• 検索結果がありません。

Before Connection > Items to Prepare in Advance How to Check this Installation Procedure Before Connection 2 When Using the Parts Included in the Pack

N/A
N/A
Protected

Academic year: 2021

シェア "Before Connection > Items to Prepare in Advance How to Check this Installation Procedure Before Connection 2 When Using the Parts Included in the Pack"

Copied!
28
0
0

読み込み中.... (全文を見る)

全文

(1)

ENGLISH

日本語

ColorPASS-GX400 Installation Procedure

ColorPASS-GX400 設置手順書

This installation procedure is written in Japanese and English. The installation procedure for Japan model is described in Japanese and one for the other models is

described in English. These procedures are different from each other. Follow the procedure corresponding to the installed model.

- Japanese: The installation procedure for Japan model

- English: The installation procedure for the other models except for Japan model

この設置手順書には、和文と英文の設置手順が記載されている。和文では日本モデル用の設置手順が記載されており、英文では日本モデル以外のその他のモデル用の設

置手順が記載されている。それぞれの設置手順は異なっているので、モデルに応じた手順に従うこと。

・和文: 日本モデル用設置手順

・英文: 日本モデル以外のその他のモデル用設置手順

(2)

2

2

Before Connection > Items to Prepare in Advance

Before Connection > Items to Prepare in Advance

How to Check this Installation Procedure

When Using the Parts Included in the Package

A symbol is described on the illustration in the case of using the parts included in the package of this product.

Packaged Item

Smbols in the Illustration

The frequently-performed operations are described with symbols in this procedure. Connector

Disconnect Screw

Tighten Remove Connect Secure Free Harness

Push

Insert Plug in Turn on

Sound Check Check Visual Check

Claw Remove Checking instruction F-1-1 F-1-2

Before Connection

The IP addresses for communication between the host

machine and server are set automatically

1) Enter the Service Mode (level 1).

2) Select COPIER > OPTION > INT-FACE > IMG-CONT > "3". 3) Exit the Service Mode.

Securing space for installation

Secure a space to install this equipment as shown in the figure below. A space of 200 mm or more is required from the back of this equipment.

Rear 200mm+ (8 in.) 200mm+ (8 in.) PS Unit Front

Top view>

Items to Prepare in Advance

• Mouse

• Monitor • Keyboard

(3)

3

3

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB

Checking the Contents

[1] PS Unit X 1 [2] Open I/F PCB X 1 [3] Interface Cable X 1

[4] Power Cord [5] Cross Ethernet

Cable 3.0m X1 [6] Shield Ethernet Cable 3.0m X1

Europe x 2

USA x 1

[4] Power Cord: The connector has a different shape depending on locations. Use the correct power code to mach the location/area of installation. Make sure not to leave unused power code at the site.

< CD/Guides > • Media Pack

Check Items when Turning OFF the Main Power

Check that the main power switch is OFF.

1) Turn OFF the main power switch of the host machine.

2) Be sure that display in the Control Panel and the lamp of the main power supply are turned off, then disconnect the power plug.

F-1-4

Installation Procedure

In the case iR-ADV C5255/C5250/C5240/C5235 Series

■ Installing the Open I/F PCB

1) Remove the Left Rear Cover. • 2 Rubber Caps • 2 Screws • 5 Claws

x2

x5

Claws Rubber Caps Rubber Caps F-1-5

(4)

4

4

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB

2) When the Reader is installed, remove the Reader Communication Cable.

3) Remove the Left Rear Sub Cover. • 1 Screw • 1 Hook Hook Left Rear Sub Cover F-1-6 F-1-7

4) When the FAX is installed, remove the FAX cable.

5) Hold the handle to remove Main Controller PCB 2. • 2 Screws

x2

Grip

F-1-8

(5)

5

5

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the Open I/F PCB

6) Remove the Face Cover. (Removed Face Cover is not used.) • 2 Screws (the removed screws are used in step 9))

NOTE:

Ask the user to store the Face Cover, in case it is needed in the future.

x2

7) Remove the 2 screws. (the removed screws are used in step 9))

x2

F-1-10

F-1-11

8) Remove the Bypass PCB (the removed Bypass PCB is not used). • 2 Screws (the removed screws are used in step 9))

NOTE:

Ask the user to store the Bypass PCB, in case it is needed in the future.

x2

9) Install the Open I/F PCB. • 1 Connector

• 6 Screws (the screws removed in step 6), 7) and 8))

x4

x2

F-1-12

(6)

6

6

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit

10) Install Main Controller PCB 2. CAUTION:

• Lift the grip and insert the Main Controller PCB 2. When it touches the end, tilt the grip and install it with 2 screws.

