2
2
Before Connection > Items to Prepare in Advance
Before Connection > Items to Prepare in Advance
How to Check this Installation Procedure
When Using the Parts Included in the Package
A symbol is described on the illustration in the case of using the parts included in the package of this product.
Packaged Item
Smbols in the Illustration
The frequently-performed operations are described with symbols in this procedure. Connector
Disconnect Screw
Tighten Remove Connect Secure Free Harness
Push
Insert Plug in Turn on
Sound Check Check Visual Check
Claw Remove Checking instruction F-1-1 F-1-2
Before Connection
The IP addresses for communication between the host
machine and server are set automatically
1) Enter the Service Mode (level 1).
2) Select COPIER > OPTION > INT-FACE > IMG-CONT > "3". 3) Exit the Service Mode.
Securing space for installation
Secure a space to install this equipment as shown in the figure below. A space of 200 mm or more is required from the back of this equipment.
Rear 200mm+ (8 in.) 200mm+ (8 in.) PS Unit Front
<
Top view>
Items to Prepare in Advance
• Mouse• Monitor • Keyboard
3
3
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB
Checking the Contents
[1] PS Unit X 1 [2] Open I/F PCB X 1 [3] Interface Cable X 1
[4] Power Cord [5] Cross Ethernet
Cable 3.0m X1 [6] Shield Ethernet Cable 3.0m X1
Europe x 2
USA x 1
[4] Power Cord: The connector has a different shape depending on locations. Use the correct power code to mach the location/area of installation. Make sure not to leave unused power code at the site.
< CD/Guides > • Media Pack
Check Items when Turning OFF the Main Power
Check that the main power switch is OFF.
1) Turn OFF the main power switch of the host machine.
2) Be sure that display in the Control Panel and the lamp of the main power supply are turned off, then disconnect the power plug.
F-1-4
Installation Procedure
In the case iR-ADV C5255/C5250/C5240/C5235 Series
■ Installing the Open I/F PCB
1) Remove the Left Rear Cover. • 2 Rubber Caps • 2 Screws • 5 Claws
x2
x5
Claws Rubber Caps Rubber Caps F-1-54
4
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB
2) When the Reader is installed, remove the Reader Communication Cable.
3) Remove the Left Rear Sub Cover. • 1 Screw • 1 Hook Hook Left Rear Sub Cover F-1-6 F-1-7
4) When the FAX is installed, remove the FAX cable.
5) Hold the handle to remove Main Controller PCB 2. • 2 Screws
x2
Grip
F-1-8
5
5
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB
6) Remove the Face Cover. (Removed Face Cover is not used.) • 2 Screws (the removed screws are used in step 9))
NOTE:
Ask the user to store the Face Cover, in case it is needed in the future.
x2
7) Remove the 2 screws. (the removed screws are used in step 9))
x2
F-1-10
F-1-11
8) Remove the Bypass PCB (the removed Bypass PCB is not used). • 2 Screws (the removed screws are used in step 9))
NOTE:
Ask the user to store the Bypass PCB, in case it is needed in the future.
x2
9) Install the Open I/F PCB. • 1 Connector
• 6 Screws (the screws removed in step 6), 7) and 8))
x4
x2
F-1-12
6
6
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit
10) Install Main Controller PCB 2. CAUTION:
• Lift the grip and insert the Main Controller PCB 2. When it touches the end, tilt the grip and install it with 2 screws.
• Make sure to tilt the grip slowly on both sides simultaneously. • Check that the Main Controller PCB 2 is installed properly.
x2
Grip
11) Install the FAX Cable (if the FAX is installed). 12) Install the Left Rear Sub Cover. (1 Screw)
13) Install the Reader Communication Cable (if the Reader is installed).
14) Connect the Interface Cable to the installed Open I/F PCB.
F-1-14
F-1-15
15) Cut off [A] part of the Left Rear Cover with nippers. CAUTION:
Be sure to remove adequately so that there is no burr.
