細則様式第1-2号

学位請求論文の内容の要旨

領 域

医療生命科学領域

分 野

放射線生命科学分野

氏 名 成田 将崇

(論文題目)

ACCUMULATED EXPOSURE DOSE OF MULTIPLE RADIOLOGICAL EXAMINATIONS AT AN EMERGENCY CENTER (救命救急センターにおける複数放射線検査の累積被ばく線量)

主 査 齋藤 陽子

副 査 高橋 康幸

副 査 野戸 結花

副 査 細川 洋一郎

The International Commission on Radiological Protection (ICRP) recommends that the exposure dose from radiological examinations should be as small as possible (as low as reasonably achievable, ALARA). However, some patients transported to the emergency center were subject to multiple radiological examinations such as mobile X-ray, computed tomography (CT) examination and angiography examination. We experienced the number of radiological examinations conducted at the emergency center over approximately 3 months, from July to September 2013. There were 50 CT cases in 302 total cases, and most examinations were plane head CT. There were 120 cases that received two imaging types using mobile X-ray and CT; 13 cases received mobile X-ray, CT, and angiography, which have a large radiation exposure dose.

Increased radiation exposure is a concern for patients. By inserting a thermoluminescent dosimeter (TLD) into a tissue-equivalent phantom, the equivalent dose and effective dose of each radiological examination were determined at each anatomical region. According to the total equivalent doses of radiological imaging (mobile X-ray, head to pelvis CT, head angiography), the lens equivalent dose was 30-56.99 mGy. This value is lower than the threshold (500 mGy) for cataract proposed in ICRP Publication 118. The head effective dose was 0.05 mSv for head mobile X-ray, 60.43 mSv for head to pelvis CT, and 8.42 mSv for head angiography. The total

(注)論文題目が外国語の場合は,和訳を付すこと。

(2)

【細則様式第1-2号続き】

effective dose was 68.9 mSv.

The results of this study, it is considered that there is a low possibility of radiation injury, there is a possibility that whole-body CT examination may be additionally performed, in which case the effective dose may exceed 100 mSv. In order to get maximal benefit and minimal harmful effects, it is necessary to examine appropriate imaging sections and imaging conditions when scanning.

To optimize ALARA measurements as well as the radiation dose, it is necessary

to know the exposure dose of radiological examination. The dose data evaluated in this

study will be useful for the estimation of radiation risks for patients of emergency

centers who undergo multiple radiation examinations.

(3)

【細則様式第1-2号続き】

(4)

【細則様式第1-2号続き】

学位論文のもととなる研究成果としての筆頭著者原著

論 文 題 目

ACCUMULATED EXPOSURE DOSE OF MULTIPLE RADIOLOGICAL EXAMINATIONS AT AN EMERGENCY CENTER

(救命救急センターにおける複数放射線検査の累積被ばく線量)

著 者 名 成田 将崇

掲載学術誌名 弘前医学

巻,号,項 第 68 巻第 2-4 号

掲載年月日 3 月 20 日

参照

関連したドキュメント

The notion of free product with amalgamation of groupoids in [16] strongly influenced Ronnie Brown to introduce in [5] the fundamental groupoid on a set of base points, and so to give

We describe a little the blow–ups of the phase portrait of the intricate point p given in Figure 5. Its first blow–up is given in Figure 6A. In it we see from the upper part of

Some new sufficient conditions are obtained for the existence of at least single or twin positive solutions by using Krasnosel’skii’s fixed point theorem and new sufficient conditions

I give a proof of the theorem over any separably closed field F using ℓ-adic perverse sheaves.. My proof is different from the one of Mirkovi´c

Bouziani, Rothe method for a mixed problem with an integral condition for the two-dimensional diffusion equation, Abstr.. Pao, Dynamics of reaction-diffusion equations with

[7] , On initial boundary value problem with Dirichlet integral conditions for a hyperbolic equation with the Bessel operator, J.. Bouziani

The object of this paper is the uniqueness for a d -dimensional Fokker-Planck type equation with inhomogeneous (possibly degenerated) measurable not necessarily bounded

While conducting an experiment regarding fetal move- ments as a result of Pulsed Wave Doppler (PWD) ultrasound, [8] we encountered the severe artifacts in the acquired image2.