• 検索結果がありません。

TK015N2 取扱説明書【英文】 資料|製品情報|東横化学株式会社 manual tk015n2 e

N/A
N/A
Protected

Academic year: 2018

シェア "TK015N2 取扱説明書【英文】 資料|製品情報|東横化学株式会社 manual tk015n2 e"

Copied!
5
0
0

読み込み中.... (全文を見る)

全文

(1)

LIQUID DETECTOR SENSOR

OPERATION MANUAL

for

TK-015N2

CE Mark Compliance

EN61326

TOYOKO KAGAKU CO., LTD.

Components Business Division

370 Ichinotsubo, Nakahara-Ku, Kawasaki-City, Kanagawa-Pref., JAPAN

Phone: (044)435-5860 Fax: (044)433-5332

(2)

Intro duc tio n

We appreciate that you evaluate our samples of the PNP outputs liquid detector sensor. ・Before you install or operate it, please read this operating manual thoroughly, and follow

the Instruction in order to avoid any accident, malfunction, defects, and hazards.

・Please keep this manual with good care as long as the sensor is operating.

Ta b le o f C o nte nts

1. Designation of Sensors・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3

2. Installation・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3

3. Wiring Instruction・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4

4. Adjustments・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5

(3)

1. Designation of the Sensor

TK-015N2

2

.Installation

Se nso r Bo dy

Tra nspa re nt Tub e Sa ddle Ba nd

Wing Nuts

You can simply install every sensor into a transparent tube, grasping the tube between Sensor Body and Saddle Band tightened by Wing Nuts.

CAUTION

(1) Be sure that the sensing surface (Light emission/reception window) and the tube surface must contact completely each other.

(2) Be aware that Saddle Band is so fragile that over-tightening with Wing Nuts may cause the crack of it.

(3) Recommend the torque for tightening will be approx. 2.5∼3.0kgf・cm, and avoid distortion

(4)

3.Wiring Instruction

(1) Generally 4-core cable is supplied with Sensor Body by 2-meter long, 3.8mm diameter.

Red : +24V power

White : Output 1(Liquid Existing – ON) Yellow : Output 2(Liquid Existing – OFF) Black : 0V power

(2) Connect the correct power source to Red and Black lines

CAUTION

Avoid wrong wiring for DC power. (Red line for PLUS polarity, and Black line for Minus.)

(3) Keep the load current not exceeding 50 mA. Otherwise, the output circuit of the sensor

may be destroyed.

NOTE : When you apply a relay as a load, add a diode into output connection in parallel configuration in order to limit the back electromotive voltage.

Refer to the sample chart below : relay BLAC K YELLO W WHITE RED +24V

O utp ut 1

O utp ut 2

-0V

Se nso r d io d e

+24V

-0V

DC Po we r

Note: The above wiring must be applied to the PNP Samples only.

(5)

4. Adjustments

Before starting this adjustment procedure, the tube must be empty, and follow the steps below :

①Install the sensor on the tube and apply the power into it, as followed by the foregoing

procedure. Remove Protection Cap, and turn a Sensitivity Adjusting Pot.(SAP) counter-clockwise(C-CW) using an adequate small driver. Indicating LED will become green.

②Next, turn a SAP clockwise(CW) slowly until Indicating LED have changed into red, then

stop turning.

③From the above position of SAP, again turn it, in the opposite direction, C-CW by approx

90 degree angle (one-quarter turn). Indicating LED shows now green. Now the adjustment has been completed.

5. Specifications TK-015N2

Power Source DC24V± 10%

Current Consumption 45mA below Tube O.D.(inch) 6∼25.4mm

Detecting Method Infrared Photoelectric Device

Output PNP Transistor Open Collector, max 50mA, 2 opposite signals Indicating LED Red: Liquid exist, Green: Liquid empty

Ambient Temperature -10℃∼60℃

Sensitivity Adjust Available (See above Section 4. for details)

Water Protection Available (Silicon stuffed-in), IP67 (IEC) equivalent

Body Material Poly-Carbonate

Cable 3.8m m O D, 4-w ire , 2 m

参照

関連したドキュメント

Jabra Talk 15 SE の操作は簡単です。ボタンを押す時間の長さ により、ヘッドセットの [ 応答 / 終了 ] ボタンはさまざまな機

P.17 VFFF VF穴あきフランジ P.18 VFBF VFブランクフランジ P.18 JISBNW

直流電圧に重畳した交流電圧では、交流電圧のみの実効値を測定する ACV-Ach ファンクショ

BIGIグループ 株式会社ビームス BEAMS 株式会社アダストリア 株式会社ユナイテッドアローズ JUNグループ 株式会社シップス

●  ボタンまたは  ボタンどちらかを押す。 上げる 冷房 暖房 下げる. 運転 暖房準備 冷房 暖房

三洋電機株式会社 住友電気工業株式会社 ソニー株式会社 株式会社東芝 日本電気株式会社 パナソニック株式会社 株式会社日立製作所

FLOW METER INF-M 型、FLOW SWITCH INF-MA 型の原理は面積式流量計と同一のシャ

東京電力パワーグリッド株式会社 東京都千代田区 東電タウンプランニング株式会社 東京都港区 東京電設サービス株式会社