[A]
16) Install the Left Reader Cover. (2 Screws, 2 Rubber Caps)
■ Installing the PS Unit
1) Install the PS Unit to the left side of the host machine. F-1-16
7
7
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit
Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit
2) Connect the Interface Cable to the PS Unit.
3) Open the Right Rear Cover 1 to install the Cross Ethernet Cable. • 1 Wire Saddle
Wire Saddle F-1-18
F-1-19
4) Close the Right Rear Cover 1.
5) Connect the Power Cord and the Shield Ethernet Cable to the PS Unit. CAUTION:
• Use the correct power code to mach the location/area of installation. Make sure not to leave unused power code at the site.
• Be sure to use the network cable with Category 5e or higher. In addition, a sealed type (STP cable) is recommended. When using the non-sealed type (UTP cable), it may influence the surrounding electronic equipments via network cable.
x2
Power Cord
Shield Ethernet Cable
6) Plug the power cord into an outlet.
7) Turn the PS Unit power on, then turn the host machine power switch on.
8) When the message "Turn the host machine power off and back on" appears on the touch panel, turn the host machine power switch off.
NOTE:
On PS Unit, it automatically restarts only at the first time connection. It takes approx. 5 minutes until it is ready for use.
Do not press the buttons on the PS Unit until it is ready for use. 9) Turn the host machine power switch on again.
8
8
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB
In the case iR-ADV C9280 PRO/C9270 PRO Series,
iR-ADV C7280/C7270/C7260 Series
■ Installing the Open I/F PCB
1) Remove the Box Left Cover.• 2 Screws (the removed screws are used in step 12.)
x2
2) Disconnect the Reader Communication Cable and release the 2 Lock Levers.
Lock Lever
Reader Communication Cable F-1-21
F-1-22
3) Hold the grip to remove Main Controller PCB 2. • 2 screws (the removed screws are used in step 9.)
Grip
x2
4) Remove the Face Cover. (Removed Face Cover is not used.) • 2 Screws (the removed screws are used in step 7).)
NOTE:
Ask the user to store the Face Cover and Screws, in case it is needed in the future.
x2
F-1-23
9
9
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB
5) Remove the 2 screws. (the removed screws are used in step 7).)
x2
6) Remove the Bypass PCB. (Removed Bypass PCB is not used.) • 2 Screws (the removed screws are used in step 7).)
• 1 Connector NOTE:
Ask the user to store the Bypass PCB and Screws, in case it is needed in the future.
x2
Connector
F-1-25
F-1-26
7) Install the Open I/F PCB. • 1 Connector
• 6 Screws (the screws removed in step 4), 5) and 6).)
x2
x4
Connector
8) Release the 2 Lock Levers in the direction of the arrow and push the Main Controller PCB 2 with both hands until it stops.
CAUTION:
Be careful not to make the cables caught and install the Main Controller 2.
Lock Lever
F-1-27
10
10
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB
9) Turn over the 2 Lock Levers, push the Main Controller PCB 2 in and fix it.
• 2 Screws (screw removed in step 3): Install the upper one first and then the lower one.) CAUTION:
Reliable work in order from Figure 1 to 4 should be done in case of no connection regarding Main Controller PCB 2.
Lock Lever
x2
10) Disconnect the Reader Communication Cable.
F-1-29
11) Connect the Interface Cable to the Open I/F PCB.
CAUTION:
Do not connect to the connector of FAX.
F-1-31 F-1-30
11
11
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit
■ Installing the PS Unit
1) Install the PS Unit to the left side of the host machine.
2) Connect the Interface Cable to the PS Unit.
F-1-32
F-1-33
3) Open the HDD Cover, connect one end of the Crossover Ethernet Cable to the host machine and then connect another end to the PS Unit.
Cross Ethernet Cable
4) Close the HDD Cover.
12
12
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit
Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit
5) Connect the Power Cord and the Shield Ethernet Cable to the PS Unit. CAUTION:
• Use the correct power code to mach the location/area of installation. Make sure not to leave unused power code at the site.
• Be sure to use the network cable with Category 5e or higher. In addition, a sealed type (STP cable) is recommended. When using the non-sealed type (UTP cable), it may influence the surrounding electronic equipments via network cable.
x2
Power Cord
Shield Ethernet Cable
F-1-35
6) Plug the power cord into an outlet.