• Make sure to tilt the grip slowly on both sides simultaneously. • Check that the Main Controller PCB 2 is installed properly.

x2

Grip

11) Install the FAX Cable (if the FAX is installed). 12) Install the Left Rear Sub Cover. (1 Screw)

13) Install the Reader Communication Cable (if the Reader is installed).

14) Connect the Interface Cable to the installed Open I/F PCB.

F-1-14

F-1-15

15) Cut off [A] part of the Left Rear Cover with nippers. CAUTION:

Be sure to remove adequately so that there is no burr.

[A]

16) Install the Left Reader Cover. (2 Screws, 2 Rubber Caps)

■ Installing the PS Unit

1) Install the PS Unit to the left side of the host machine. F-1-16

(7)

7

7

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit

Installation Procedure > In the case iR-ADV C5255/C5250/C5240/C5235 Series > Installing the PS Unit

2) Connect the Interface Cable to the PS Unit.

3) Open the Right Rear Cover 1 to install the Cross Ethernet Cable. • 1 Wire Saddle

Wire Saddle F-1-18

F-1-19

4) Close the Right Rear Cover 1.

5) Connect the Power Cord and the Shield Ethernet Cable to the PS Unit. CAUTION:

• Use the correct power code to mach the location/area of installation. Make sure not to leave unused power code at the site.

• Be sure to use the network cable with Category 5e or higher. In addition, a sealed type (STP cable) is recommended. When using the non-sealed type (UTP cable), it may influence the surrounding electronic equipments via network cable.

x2

Power Cord

Shield Ethernet Cable

6) Plug the power cord into an outlet.

7) Turn the PS Unit power on, then turn the host machine power switch on.

8) When the message "Turn the host machine power off and back on" appears on the touch panel, turn the host machine power switch off.

NOTE:

On PS Unit, it automatically restarts only at the first time connection. It takes approx. 5 minutes until it is ready for use.

Do not press the buttons on the PS Unit until it is ready for use. 9) Turn the host machine power switch on again.

(8)

8

8

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB

In the case iR-ADV C9280 PRO/C9270 PRO Series,

iR-ADV C7280/C7270/C7260 Series

■ Installing the Open I/F PCB

1) Remove the Box Left Cover.

• 2 Screws (the removed screws are used in step 12.)

x2

2) Disconnect the Reader Communication Cable and release the 2 Lock Levers.

Lock Lever

Reader Communication Cable F-1-21

F-1-22

3) Hold the grip to remove Main Controller PCB 2. • 2 screws (the removed screws are used in step 9.)

Grip

x2

4) Remove the Face Cover. (Removed Face Cover is not used.) • 2 Screws (the removed screws are used in step 7).)

NOTE:

Ask the user to store the Face Cover and Screws, in case it is needed in the future.

x2

F-1-23

(9)

9

9

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB

5) Remove the 2 screws. (the removed screws are used in step 7).)

x2

6) Remove the Bypass PCB. (Removed Bypass PCB is not used.) • 2 Screws (the removed screws are used in step 7).)

• 1 Connector NOTE:

Ask the user to store the Bypass PCB and Screws, in case it is needed in the future.

x2

Connector

F-1-25

F-1-26

7) Install the Open I/F PCB. • 1 Connector

• 6 Screws (the screws removed in step 4), 5) and 6).)

x2

x4

Connector

8) Release the 2 Lock Levers in the direction of the arrow and push the Main Controller PCB 2 with both hands until it stops.

CAUTION:

Be careful not to make the cables caught and install the Main Controller 2.

Lock Lever

F-1-27

(10)

10

10

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the Open I/F PCB

9) Turn over the 2 Lock Levers, push the Main Controller PCB 2 in and fix it.

• 2 Screws (screw removed in step 3): Install the upper one first and then the lower one.) CAUTION:

Reliable work in order from Figure 1 to 4 should be done in case of no connection regarding Main Controller PCB 2.

Lock Lever

x2

10) Disconnect the Reader Communication Cable.

F-1-29

11) Connect the Interface Cable to the Open I/F PCB.

CAUTION:

Do not connect to the connector of FAX.

F-1-31 F-1-30

(11)

11

11

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit

■ Installing the PS Unit

1) Install the PS Unit to the left side of the host machine.

2) Connect the Interface Cable to the PS Unit.

F-1-32

F-1-33

3) Open the HDD Cover, connect one end of the Crossover Ethernet Cable to the host machine and then connect another end to the PS Unit.

