resistance Rated current Typical cold resistance Rated current Typical cold resistance 50 mA 3600 mΩ 250 mA 470 mΩ 1.25 A 95 mΩ 63 mA 3000 mΩ 315 mA 280 mΩ 1.6 A 70 mΩ 80 mA 1700 mΩ 400 mA 200 mΩ 2 A 50 mΩ 100 mA 1450 mΩ 500 mA 190 mΩ 2.5 A 38 mΩ 125 mA 1000 mΩ 630 mA 185 mΩ 3 A 30 mΩ 160 mA 650 mΩ 800 mA 150 mΩ 200 mA 615 mΩ 1 A 105 mΩ ③ ④ ② ① ⑥

(16)

Packaging Specifications for MCFA R08B4

March 19, 2015 1.Packaging

1.1 Tape configuration

This product shall be packaged as per Type II-Blister carrier tape with single sprocket holes (the width of the tape is 8 mm) stipulated in JIS C 0806-3 Packaging of components for

automatic handling Part 3: Packaging of surface mount components on continuous tapes (see Figure 1).

Figure 1 (mm)

Sectional view A-A’

Sec

tional v

(17)

Packaging Specifications for MCFA R08B4

March 19, 2015 1.2 Reel configuration

The reel used for packaging this product is mostly in accordance with JIS C 0806-3 Packaging of components for automatic handling-Part 3: Packaging of surface

mount components on continuous tapes (see Figure 2).

Figure 2 (mm)

1.3 Packing quantity

The packaging code consists of a symbol “R08B” representing a reel configuration and a mounting hole pitch “4” added as a suffix. Quantity to be packed is as in the table below.

Packaging code Quantity R08B4 2,000 pcs. 1.4 Contents of marking

The following information shall be indicated on one side of the reel. ・Your part number (by request)

・Lot No. ・Quantity of fuses ・Packaged date ・Packaging code ・Country of origin ・Manufacturer ・Production facilities

・Indications specified by the applicable standards 2.Lot number

The lot number indicates the following:

Example: 1 5 0 1 2 3 7 1 Date manufactured Process code (January 23, 2015) φ13 ± 0.2 φ180 -30 9 ± 0.3 11.4 ± 1.0 φ60 +1 0

参照

関連したドキュメント

品名(Part name) 数量(Quantity).. 品名(Part name) 数量(Quantity).. 品名(Part name) 数量(Quantity).. 部品番号 (Part No.) 品名(Part name)

Tschinkel, Height zeta functions of toric bundles over flag varieties, Selecta Math. Tate, Fourier analysis in number fields, and Hecke’s zeta-functions, 1967 Algebraic Number

So, our result is the first example of an algebraic family of rational maps (which are neither totally ramified at infinity, nor Latt´ es maps, and also admit bad fibers) for which

The unpublished data used in the economical evaluation corresponded to the diameter at breast height of 10 m height mature gray birch trees collected in 2004, which are part of

Taking as the connected component of the subgraph in the Baby Monster graph induced on the set of vertices fixed by an element of order 3 and in view of (1.5)(iv) one gets the

Apart from the fact that a contractible simple closed curve bounds a disc we mention the following (cf. [7]): “between” freely homotopic essential simple closed curves with

The various structure results used above together imply that if G is an almost connected group, then G contains a closed amenable subgroup H such that G/H with the quotient topology

Thus, although in many concrete cases of approximation schemes (X, {A n }) there ex- ist some results, such as the representation theorems or the characterizations in terms of moduli