7) Turn the PS Unit power on, then turn the host machine power switch on.
8) When the message "Turn the host machine power off and back on" appears on the touch panel, turn the host machine power switch off.
NOTE:
On PS Unit, it automatically restarts only at the first time connection. It takes approx. 5 minutes until it is ready for use.
Do not press the buttons on the PS Unit until it is ready for use. 9) Turn the host machine power switch on again.
13
13
Settings after Installation
Settings after Installation
Settings after Installation
1) At the Main menu, press [Printer].
2) Press [Printer Status/Settings].
3) At the Languages Setup screen, select the name of the language you want to use, and then select OK.
Wait a few minutes.
F-1-36
F-1-37
Input of password:
When setting it up, the password input screen is displayed. Entering "Fiery.1" in the password field displays the setting screen.
NOTE:
Use single-byte upper case to enter F of "Fiery.1". Use single-byte lower case to enter other characters.
In response, the machine will automatically show the Settings menu. Be sure to at least select the following and make the appropriate settings in the indicated order: [Server Setup], [Network Setup], and [Printer Setup].
For more information, see "Settings Management" on the User Manual.
For instance, once you have made the various settings under [Server Setup], you will be shown a screen asking you if you want to store the settings. Select [yes] so that the system will be stored in memory. Unless you have made appropriate settings in the correct order and saved them, you will not be able to go on to the next item.
14
14
Settings after Installation
Settings after Installation Making Server Settings:
Make the appropriate settings including the name of the server.
Making Network Settings:
Make the appropriate settings including Port Setup, Protocol Setup, and Service Setup. F-1-39
F-1-40
Making Printer Settings:
Make the appropriate settings including print queue.
4) Select [close] on the Settings menu. In response, the system will restart automatically. F-1-41
15
15
Settings after Installation > Checking the Operation After Making the Settings
Settings after Installation > Checking the Operation After Making the Settings
Checking the Operation After Making the Settings
Print out a test page and a settings page as follows to make sure that all settings have correctly been made on the equipment and its host machine and that all connections are normal:1) At the Main menu, press [Printer].
2) Press [Print Server Status/Settings].
F-1-42
F-1-43
3) Make the following selections on the control panel : [Functions] > [Print page] > [Test Page] and [Configuration].
F-1-44
16
16
Settings after Installation > Executing Auto Gradation Adjustment
Settings after Installation > Executing Auto Gradation Adjustment
Connecting to the Network
Ask the network administrator to connect to the network, make settings and output the test print.
Refer to "Settings Management" in User Manual for details of checking work.
Executing Auto Gradation Adjustment
After installation, execute Auto Gradation Adjustment on the host machine.
• If the Color Image Reader is installed in the host machine, perform Auto Gradation Adjustment (Full Adjust) with Plain Paper, Heavy 1/Heavy 2 and Heavy 3/Heavy 4. • If the Color Image Reader does not exist in the host machine, execute: [Settings/
Registration] > [Adjustment/Maintenance] > [Adjust Image Quality] > [Auto Adjust Gradation].
17
17
本設置手順書の見方について
注意 : 以下は日本モデル用の設置手順が記載されている。 日本モデル以外の設置手順は、 英文設置手順に従うこと。同梱部品を使用する場合
本製品に同梱されている部品を使用する場合は、 イラスト内に同梱部品使用のシンボルを記 載してある。同梱部品
イラスト内のシンボルマークについて
本手順書では、 よく行う動作などについてシンボルマークで表現している。 コネクタ 取付け ビス 取付け 取外し 取外し 取付け 取外し 束線 押す 取外し コンセント 差込み スイッチON 音確認 確認 目視 爪 取付け F-1-1 F-1-2接続前の準備
本体と本機間の通信用 IP アドレスを自動で設定する
1) サービスモード ( レベル 1) に入る。2) COPIER > OPTION > INT-FACE > IMG-CONT > "3" を選択する。 3) サービスモードから抜ける。