Cross Ethernet Cable

4) Close the HDD Cover.

(12)

12

12

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit

Installation Procedure > In the case iR-ADV C9280 PRO/C9270 PRO Series, iR-ADV C7280/C7270/C7260 Series > Installing the PS Unit

5) Connect the Power Cord and the Shield Ethernet Cable to the PS Unit. CAUTION:

• Use the correct power code to mach the location/area of installation. Make sure not to leave unused power code at the site.

• Be sure to use the network cable with Category 5e or higher. In addition, a sealed type (STP cable) is recommended. When using the non-sealed type (UTP cable), it may influence the surrounding electronic equipments via network cable.

x2

Power Cord

Shield Ethernet Cable

F-1-35

6) Plug the power cord into an outlet.

7) Turn the PS Unit power on, then turn the host machine power switch on.

8) When the message "Turn the host machine power off and back on" appears on the touch panel, turn the host machine power switch off.

NOTE:

On PS Unit, it automatically restarts only at the first time connection. It takes approx. 5 minutes until it is ready for use.

Do not press the buttons on the PS Unit until it is ready for use. 9) Turn the host machine power switch on again.

(13)

13

13

Settings after Installation

Settings after Installation

Settings after Installation

1) At the Main menu, press [Printer].

2) Press [Printer Status/Settings].

3) At the Languages Setup screen, select the name of the language you want to use, and then select OK.

Wait a few minutes.

F-1-36

F-1-37

Input of password:

When setting it up, the password input screen is displayed. Entering "Fiery.1" in the password field displays the setting screen.

NOTE:

Use single-byte upper case to enter F of "Fiery.1". Use single-byte lower case to enter other characters.

In response, the machine will automatically show the Settings menu. Be sure to at least select the following and make the appropriate settings in the indicated order: [Server Setup], [Network Setup], and [Printer Setup].

For more information, see "Settings Management" on the User Manual.

For instance, once you have made the various settings under [Server Setup], you will be shown a screen asking you if you want to store the settings. Select [yes] so that the system will be stored in memory. Unless you have made appropriate settings in the correct order and saved them, you will not be able to go on to the next item.

(14)

14

14

Settings after Installation

Settings after Installation Making Server Settings:

Make the appropriate settings including the name of the server.

Making Network Settings:

Make the appropriate settings including Port Setup, Protocol Setup, and Service Setup. F-1-39

F-1-40

Making Printer Settings:

Make the appropriate settings including print queue.

4) Select [close] on the Settings menu. In response, the system will restart automatically. F-1-41

(15)

15

15

Settings after Installation > Checking the Operation After Making the Settings

Settings after Installation > Checking the Operation After Making the Settings

Checking the Operation After Making the Settings

Print out a test page and a settings page as follows to make sure that all settings have correctly been made on the equipment and its host machine and that all connections are normal:

1) At the Main menu, press [Printer].

2) Press [Print Server Status/Settings].

F-1-42

F-1-43

3) Make the following selections on the control panel : [Functions] > [Print page] > [Test Page] and [Configuration].

F-1-44

(16)

16

16

Settings after Installation > Executing Auto Gradation Adjustment

Settings after Installation > Executing Auto Gradation Adjustment

Connecting to the Network

Ask the network administrator to connect to the network, make settings and output the test print.

Refer to "Settings Management" in User Manual for details of checking work.

Executing Auto Gradation Adjustment

After installation, execute Auto Gradation Adjustment on the host machine.

• If the Color Image Reader is installed in the host machine, perform Auto Gradation Adjustment (Full Adjust) with Plain Paper, Heavy 1/Heavy 2 and Heavy 3/Heavy 4. • If the Color Image Reader does not exist in the host machine, execute: [Settings/

Registration] > [Adjustment/Maintenance] > [Adjust Image Quality] > [Auto Adjust Gradation].

(17)

17

17

本設置手順書の見方について

注意 : 以下は日本モデル用の設置手順が記載されている。 日本モデル以外の設置手順は、 英文設置手順に従うこと。

同梱部品を使用する場合

本製品に同梱されている部品を使用する場合は、 イラスト内に同梱部品使用のシンボルを記 載してある。

同梱部品

イラスト内のシンボルマークについて

本手順書では、 よく行う動作などについてシンボルマークで表現している。 コネクタ 取付け ビス 取付け 取外し 取外し 取付け 取外し 束線 押す 取外し コンセント 差込み スイッチON 音確認 確認 目視 爪 取付け F-1-1 F-1-2

接続前の準備

本体と本機間の通信用 IP アドレスを自動で設定する

1) サービスモード ( レベル 1) に入る。

2) COPIER > OPTION > INT-FACE > IMG-CONT > "3" を選択する。 3) サービスモードから抜ける。

設置するスペースを確保する

図のように本機を設置するスペースを確保する。 本機の背面から 200 mm 以上のスペースが 必要である。 背面 200mm+ (8 in.) 200mm+ (8 in.) PSユニット 前面

<Top view>

事前に準備するもの

・ マウス ・ モニター ・ キーボード F-1-3

(18)

18

18

同梱部品の確認

[1] PSユニット X 1 [2] オープンI/F基板 X 1 [3] インターフェース ケーブル X 1 [4] 電源コード [5] クロスイーサネット ケーブル 3.0m X1 [6] シールドイーサネットケーブル 3.0m X1 < CD/ ガイド類 > ・ メディアパック

本体主電源 OFF の確認事項

本体の主電源が OFF であることを確認する。 1) 本体の主電源スイッチを OFF する。 2) 操作パネルの表示と主電源ランプが消えたことを確認してから電源プラグを外す。 F-1-4

設置手順

iR-ADV C9280 PRO/C9270 PRO シリーズ ,

iR-ADV C7280/C7270/C7260 シリーズ

■ オープン I/F 基板の取付け

1) ボックス左カバーを外す。 ・ ビス 2 本 ( 外したビスは手順 12) で使用する )

x2

2) リーダー通信ケーブルを外し、 ロックレバー 2 箇所を解除する。 ロックレバー リーダー通信ケーブル F-1-5 F-1-6

(19)

19

19

3) 取っ手を持ち、 メインコントローラー基板 2 を外す。 ・ ビス 2 本 ( 外したビスは手順 9) で使用する ) 取っ手

x2

4) 目隠し板を外す ( 外した目隠し板は使用しない )。 ・ ビス 2 本 ( 外したビスは手順 7) で使用する ) メモ : 外した目隠し板はユーザーに渡し、 保管して頂くこと。

x2

F-1-7 5) ビス 2 本を外す ( 外したビスは手順 7) で使用する )。

x2

6) バイパス基板を外す ( 外したバイパス基板は使用しない )。 ・ ビス 2 本 ( 外したビスは手順 7) で使用する ) ・ コネクタ 1 箇所 メモ : 外したバイパス基板はユーザーに渡し、 保管して頂くこと。

x2

コネクタ F-1-8 F-1-9

(20)

20

20

7) オープン I/F 基板を取付ける。 ・ コネクタ 1 箇所 ・ ビス 6 本 ( 手順 4)、 5)、 6) で外したビスを使用する )

x2

x4

コネクタ 8) ロックレバー 2 箇所を矢印の方向に解除し、 メインコントローラー基板 2 を突き当たるまで 両手で均等に押込む。 注意 : ケーブル類をはさみこまないように注意して、 メインコントローラー基板 2 を取付ける。 ロック レバー F-1-10 F-1-11 9) ロックレバー 2 個を倒して、 さらにメインコントローラー基板 2 を押込み、 固定する。 ・ ビス 2 本 ( 手順 3) で外したビス : 下、 上の順に取付ける ) 注意 : メインコントローラー基板 2 のコネクタが接続されていない場合があるため、 図の 1 ~ 4 の順番で確実に作業を行うこと。 ロック レバー

x2

10) リーダー通信ケーブルを接続する。 F-1-12

(21)

21

21

11) オープン I/F 基板にインターフェースケーブルを接続する。 注意 : FAX のコネクタには接続しないこと。 F-1-14 F-1-13 12) インターフェースケーブルをボックス左カバーの穴に通して、 ボックス左カバーを取付ける。 ・ ビス 2 本 ( 手順 1) で外したビスを使用する)

x2

穴 F-1-15

(22)

22

22

■ PS ユニットの設置

1) PS ユニットを本体左側に設置する。 2) PS ユニットにインターフェースケーブルを取付ける。 F-1-16 F-1-17 3) HDD カバーを開き、 クロスイーサネットケーブルを本体と PS ユニットに接続する。 クロスイーサネットケーブル 4) HDD カバーを閉める。 F-1-18

(23)

23

23

5) 電源コードとシールドイーサネットケーブルを PS ユニットに接続する。 注意 : ネットワークケーブルは、 カテゴリー 5e 以上のランクのものを使用すること。 また、シールドタイプ (STP ケーブル ) の使用を推奨する。 ノンシールドタイプ (UTP ケー ブル ) を使用すると、 ネットワークケーブルを経由して、 周りの電子機器に影響を及ぼ す可能性がある。

x2

電源コード シールドイーサネットケーブル F-1-19 6) 電源プラグをコンセントに差込む。 7) PS ユニットの電源を ON した後、 本体の主電源スイッチを ON する。 8) タッチパネル上に " 本体の主電源を入れ直してください " と表示したら、 本体の主電源ス イッチを OFF する。 メモ : PS ユニットは、 接続した初回だけ自動的に再起動する。 使用可能になるまで約 5 分かかる。 使用可能になるまで、 PS ユニットのボタンを押さないこと。 9) 再び、 本体の主電源スイッチを ON する。

(24)

24

24

設置後の設定

1) 本体の液晶表示部上のメインメニューから [ プリントサーバー ] を選択する。 2) [ プリントサーバーの状況 / 設定 ] ボタンを押す。 F-1-20 F-1-21

パスワードの入力 :

設置時にパスワード入力画面が表示される。 パスワード欄に 「Fiery.1」 を入力すると設定画面が表示される。 メモ : Fiery.1 の F は半角大文字で入力する。 それ以外は半角小文字で入力する。 その後、自動的に 「設定」 メニューに入るので最低 「サーバ設定」、 「ネットワーク設定」、 「プリンタ設定」 の各項目を順番に選択し、 各々データを保存する。 詳細は、 取扱説明書の 「設定管理」 を参照する。 例えば、 「サーバ設定」 の各項目を設定していくと、 最後に変更の保存をするかどうかを 選択する画面が表示されるので、 「はい」 を選択すると、 その時の設定を保存することが できる。 各項目を順番に選択して保存しないと次の項目を設定できない。 F-1-22

(25)

25

25

サーバー設定 :

サーバー名の設定等を行う。

ネットワーク設定 :

ポート設定、 プロトコル設定、 サービス設定を行う。 F-1-23 F-1-24

プリンタ設定 :

印刷キューの設定を行う。 3) 「設定」 メニューの 「閉じる」 を選択する。 その後、 自動的に再起動が行われる。 F-1-25

(26)

26

26

設定後の動作確認

以下の手順で、 テストページ、 設定ページを出力し、 接続機器と本機の接続および本機の 設定を確認する。 1) 接続機器の液晶表示部上のメインメニューから [ プリントサーバー ] を選択する。 2) [ プリントサーバーの状況 / 設定 ] ボタンを押す。 F-1-26 F-1-27 3) [ 機能 ] > [ ページの印刷 ] > [ テストページ ] および [ 設定ページ ] を選択する。 F-1-28 F-1-29

(27)

27

27

ネットワークへの接続

ネットワーク管理者にネットワークへの接続、 設定およびテストプリントを依頼する。 確認作業は、 取扱説明書の 「設定管理」 を参照して行う。

自動階調補正の実施

設置時には、 本体の自動階調補正を行う。 ・ 本体にカラーイメージリーダーが装着されている場合は、 「普通紙」 と 「厚紙 1 /厚紙 2」 と 「厚紙 3 /厚紙 4」 で自動階調補正 (フル補正) を必ず行うこと。 ・ 本体にカラーイメージリーダーが無い場合は、[ 設定 / 登録 ] > [ 調整 / メンテナンス ] > [ 画 質調整 ] > [ 自動階調補正 ] を実行する。 F-1-30

(28)

参照

関連したドキュメント

I give a proof of the theorem over any separably closed field F using ℓ-adic perverse sheaves.. My proof is different from the one of Mirkovi´c

Keywords: continuous time random walk, Brownian motion, collision time, skew Young tableaux, tandem queue.. AMS 2000 Subject Classification: Primary:

We present sufficient conditions for the existence of solutions to Neu- mann and periodic boundary-value problems for some class of quasilinear ordinary differential equations.. We

In Section 13, we discuss flagged Schur polynomials, vexillary and dominant permutations, and give a simple formula for the polynomials D w , for 312-avoiding permutations.. In

Analogs of this theorem were proved by Roitberg for nonregular elliptic boundary- value problems and for general elliptic systems of differential equations, the mod- ified scale of

Then it follows immediately from a suitable version of “Hensel’s Lemma” [cf., e.g., the argument of [4], Lemma 2.1] that S may be obtained, as the notation suggests, as the m A

The object of this paper is the uniqueness for a d -dimensional Fokker-Planck type equation with inhomogeneous (possibly degenerated) measurable not necessarily bounded

Correspondingly, the limiting sequence of metric spaces has a surpris- ingly simple description as a collection of random real trees (given below) in which certain pairs of